LUX KONOzw Smart Hub Thermostat KN-ZW-WH1-B04 Manual

June 8, 2024
LUX

LUX

KONOzw Smart Hub Thermostat

SKU: KN-ZW-WH1-B04

Quickstart

This is a
secure
HVAC-Thermostat
for
U.S. / Canada / Mexico
.

Please make sure the internal battery is fully charged.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

KONOzw is the smart hub thermostat made with you in mind. It seamlessly connects to many smart hubs and blends in or stands out with its interchangeable Dcorsnap covers. KONOzw makes it easier than ever to personalize your comfort, dcor, and savings.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 5 Z-Wave Plus Lifeline

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: User Temperature Calibration

User Temperature Calibration. For example, sending a value of +50 means the calibration offset is +0.5F
Size: 2 Byte, Default Value: 0

SettingDescription

-250 – 250 Step-size = 10

Parameter 10: Temperature Limit – Cool Max

__
Size: 2 Byte, Default Value: 95

SettingDescription

60 – 95| Increment by 1F. The actual allowable range is dependent on the heat set point limit
---|---

Parameter 11: Temperature Limit – Cool Min

__
Size: 2 Byte, Default Value: 50

SettingDescription

50 – 75| Increment by 1F. The actual allowable range is dependent on the heat set point limit
---|---

Parameter 12: Temperature Minimum Setpoint Deadband

Temperature Minimum Setpoint Deadband. For example, setting the value to 200 means the deadband is +2.0F
Size: 2 Byte, Default Value: 200

SettingDescription

100 – 250 Step-size = 10

Parameter 14: Ambient Temperature Change Stepsize

Degree of change in ambient temperature in order to trigger the sending of temperature report
Size: 2 Byte, Default Value: 50

SettingDescription

50 0.5F
100 1.0F
150 1.5F
200 2.0F
250 2.5F
300 3.0F
350 3.5F
400 4.0F

Parameter 15: Regular Ambient Temperature Reporting Interval

Regular Ambient Temperature Reporting Interval
Size: 1 Byte, Default Value: 4

SettingDescription

1 – 24 1-24 hours

Parameter 16: Regular Operating State Reporting Interval

Regular Operating State Reporting Interval
Size: 1 Byte, Default Value: 4

SettingDescription

1 – 24 1-24 hours

Parameter 17: Command Echo Enable

Command Echo for- Thermostat Mode- Thermostat Fan mode- Thermostat Setpoint
Size: 1 Byte, Default Value: 0

SettingDescription

0 Disable
1 Enable

Parameter 2: Temperature Unit (C/F)

Temperature Unit (C/F)
Size: 1 Byte, Default Value: 1

SettingDescription

0 Celsius
1 Fahrenheit

Parameter 3: Available Control mode

Available Control mode
Size: 1 Byte, Default Value: 0

SettingDescription

0 Heat and Cool, Auto
1 Heat Only
2 Cool Only
3 Heat and Cool, no Auto
4 reserved

Parameter 4: System Type

__
Size: 1 Byte, Default Value: 0

SettingDescription

0 Furnace Gas
1 Furnace Electric
2 Heat Pump
3 Boiler no fan
4 reserved

Parameter 5: Reversal valve Type in Heat Pump

__
Size: 1 Byte, Default Value: 0

SettingDescription

0 O-valve
1 B-valve

Parameter 8: Temperature Limit – Heat Max

__
Size: 2 Byte, Default Value: 90

SettingDescription

60 – 90 Increment by 1F

Parameter 9: Temperature Limit – Heat Min

__
Size: 2 Byte, Default Value: 45

SettingDescription

45 – 60 Increment by 1F

Technical Data

Hardware Platform ZM5202
Device Type Thermostat – HVAC
Network Operation Always On Slave
Firmware Version HW: 2 FW: 1.00:00.114
Z-Wave Version 6.71.03
Certification ID ZC10-19076681
Z-Wave Product Id 0x0411.0x0001.0x2111
Thermostat Power Source
Sensors
Loads Controlled
Thermostat Modes
Color
Firmware Updatable
Thermostat HVAC Systems Supported
Supported Notification Types
Security V2 S2_UNAUTHENTICATED ,S2_AUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

  • Application Status
  • Association Grp Info
  • Association V2
  • Basic
  • Battery
  • Clock
  • Configuration
  • Device Reset Locally
  • Firmware Update Md V3
  • Manufacturer Specific
  • Notification V4
  • Powerlevel
  • Protection V2
  • Security
  • Security 2
  • Sensor Multilevel V7
  • Supervision
  • Thermostat Fan Mode
  • Thermostat Fan State
  • Thermostat Mode V2
  • Thermostat Operating State V2
  • Thermostat Setpoint V3
  • Transport Service V2
  • Version V2
  • Zwaveplus Info V2

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.