BLAUBERG Company is happy to offer your attention a new generation product, the BLAUBERG Auto fan. The solid team of high-qualified professionals with many years of working experience, technological innovations in design and production, high-quality components and materials from the top worldwide producers have become the precondition for the best fan in its class.

INTRODUCTION

The present service instruction contains a technical description, technical data sheets, operation and mounting guidelines, safety precautions and warnings for safe and correct operation of the fan BLAUBERG Auto.
USE
The BLAUBERG Auto fan is designed for exhaust ventilation of residential and public premises heated during winter season. The fan is designed for wall or ceiling mounting (fig. 3-5). The fan is equipped with automatic shutters to prevent air back drafting during the fan standby.

COMPLETE SET

  • fan – 1 item;
  • screws and dowels – 4 items;
  • plastic screwdriver (for the models with timer) – 1 item;
  • service instruction;
  • packing box.

The fan design is regularly improved, so some models can slightly differ from those ones described in this service instruction.

BASIC CHARACTERISTICS

The fan designations, parameters, outer view, overall and connecting dimensions are shown in tables 1, 2, 3 and in fig. 1 and 2.
Table 1

Model| Max. air flow [m³ /h]| Power [W]| RPM [min-¹ ]| Noise level, 3 m [dBA]
---|---|---|---|---
Auto 100| 98| 18| 2300| 34
Auto 125| 185| 22| 2400| 35
Auto150| 295| 26| 2400| 39

Table 2

Model Switch Timer Humidity sensor Motion sensor
Auto ___
Auto ___ S
Auto ___ T  
Auto ___ ST  
Auto ___ H    
Auto ___ SH      
Auto ___ IR    

Switch (S) – built-in pull cord switch;
Timer (T) – turn-off time range from 2 to 30 min;
Humidity sensor (H) – humidity level range from 60% to 90%;
Motion sensor (IR) – reach distance from 1 to 4 m and sensor viewing angle up to 100°.
The fan does not cause interference with radio-, TV- or videoequipment.
Service life is not less than 5 years.BLAUBERG Ventilation Auto Series Wall
Exhaust Fan - Figure 1 Table 3

Model| Dimensions [mm]| Weight
[kg]
---|---|---
a| bl| b2| b3| c| d| e
Auto 100| 166| 150| 150| 150| 90| 100| 30| 0,56
Auto 125| 186| 128| 173| 174| 98| 125| 33| 0,73
Auto 150| 210| 150| 195| 196| 115| 150| 34| 0,9

Fig. 2BLAUBERG Ventilation Auto Series Wall Exhaust Fan - Figure
2

OPERATION RULES

The fan is rated for connection to 220…240 V / 50 Hz power mains and is designed for continuous operation always connected to power mains. The air motion direction in the system must match the pointer on the fan casing. The fan is rated for operation at ambient temperature from +1 °C up to +45 °C. The unit is rated as a Class II electrical appliance.
SAFETY RULES
All operations related to the fan electrical connections, servicing and repair works are allowed only after the fan disconnection from power mains. All mounting and servicing operations are allowed for duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user’s manual. The single-phase power grid must comply with the acting local electrical norms and standards. The fixed electrical wiring must be equipped with an automatic switch that is used for connection of the fan to power mains with gap on all poles at least 3 mm.
Make sure the impeller and the casing are not damaged before starting installation. The casing internals must be free of any foreign objects which can damage the impeller blades. Misuse of the product or any unauthorized modification are not allowed.
The product is not allowed for use by children and persons with reduced physical, mental or sensory capacities, without proper practical experience or expertise, unless they are controlled or instructed on the product operation by the person(s) responsible for their safety.
Supervise the children and do not let them play with the product. Take steps to prevent ingress of smoke, carbon monoxide and other combustion products into the room through open chimney flues or other fire-protection devices. Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting. The maximum permitted pressure difference per living units is 4 Pa. Operating medium must not contain any dust or other solid impurities, sticky substances or fibrous materials. The fan is not rated for operation in a media that contains hazardous or explosive materials and vapours, i.e. spirits, gasoline, insecticides, etc. Do not close or block the fan intake or exhaust vent not to disturb the natural air passage. Do not sit on the fan and do not put objects on the fan. Follow the guidelines of this service instructions to ensure durable operation of the product.

MOUNTING AND SETUP

The fan is designed for ceiling or wall mounting to extract air into a ventilation shaft or matching air duct of respective diameter (fig. 3-7).
The fan mounting sequence is shown in fig. 8-9. The fan wiring diagrams are shown in fig. 10-16. BLAUBERG Ventilation Auto Series Wall Exhaust Fan -
Figure 3BLAUBERG Ventilation
Auto Series Wall Exhaust Fan - Figure 4

WIRING DIAGRAMS AND FAN OPERATING LOGIC

BLAUBERG Ventilation Auto Series Wall Exhaust Fan - Figure
5S – external switch
QF – automatic circuit breakerBLAUBERG Ventilation Auto Series Wall Exhaust
Fan - Figure 6BLAUBERG Ventilation
Auto Series Wall Exhaust Fan - Figure 7S – external switch
QF – automatic circuit breakerBLAUBERG Ventilation Auto Series Wall Exhaust
Fan - Figure 8BLAUBERG Ventilation
Auto Series Wall Exhaust Fan - Figure 9S – external switch
QF – automatic circuit breakerBLAUBERG Ventilation Auto Series Wall Exhaust
Fan - Figure 10BLAUBERG Ventilation
Auto Series Wall Exhaust Fan - Figure 11QF – automatic circuit breaker
BLAUBERG Ventilation Auto Series Wall Exhaust Fan - Figure
12BLAUBERG Ventilation Auto Series Wall
Exhaust Fan - Figure 13 Warning!
The timer circuit is under mains voltage! Disconnect the fan from power mains prior to any adjustment operations.
The fan delivery set includes a specially designed plastic screwdriver for fan settings adjustments. Use the screwdriver to alter the turnoff delay time threshold.
Do not use a screwdriver, knife, etc. for adjustment operations not to damage the circuit board. BLAUBERG Ventilation Auto Series Wall Exhaust
Fan - Figure 14

MAINTENANCE

Any servicing and maintenance operations of the fan are allowed after it is disconnected from power mains only. Maintenance means regular cleaning of the fan surfaces from dirt and dust. To clean the fan, wipe its surfaces with a cloth wetted in a mild soap solution, then wipe the surfaces dry. Avoid water dripping on the motor and circuit board!
STORAGE AND TRANSPORTATION RULES
The unit can be carried in the original packing by any mode of transport provided proper protection against precipitation and mechanical damage.
Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °С to +40 °С and relative humidity up to 80 %.The storage environment must be free of dust, acid or alkali vapours to prevent corrosion.
THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE IT AS UNSORTED DOMESTIC WASTE.
MANUFACTURER’S WARRANTY
The fan complies with the requirements according to the EU norms and directives, to the relevant EU-Low Voltage Equipment Directives, EU-Directives on Electromagnetic Compatibility.
We hereby declare that the following product complies with the essential protection requirements of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council and Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC on the approximation of the laws of the Member States relating to electromagnetic compatibility. This certificate is issued following test carried out on samples of the product referred to above. Assessment of compliance of the product with the requirements relating to electromagnetic compatibility was based on the following standards.Protection degree index according to IP rating against access to hazardous parts and water ingress – IP24.
The manufacturer hereby warrants normal operation of the fan over the period of five years from the retail sale date provided observance of the installation and operation regulations. In case of failure due to faulty equipment during the warranty period the consumer has the right to exchange it.
Warning! To replace the unit, the user must provide the user’s manual with the purchase date stamp and the payment paperwork certifying the purchase. In case of no confirmation of the sale date, the warranty period shall be calculated from the manufacturing date.
By purchasing this product the customer confirms to have read and agreed to the terms, rules and requirements related to operation, storage, transportation, mounting, adjustment, connection, maintenance and repair as well as warranty obligations with respect to this product as set forth in the manufacturer’s accompanying documentation to the product.

Model is recognized as serviceable.
SALES DATE
MANUFACTURED ON (DATE):
SOLD
APPROVAL MARK
AUTO_EN-03

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BLAUBERG Ventilation User Manuals

Related Manuals