ZWAVE-SELECTION Heating thermostat ZWSEHT Manual

June 8, 2024
ZWAVE-SELECTION

ZWAVE-SELECTION

Heating thermostat

SKU: ZWSEHT

Quickstart

This is a ****

Thermostat
for
Europe
.

To run this device please connect it to your mains power supply.

To add this device to your network execute the following action:
In normal working interface, press & hold S4 to enter interface for inclusion of” Z-Wave network. Before device included into network, “- – -” will display on the screen. Then” press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID” will display on the screen in a few seconds.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.

Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This
device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message ( two- way
communication
) and every mains powered node can act as a repeater for other nodes
( meshed network ) in case the receiver is not in direct wireless range of the
transmitter.

This device and every other certified Z-Wave device can be used together with any other
certified Z-Wave device regardless of brand and origin
as long as both are suited for the
same frequency range.

If a device supports secure communication it will communicate with other devices
secure as long as this device provides the same or a higher level of security.
Otherwise it will automatically turn into a lower level of security to maintain
backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer
to www.z-wave.info.

Product Description

MCOHome Water Heating Thermostat is a Z-Wave enabled device for indoor” temperature control. MH7H-WH is mainly applied to control wall mounted boiler, water” valve/pump etc. The device is of high” reliability and practicability, which can be included and operated in any Z-Wave network with” other Z-Wave certified devices from any other manufacturers.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default
state.
Please make sure to reset the device into factory default. You can do this by
performing an Exclusion operation as described below in the manual. Every Z-Wave
controller is able to perform this operation however it is recommended to use the primary
controller of the previous network to make sure the very device is excluded properly
from this network.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country- specific
installation guidelines/norms may do works with mains power. Prior to the assembly of
the product, the voltage network has to be switched off and ensured against re-switching.

Installation

Step 1: Separate the device into two parts: the display” panel and the bottom.

Step 2: Insert all wires into the right terminals and” tighten screws. Wiring diagrams are shown below.

Step 3: Push the bottom into the junction box and” secure it with two screws, and then mount the touch” panel back.

Step 4: Confirm the device is well mounted, power on and it is ready to operate.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs
to be added to an existing wireless network to communicate with the devices of this network.
This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion.
Both processes are initiated by the primary controller of the Z-Wave network. This
controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is
then performed doing a special manual action right on the device.

Inclusion

In normal working interface, press & hold S4 to enter interface for inclusion of” Z-Wave network. Before device included into network, “- – -” will display on the screen. Then” press S4 once, device will enter learning mode to get a node ID. If inclusion is success, a node ID” will display on the screen in a few seconds.

Exclusion

In normal working interface, press & hold S4 to enter interface for exclusion of” Z-Wave network. Before device excluded into network, a node id will display on the screen. Then

press S4 once, device will enter learning mode to get a node ID. If inclusion is success, “- – -” will display on the screen in a few seconds.

Auto-Inclusion

Beside the standard inclusion this devices supports the so called auto inclusion.
Right after powering up the device remains in inclusion state and can be included by
(any) gateway without further actions on the device itself. The auto inclusion mode will
time out after some time.

Product Usage

On/Off operation

When power on, thermostat displays “OFF”,all outputs are forced off. Touch S3 button to” switch (manual/off/auto) mode, then press S2 to confirm and proceed power on/off setting. After” power on, device displays current week, local time, working mode, current temperature, output” status etc.

Note: After the backlit goes out, please press the button to light up the backlit first, then press the” button again for corresponding operation.

Temperature setting

In normal working status, press S4 or S5 button will enter into temperature setting interface.

The setting range is 5-37 ℃(41-99℉). Then press S4 or S5 can adjust the value. Press S3 or wait” 25 seconds without any key operation will save the setting and return back to the normal operation” interface.

Auto Mode: ” The changed value only valid in the current time period for this time, and” the device will not effect the preset time period value .

Manual Mode: ” The changed value will be valid until next setting.

Vacation Mode: ” The changed value will be valid until next setting.

Key lock function

In normal operating interface, long press S1+S4 button, icon appear that indicates the” button is locked, at this time all buttons are disabled; When long press S1+S4 button again,” icon disappear that indicates the button is unlocked, all buttons back to normal work.”

Control specifications

– Detection temperature < setting temperature – 0.5℃, output turns on, and output icon displays.”
– Detection temperature ≥ setting temperature + 0.5℃, output turns off, and output icon disappears.

Manual / Auto mode setting
In normal display interface, touch S3 button can switch between Manual and Auto mode.

Choose the mode you may need and press S2 button to save the setting.

Auto Mode: ” Device will follow the preset time periods and temperature to control heating” system automatically.

Manual Mode : Device will follow the manual setting temperature to control the heating system.

Vacation mode setting

– In normal working interface, if vocation mode is not activated, long press S2 button to enter” vacation mode temperature setting. The default temperature is 10 ℃, and setting range is” 5-37 ℃(41-98℉). Press S4 or S5 to adjust the value, then press S3 or wait 25 seconds to save” the setting and return to the normal working interface. In this time vacation mode icon” displays, and device will follow the setting.

– Long press S2 again will end vacation mode and resume to normal work, vacation mode icon

will be disappeared.

Local Time Setting

– In normal working interface, long press S1 to enter into local time setting interface.

– In local time setting interface, press S4 or S5 button to set the “week, hour & minute”” parameter, and press S1 button can switch among the “week, hour & minute”.

– After finish the local time setting, press S1 or wait 25 seconds without any key operation will” save the setting and return to normal display.

Auto Mode Time Periods Parameter Setting

– In normal working interface, short press S1 to enter into time periods setting. Four time” periods can be set for each day of the whole week.

– Press S2 can switch among “Hours, Minutes, Temperature value”. Press S4 or S5 can change” the value.

– After finished the setting of 4 time periods on Monday, press S1 and follow the same way to” set periods of next days.

– After all periods set, press S1 /S2 or wait 25 seconds without any key operation will save the” setting and return to normal display. Device will operate in accordance with the new setting.

The default setting is as follow:

High temperature protection

When external temperature sensor detect the temperature value≥55℃, device will open high” temperature protection, electric heating will be forced off, and high temperature protection icon” displays.

When external temperature sensor detect the temperature value<50 ℃, device will return to” normal work, high temperature protection icon disappears.

Anti-freeze protection function: (Optional)

In shutdown interface:

– When the built-in temperature sensor detect the temperature value≤5℃, device will open” anti-freeze protection, electric heating will be forced open, and anti-freeze protection icon displays.

– When the built-in temperature sensor detect the temperature value>8 ℃, device will turn” off anti-freeze protection and return to normal work, anti- freeze icon disappears.”
Note: ” If MH7 thermostat do not connect with an external temperature sensor, it will only display” the indoor temperature icon; If MH7 thermostat connect with an external temperature sensor, it” will display the indoor temperature and high temperature protection icon; When it is under high” temperature protection, high temperature protection icon flickers.

Humidity display operation

In normal working interface, long press S1+S5 buttons and enter into humidity display” interface, when press S1+S5 buttons again, it will back to the normal interface.

****

In shutdown state, long press S3+S5 synchronically can enter into secret menu. Press S4 or S5 to” enter code 1234. Touch S3 to enter setting interface. Following are parameters which can be set.

  • After power failure:

0 indicates device will be in shutdown state (“OFF”) when power on again;

1 indicates device will be in working interface when power on again;

2 (default) indicates device will stay the status before power failure when power on again.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association – one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device
controlling another device is called association. In order to control a different
device, the controlling device needs to maintain a list of devices that will receive
controlling commands. These lists are called association groups and they are always
related to certain events (e.g. button pressed, sensor triggers, …). In case
the event happens all devices stored in the respective association group will
receive the same wireless command wireless command, typically a ‘Basic Set’ Command.

Association Groups:

Group NumberMaximum NodesDescription

1 1 Lifeline
2 5 Switching relays
3 5 Switching relays

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however
certain configuration can adapt the function better to user needs or unlock further
enhanced features.

IMPORTANT: Controllers may only allow configuring
signed values. In order to set values in the range 128 … 255 the value sent in
the application shall be the desired value minus 256. For example: To set a
parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56.
In case of a two byte value the same logic applies: Values greater than 32768 may
needed to be given as negative values too.

Parameter 1: Upload temperature format automatically

__
Size: 1 Byte, Default Value: 2

SettingDescription

0 Celsius
1 Fahrenheit
2 Follow the main display

Parameter 2: Upload temperature and humidity automatically

__
Size: 1 Byte, Default Value: 3

SettingDescription

0 OFF
1 Upload the difference value only
2 Timing upload mode only
3 Upload the difference+timing upload mode

Parameter 3: Upload temperature difference

__
Size: 2 Byte, Default Value: 5

SettingDescription

3 – 1000 5*0.1℃=0.5℃, steps 0,1

Parameter 4: Upload time interval regularly

__
Size: 2 Byte, Default Value: 30

SettingDescription

10 – 65535 in seconds

Parameter 5: Upload humidity difference

When the detection humidity value differ with the last percentage value, uploading activated 2-255
Size: 2 Byte, Default Value: 3

SettingDescription

2 – 255 in %

Parameter 255: Factory setting

__
Size: 1 Byte, Default Value: 0

SettingDescription

85 Reset

Technical Data

Dimensions 86x86x42 mm
Weight 190 gr
Hardware Platform ZM5101
EAN 692895420707
IP Class IP 20
Voltage 230 V
Load 5a
Device Type Thermostat
Firmware Version 02.06
Z-Wave Version 04.21
Certification ID ZC10-18046084
Z-Wave Product Id 0x015f.0x0712.0x5102
Frequency Europe – 868,4 Mhz
Maximum transmission power 5 mW

Supported Command Classes

  • Basic
  • Sensor Multilevel
  • Thermostat Mode
  • Thermostat Operating State
  • Thermostat Setpoint
  • Association Grp Info
  • Device Reset Locally
  • Zwaveplus Info
  • Configuration
  • Manufacturer Specific
  • Powerlevel
  • Firmware Update Md
  • Association
  • Version
  • Time
  • Time Parameters

Explanation of Z-Wave specific terms

  • Controller — is a Z-Wave device with capabilities to manage the network.
    Controllers are typically Gateways,Remote Controls or battery operated wall controllers.

  • Slave — is a Z-Wave device without capabilities to manage the network.
    Slaves can be sensors, actuators and even remote controls.

  • Primary Controller — is the central organizer of the network. It must be
    a controller. There can be only one primary controller in a Z-Wave network.

  • Inclusion — is the process of adding new Z-Wave devices into a network.

  • Exclusion — is the process of removing Z-Wave devices from the network.

  • Association — is a control relationship between a controlling device and
    a controlled device.

  • Wakeup Notification — is a special wireless message issued by a Z-Wave
    device to announces that is able to communicate.

  • Node Information Frame — is a special wireless message issued by a
    Z-Wave device to announce its capabilities and functions.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals