swim fun 1295 Heat Splasher Pool Heat Pump User Manual

June 9, 2024
swim fun

swim fun 1295 Heat Splasher Pool Heat Pump- USER MANUAL
Heat Splasher Pool Heat Pump
2.5 kW (Art. 1295) . 4.2 kW (Art. 1296) . 5.5 kW (1297)

1295 Heat Splasher Pool Heat Pump

Pure bathing pleasure

Swim & Fun Scandinavia offer water care products and pool accessories for all pool sizes. Choose between multi-products such as our EasyPool disposable dispenser that keeps the water clean and inviting, even when you are not at home. Or try the practical chlorine-free CombiTabs that are easily added to the water via a floating dispenser or directly into the skimmer.
Do you prefer to dose the water care products separately, they can all be purchased individually in practical 1 l / 1 kg tubs – all with childproof caps and detailed instructions. In that case, we recommend the practical spoon with built-in weight. Keep in mind: successful water care is based on a balanced pH level. The water must be neutral (value between 7.0 and 7.4). You can easily test the water’s pH level with Swim & Fun Test Strips. If the value is below 7.0 raise with pH Plus. If above 7.4 lower with pH Minus. Besides pools, sand filter systems and basic pool accessories Swim & Fun offer many opportunities to make the bathing experience even better: Outdoor solar showers, Sun heaters, LED pool lamps and much more.

swim fun 1295 Heat Splasher Pool Heat Pump-fig1

Visitswim-fun.com and learn more about pool care.

swim fun 1295 Heat Splasher Pool Heat Pump-fig2

AUTOMATIC PH TESTING AND REGULATION
Easy pH tester that automatically regulates the pH balance in the pool water. The water pH changes constantly and affects: The disinfection efficiency (at a pH of 8 the effectiveness is for example only 25%). Swimming comfort (eye irritation, drying of the skin, the smell and taste of chlorine) The water quality (corrosion or calcium buildup, cloudy water). Easy pH takes up almost no space and is easy to install.
SALT/CHLORINE GENERATOR FOR SMALL GARDEN POOLS
Easy Salt is good for the environment and at the same time ensures clean bathing water. With Easy Salt it is easy to keep bathing water clean and clear. Easy Salt is a salt chlorinator, which is simply a machine that uses electrolysis to turn salt into chlorine.
COVERS
There are pool covers for various purposes. A standard pool cover that prevents dirt in the water. A summer cover with thermo function will help maintain the tem- perature of the bath water during the season, and is a must if you have solar heaters or heat pumps connected to your pool. A winter cover, or all-season cover, with wire lock provides security and protects against evaporation. At the same time it prevents sunlight to enter the pool, which can cause increased algae development. And last but not least, a ground cover under the pool protects the liner from sharp elements.

swim fun 1295 Heat Splasher Pool Heat Pump-fig3

FILTERBALLS GIVES YOU CRYSTAL-CLEAR POOL WATER
Filterballs have a superior filtering effect compared to normal filter sand or loose cartridge filters. Filterballs form an effective filter layer that adapts to the shape of any filter and catches suspended particles in the water down to 10 micrometres. (Filter sand catches suspended particles down to 40-50 micrometres.) Filterballs are also much easier to handle – 700 grammes of Filterballs replace 25 kg of filter sand. Read more at swim-fun.com and find your nearest distributor.

Thank you for choosing a Heat Splasher to heat your pool. It will heat the pool water, and maintain a constant temperature when the ambient air temperature is over 12°C
The performance of the heat pump will always be good, provided that the following elements are present:

  1. Fresh airswim fun -icon

  2. Electricity

  3. Swimming pool water

Responsible Disposal

This symbol indicates that this product should not be disposed of with general household waste. This applies throughout the entire EU. In order to prevent any harm to the environment or health hazards caused by incorrect waste disposal, the product must be handed in for recycling so that the material can be disposed of in a responsible manner. When recycling your product, take it to your local collection facility or contact the place of purchase. They will ensure that the product is disposed of in an environmentally sound manner.

Safety information

Please read these instructions thoroughly before using the heat pump and save them for future reference:

  1. The heat pump must always be turned off when the filter pump is turned off. Alternatively, they can be turned off at the same time from the same switch.
  2. Always store the unit upright. If the unit has been tilted or laid on its side, you must wait 24 hours before turning on the heat pump.
  3. Place the unit on a flat, solid base.
  4. Do not drop the heat pump.
  5. The heat pump must ALWAYS be installed outdoors.
  6. Make sure that the RCD voltage setting in the heat pump corresponds to the local mains voltage before you connect the device.
  7. Do not use unnecessary force to pull the mains plug out. The power cord must not be wound around the heat pump.
  8. Do not use the heat pump in combination with a transformer, as this may cause dangerous situations.
  9. If the heat pump is damaged during transport, it must be replaced. Contact your service centre or a qualified professional in order to avoid any risk.
  10. Always make sure that the water is properly connected to the heat pump, before you start using the unit.
  11. Do not insert objects directly into the fan, when the heat pump is in operation, as this will block the heat pump and cause damage.
  12. The evaporator fins must not become damaged.
  13. This heat pump is not intended for use by anyone who has impaired physical, sensory or mental capacity or anyone who lacks the required experience and knowledge, except under supervision or after training in the use of the device by a person, who is also responsible for their safety.
  14. Keep a watchful eye on children: Never allow children to play with the heat pump.
  15. The heat pump will not run at temperatures at or below +12 °C.
  16. Take the plug out of the socket when the heat pump is not in use and before cleaning.
  17. The heat pump must be drained of water and stored indoors during the winter. Otherwise the heat the pump may become damaged. The warranty is voided by frost damage.
  18. The heat pump contains R32 gas, which can only be refilled by a licensed operator.

Specifications

3.1 Technical data for pool heat pumps

Model 1295 1296 1297

Air 28°C, Water 28°C, humidity 80%
Heat Output (kW)| kW| 2.5| 4.2| 5.5
Power consumption (kW)| kW| 0.59| 1| 1.31
COP| | 4.2| 4.2| 4.2
Air 15°C, Water 26°C, humidity 70%
Heat Output (kW)| kW| 1.9| 3.2| 4.2
Power consumption (kW)| kW| 0.56| 0.91| 1.2
COP| | 3.4| 3.5| 3.5
Voltage| | 220-240V~50Hz/1PH
Rated Current| A| 2.6| 4.4| 5.8
Fuse current| A| 7.5| 13| 16
Maximum pool size

(with pool thermal cover)

| m³| 10| 12| 14
Recommended pool size (with pool thermal cover)| m³| 0-6| 6-10| 9-12
Recommended water flow| m3/h| 2| 2| 2.5-3.2
Water pressure drop| KPa| 15| 15| 15
Condenser| | Titanium heat exchanger in PVC
Water pipe in-out| 50 mm| 38/32
Fan speed| RPM| 2100| 1,100| 1,100
Sound level (10 m)| dB(A)| 48| 46| 46
Sound level (1 m)| dB(A)| 57| 55| 55
Refrigerant type| | R32
Refrigerant quantity| g| 150| 280| 550
Net weight| kg| 18| 26| 28
Gross weight| kg| 20| 28.5| 31
Net dimensions| 50 mm| 310 x 356.5 x 365| 434 x 432.5 x 460| 434 x 432.5 x 460
Gross dimensions| 50 mm| 400 x 455 x 450| 515 x 515 x 540| 515 x 515 x 540

The above may be corrected without warning.

Preparation, installation and connection

4.1 Preparation
The heat pump must be placed on a flat and dry place, for example on some tiles.
The heat pump must always be kept vertical with the display facing up. Do not turn the heat pump on for 24 hours after it has been transported or tilted.
Pool hose (art. 1582 or 1542) and clamps (art. 1524) not included.
If the water flow from the pool pump is greater than what is allowed
Install a bypass (Bypass Kit art. 1572) if the water flow from the pool pump is more than 20% greater than the maximum allowed flow through the heat pump’s heat exchanger.

The following things must be present in order for the heat pump to operate correctly.

  • Fresh air
  • Electric current
  • Pool filter system with circulation pump
  • Water in the pool
    The unit can be installed at almost any outdoor location, as long as the specified minimum distance to other objects is complied with (see drawing below).

4.2 Location
The heat pump must be placed at least 2 metres away from the pool.

swim fun 1295 Heat Splasher Pool Heat Pump-fig5

4.3 Set-up

swim fun 1295 Heat Splasher Pool Heat Pump-fig6

4.4 The fitting of accessories
Comes with:
4 Pre-installed anti-vibration pads – A
1 Drainage diverter – B
1 Drain hose (1m) – C
Drain the condensate by installing the drain diverter (B) together with the drain hose (C). Helps preventing icing and damage of the heat exchanger.
IMPORTANT! Raise the heat pump. If you tip it over or turn it, you can damage the compressor.

4.5 Electrical connection
Before the heat pump is connected, check that the power supply matches the operating current of the heat pump. The heat pump is supplied with an RCD integrated mains plug, which provide electrical protection.
NOTE
The heat pump has no pump. In order to be able to heat the water, the filter pump must be in operation. It is the filter pump that directs the water through the heat pump and the Heat Splasher cannot start if the water is not circulating.

4.6 Initial procedure
When everything is connected and has been checked, go through the following points:

  • Turn on the filter pump. Check for leaks and make sure that the water is flowing to and from the pool.
  • Connect the power to the heat pump. The unit will start when the time delay has expired.
  • After a few minutes, check if the air that is being blown out of the unit is cooler.
  • Check that the heat pump stops automatically when the filter pump is switched off.

4.7 Time delay
In order to protect the electrical circuit, the heat pump has a built in 3-minute start-up delay. This is also in order to avoid excessive wear and tear of switches. The unit starts
automatically when the time delay has expired. Even a short power outage will trigger the start-up delay and prevent the device restarting immediately. Further power cuts within the same 3-minute period will not further extend the start-up delay.

NOTE
The heat pump must be earthed. We recommend the purchase of a Schuko plug.

Instructions for use

5.1. Control buttons on the LED panel

When the heat pump is in operation the LED display shows the water inlet temperature.
LED 1 is lit when the compressor is in operation.
LED 2 is lit when there is a fault.
5.2. Turn the heat pump on/off

Press to turn on the heat pump. The LED display shows the set water temperature for 5 seconds, and then changes to show the current water inlet temperature.
Press again to switch off the heat pump.
Please note that the heat pump start-up time can be up to 3 minutes.
5.3. Setting the water outlet temperature

Press or to adjust the water outlet temperature (interval: 10-42 °C).
Press to save the settings and exit the menu.
5.4. Parameter control

Parameter Code Interval Note
Ambient temperature d0 0—99 Will flash and display oU if outside

interval
Water temperature| d1| 0—99| Will flash and display oU if outside interval

Press to access the parameter control. Press or to select code d0/d1.
Press again and the measured value will be displayed.
Press to save and exit the menu.

Maintenance

  • You should regularly check the water supply system in order to prevent air getting into the system which can reduce the water flow, as it will reduce the performance and stability of the heat pump.
  • Clean the pool/hot tub and filter system on a regular basis in order to avoid damage to the device resulting from a dirty and clogged filter.
  • You must empty the water from the heat exchanger if the heat pump is taken out of operation for a longer period of time, and especially during the winter season.
  • When the heat pump is being prepared for winter storage it is recommended to cover the heat pump to or keep it indoors where it will be protected from frost.
  • At startup, make sure that the system is fully filled with water before the unit is switched on.
  • In normal operation, the air being sucked in will be cooled and water can/will condense on the ribs of the evaporator and run out of the base of the unit. It is quite normal that there will be condensation from the heat pump. It is not a leak or a fault with the device. High humidity can lead to several litres of water being condensed per day.
  • The refilling of gas must be performed by a professional with an R32 operating license.

Troubleshooting

Fault condition Code Reason Solution
Low air temperature pro- tection P0 Air temperature is too low Can only be

used when the air temperature rises above 12 °C
Water temperature sensor error| P1| Water temperature sensor open circuit or short circuit.| Water temperature sensor needs to be replaced. Contact dealer
Air temperature sensor error| P2| Air temperature sensor open circuit or short circuit.| Air temperature sensor needs to be replaced. Contact dealer.
Low pressure switch alarm| EL| Low pressure switch disconnected| Contact dealer

7.1 Electrical circuit
Wiring diagrams
swim fun 1295 Heat Splasher Pool Heat Pump-
fig9

NOTE
The electrical wiring diagram is only for general reference.
The heat pump must always be connected to an effective earth wire on the connection clamp marked in the diagram. The earth connection prevents the conductive parts of the heat pump becoming accidentally energised. An ineffective earth can lead to personal injury.
The heat pump must have a splash-proof switch located beside it. This makes it possible to interrupt the electrical supply to the heat pump when servicing or when the heat pump is taken out of operation.
If you are in any doubt as to whether the earth is effective, contact your electrical installer.

7.2. Exploded view of 1295

Heat pump 1295

No.| Part name| No.| Part name
1| Top cover| 15| Front panel
2| Pillar| 16| Base
3| Ambient temp. sensor| 17| Titanium exchanger
4| Copper pipe| 18| Copper pipe
5| Exhaust pipe| 19| Water in temp. sensor
6| Capillary| 20| N/A
7| Electric box| 21| Gas collecting pipe
8| Compressor capacitance Clip| 22| N/A
9| Compressor capacitance| 23| N/A
10| Fan motor top plate| 24| Gas return piping
11| Controller| 25| Low pressure switch
12| Front grill| 26| N/A
13| Power cord buckle| 27| Compressor
14| Fan motor assembly| 28| Evaporator

swim fun 1295 Heat Splasher Pool Heat Pump-fig10

7.3. Exploded view of 1296 and 1297

Heat pump 1296 and 1297

No.| Part name| No.| Part name
1| Pillar| 16| Power cord buckle
2| Top cover| 17| Base
3| Exhaust pipe| 18| Titanium exchanger
4| Ambient temp. sensor| 19| Water in temp. sensor
5| Electric box| 20| N/A
6| Fan capacitor| 21| Gas collecting pipe
7| Capillary| 22| N/A
8| Controller| 23| N/A
9| Copper pipe| 24| N/A
10| Compressor capacitance clip| 25| Low pressure switch
11| Compressor capacitance| 26| Compressor
12| Front panel assemble| 27| Gas return piping
13| Fan motor| 28| Copper pipe
14| Fan blade| 29| Evaporator
15| Front grill| |

swim fun 1295 Heat Splasher Pool Heat Pump-fig11

Service

If you have any questions or need more information, please feel free to call Swim & Fun Scandinavia customer service on + 45 7022 6856.
If you need service or to make a warranty claim, you must create a case directly in our support system by clicking on www.swim- fun.com/SUPPORT
We have specialist knowledge of our products and the field in general, so you can get help quickly and easily.

Warranty

Limited warranty
We guarantee that all parts are free of defects in materials and workmanship for a period of two years from the date of purchase. The warranty covers only material or manufacturing defects that prevent the product from being able to be installed or operated in a normal way. Defective parts will be replaced or repaired. The warranty does not cover transportation damage, any use other than what is intended, damage caused by incorrect assembly or improper use, damage caused by impact or other error, damage caused by frost cracking or by improper storage. The warranty becomes void if the user modifies the product. The warranty does not include product-related damage, property damage or general operational loss. The warranty is limited to the initial retail purchase and cannot be transferred and it does not apply to products moved from their original location. The manufacturer’s liability cannot exceed the repair or replacement of defective parts and does not include labour costs to remove and reinstall the defective part, transportation costs to and from the service centre, and all other materials necessary to carry out the repair.

This warranty does not cover failure or malfunction as a result of the following:

  • Lack of proper installation, operation or maintenance of the unit in accordance with our published “User’s Guide” supplied with the unit.

  • The workmanship of any installation of the unit.

  • Not maintaining a proper chemical balance in your pool [pH level between 7.0 and 7.4.
    Free chlorine between 0.5 – 1.5 mg/l. Total dissolved solids (TDS) less than 1,200 ppm. Salt maximum 8 g/l]

  • Misuse, alteration, accident, fire, flood, lightning strike, rodents, insects, negligence or unforeseen actions.

  • Scaling, freezing up or other conditions that cause insufficient water circulation.

  • Operation of the device without complying with the published minimum and maximum flow specifications.

  • Use of non-factory authorised parts or accessories in conjunction with the product.

  • Chemical contamination of combustion air or improper use of water care products, such as the supply of water care products upstream of the heater and the hose or through the skimmer.

  • Overheating, improper wiring, improper power supply, indirect damage caused by the failure of O-rings, sand filters or cartridge filters, or damage caused by running the pump with inadequate amounts of water.

Limitation of liability
This is the only warranty provided by the manufacturer. No one is authorised to make any other warranties on our behalf.
This warranty is in lieu of all other warranties, expressed or implied, including but not limited to any implied warranty of fitness for a particular purpose and saleability.
We expressly disclaim all liability for consequential damage, accidental damage, indirect loss or loss related to a breach of the expressed or implied warranty.
This warranty gives you specific legal rights, which may vary by country.
Complaints
In the event of any warranty claim a valid purchase receipt must be presented.

Customer service:
swim-fun.com/support
Danmark +45 7022 6856
Sverige +46 771 188819
© All rights reserved Swim & Fun A/S 2022
Swim & Fun A/S
Ledreborg Allé 128 K, DK-4000 Roskilde
info@swim-fun.com . www.swim-fun.com
MV-1295-1296-1297-Heat-Splasher-MANUAL-BOOK.indb
06-04-2022 13:08:45

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals