OLIPTEK DMX512 Master Controller Lighting Portal Instruction Manual
- June 3, 2024
- OLIPTEK
Table of Contents
OLIPTEK DMX512 Master Controller Lighting Portal Instruction Manual
Important: Read All Instructions Prior to Installation
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
PRODUCT DESCRIPTION & PARAMETERS
PRODUCT DESCRIPTION
- The DMX512 control panel is a master controller designed to control the DMX decoders.
- It can control 512 DMX channels.
- It enables to configure max. 16 groups or zones with max. 8 scenes, 24 time schedules and 8 cycle schedules configured to each group.
- The panel supports 5 different types of DMX load: Dim, CCT, RGB, RGBW, RGB+CCT.
- 5 years warranty
ELECTRIC PARAMETERS
Output Signal
|
DMX512 signal
---|---
Power Supply
|
100-240VAC
Power consumption
|
< 15 mA
Operating temperature
|
0-40°C
Relative humidity
|
8% to 80%
Dimensions|
86x86x41mm
WIRING DIAGRAM
OPERATIONS
KEY FUNCTION DEFINITION & DESCRIPTION
Layout of Panel Keys (EU Size)
Key Function Definition (EU Size)
FRONT SIDE
BACK SIDE
OPERATION INSTRUCTION
LOCK & UNLOCK THE PANEL
**Figure 1
Unlock The Panel:
**As shown in following Figure 2, there is a lock icon at the top right corner
of the display, which means the panel is locked. Press and hold both Up key
and Down key for approximate 1 second, the panel will be unlocked, the lock
icon will disappear, the display will show Group information page.
Lock The Pane l:
Lock the panel automatically, after the panel is powered on or panel keys to
be locked, the panel is under unlocked status, if automatic lock function is
enabled, when the lock time elapses, and there is no operation of the keys,
the panel will be locked.
Lock the panel manually, under unlocked status, press and hold both Up key and Down key for approximate 1 second, the panel will be locked.
LIGHTING CONTROL
On/Off Key:
Under unlocked status, short press On/Off key, if any lighting devices in
current Group is on, all lighting devices in current Group will be turned off,
if lighting devices in current Group is off, all lighting devices in current
Group will be turned on.
Scene Keys:
Short press a scene key, the lighting devices in current Group will go to the
configured scene parameters. There are total 1-8 scene keys, which means 8
scenes for each Group. Corresponding LED will indicate the loads’ on/off
status.
FUNCTION DESCRIPTION
GROUP STATUS INFORMATION PAGE
**Menu Items’ Definition
Figure 2**
Current Group status information page is as shown in following Figure 3, the menu items definitions are as follows:
- G01: Current group is Group 1
- Zone01: Current group name
- RGBCCT: Current group mode is RGBCCT mode
- Brightness: Current group brightness percentage
- R: Current group red color value
- G: Current group green color value
- B: Current group blue color value
- CCT: Current group color temperature value
Page Operation
Parameter Selection:
Short press Up key or Down key to select a parameter. When the parameter
font color is black and background color is white, the parameter is selected.
Parameter Value Modification :
Fig 4
If a selected parameter item is an attribute of lighting devices, short press
Plus key + or Minus key – to increase or decrease parameter value of the
selected parameter. Press and hold Plus key + or Minus key – to pop up a
window of selected parameter and increase or decrease parameter value
continuously. As shown in following Figure 4. Release the key, the pop-up
window will be closed automatically after 5 seconds, also the pop-up window
can be closed by short pressing the Back key .
Switch to Another Group or Zone :
If the selected parameter item is Group information, short press Plus key + or
Minus key – to switch to another different group or zone.
Parameter Preview & Save:
Short press Confirm key , lighting devices in current group will go to the
modified group parameters’ value. Press and hold Scene keys (1-8) to save the
current parameters’ value as the group’s corresponding scene. Once saved
successfully, the blank area of the display will show “OK”.
Page Switch:
Short press Back key ****to switch to Group configuration page, short press
Back key again to switch to
Group status information page. The Group configuration page and Group status
information page can be
switched alternately by operate the Back key .
GROUP CONFIGURATION FUNCTION
Fig 5
Fig 6
Short press Back key to switch to Group configuration function page. Page 1 of Group configuration page is as shown in following Figure 5, short press Up key or Down key to switch setting of different functions, Page 2 of Group configuration page is as shown in following Figure 6. There are total 5 different functions can be set. Tick a function to select it and then short press Confirm key to enter into the function setting page of selected item.
On Group configuration function page (Figure 5/Figure 6), operate Plus key + or Minus key – to switch current group to another.
Group Mode Setting
**Enter into Group Mode Setting Page
** Fig 7
Enter into Group configuration function page as shown in Figure 5 and Figure
6, short press Up key or Down key to select “1.Control Mode”, short press
Confirm key to enter into Group Mode setting page as shown in following Figure
7.
Mode Modification
Short press Up key /Down key or Plus key +/Minus key – to modify current mode,
the mode with black font color and white background color is current selected
mode. There are 5 different modes available. (Dim, CCT, RGB, RGBW, RGBCCT)
Mode Saving
Short press Confirm key to confirm and save the modified mode. The blank area
of the display will show “Save OK” which means the mode is saved. Short press
Back key to return to Group configuration page.
Group Address Range Setting
Enter into Group Address Range Setting Page
Fig 8
Enter into Group configuration function page as shown in Figure 5 and Figure
6, short press Up key /Down key to select “2.Address Range”, short press
Confirm key to enter into Group address range setting page as shown in
following Figure 8.
Group Address Parameter Items Selection
There are 3 parameter items which can be modified for Group Address: start
address, end address, clear. Short
press Up key /Down key to switch and select a parameter item. The parameter
item with black font
color and white background color is selected.
Group Address Modification
Short press Plus key + /Minus key- to modify the selected parameter item,
address range available for modification is 1-512. If “Clear” parameter item
is selected, short press Confirm key to execute clear address range function,
once cleared, the start address and end address are both 0.
Notes:
- Address range of any group shall be within 1-512
- Start address of any group shall not exceed end address.
- Address range of current group shall be a multiple of the output channel quantity of current selected control mode.
- Address range of different groups shall not cross and repeat.
Group Address Saving
Short press Confirm key to save modified address parameters of current group.
Short press Back key to return to Group configuration page.
Time Schedule Setting:
Time Schedule Introduction:
Time Schedule is a timing task, each group has 24 timing tasks, when “date” or
“week” is selected and current timing task is enabled, when real time is the
sames as the scheduled task time, the lighting devices in the group will go to
the parameters set under the timing task.
There are two types of time schedule:
- Non-repeated time schedule based on a detailed date
- Repeated time schedule based on week period
Enter into Time Schedule Setting Page
Enter into Group configuration function page as shown in Figure 5 and Figure
6, short press Up key /Down key to select “3.Time Schedule”, short press
Confirm key to enter into Group Time Schedule setting page as shown in
following Figure 9 to Figure 16.
Time Schedule Parameter Items Selection
Short press Up key /Down key to switch and select the parameter items, the
parameter item with underline is selected
Time Schedule Parameter Items Introduction:
Time schedule type: non-repeated time schedule (date):
Assume current group with control mode RGBCCT as an example to introduce the
parameter items as shown in Figure 9 to Figure 12. (Parameter items are
different due to different control modes.)
Fig 9
Fig 10
Fig 11
Fig 12
- “1.Time Schedule”is serial number of a timing task, there are total 24 timing tasks, modification range is 1-24.
- “2.Timer Type”is the type of the timing task, which has two types “week” and “date”
- “3.Time” is the scheduled time of the task (Hour:Minute:Second)
- “4.Date” is the detailed date (Date-Month-Year) of the timing task when type “date” Timer Type is selected
- “5.Call Cycle Task” is the switch for time schedule to recall corresponding cycle task, “YES” means enabled, “NO” means disabled. “Cycle Number” is the serial number of the cycle task to be recalled, modification range is 1-8, current default is to recall Cycle number=1, others are for future extension.
- ‘6.Brightness” is the brightness percentage of the group, modification range is 0-100.
- “7.Color” is the RGB values of the group, modification range is 0-255.
- “8.CCT” is the CCT value of the group, modification range please refer to system parameter setting 3.3.3 CCT Range.
- “9.Enable” is the function to enable or disable current timing task, “YES” means enable, “NO” means disable.
- “10. All Enable” is to enable or disable all timing tasks of current group, “YES” means enable, “NO” means disable.
- “11.Single View” is to preview current timing task.
- “12.Multiple View” is to preview all timing tasks enable or disable status in current group, “YES” means enable, “NO” means disable
Time schedule type: repeated time schedule (week)
Assume current group with control mode RGBCCT as an example to introduce
the parameter items as shown in Figure 13 to Figure 16. (Parameter items are
different due to different control modes.)
Fig 13
Fig 14
Fig 15
Fig 16
- “1.Time Schedule” is serial number of a time task, there are total 24 time tasks, modification range is 1-24.
- “2.Timer Type”is the time type of the timing task, which has two types “week” and “date”
- “3.Time” is the scheduled time of the task (Hour:Minute:Second)
- “4.Week” is the week (Monday to Sunday) of the timing task when type “week” Timer Type is selected, when corresponding week shows black font color and white background, the week is activated as the cycle week of the timing task.
- “5.Call Cycle Task” is the switch for time schedule to recall corresponding cycle task, “YES” means enabled, “NO” means disabled. “Cycle Number” is the serial number of the cycle task to be recalled, modification range is 1-8, current default is to recall Cycle number=1, others are for future extension.
- “6.Brightness” is the brightness percentage of the group, modification range is 0-100.
- “7.Color” is the RGB values of the group, modification range is 0-255.
- “8.CCT” is the CCT value of the group, modification range please refer to system parameter setting 3.3.3 CCT Range.
- “9.Enable” is the function to enable or disable current timing task, “YES” means enable, “NO” means disable.
- “10. All Enable” is to enable or disable all timing tasks of current group, “YES” means enable, “NO” means disable.
- “11.Single View” is to preview current timing task.
- “12.Multiple View” is to preview all timing tasks enable or disable status in current group, “YES” means enable, “NO” means disable.
Time Schedule Parameter Value Modification
Short press Plus key + /Minus key – to modify current selected parameter item
value. Press and hold Plus key + /Minus key – to increase/decrease value
rapidly.
Once any parameter item is selected, press and hold On/Off key , meanwhile after approximate 1 second, short press Plus key + /Minus key – to switch the serial number of the time schedules.
Time Schedule Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “OK” to indicate saving successfully.
Short press Back key to return to group configuration page.
Cycle Schedule Setting:
Cycle Schedule Introduction:
Cycle Schedule is a periodical cycle action, each group has 1 periodical cycle
action, which includes 8 steps (you can program max. 8 colors for the cycle
action), when corresponding periodical cycle action is activated, the lighting
devices in the group will turn on based on the time setting parameters “Stay
Time” and “Fade Time” of the cycle action.
Enter into Cycle Schedule Setting Page
Enter into Group configuration function page as shown in Figure 5 and Figure
6, short press Up key /Down key to select “4.Cycle Schedule”, short press
Confirm key to enter into Cycle Schedule setting page as shown in following
Figure 17 to Figure 19.
Fig 17
Fig 18
Fig 19
Cycle Schedule Parameter Items Selection
Short press Up key /Down key to switch and select a parameter item. The item
with underline is selected.
Cycle Schedule Parameters Introduction:
Assume current group with control mode RGBCCT as an example to introduce the
parameter items as shown in Figure 17 to Figure 19. (Parameter items are
different due to different control modes.)
- “1.Setp” is the serial number of 8 steps, there are total max. 8 colors can be programmed for the periodical action, selectable range is 1-8.
- “2.Stay Time” is stay time of current selected programmed color.
- “3.Fade Time”is the fade time from current programmed color to next color.
- “4.Brightness” is the brightness percentage of current programmed color, modification range is 0-100.
- “5.Color” is the RGB values of the current programmed color, modification range is 0-255.
- “6.CCT” is the CCT value of current programmed color, modification range please refer to system parameter setting 3.3.3 CCT Range.
- “7.Enable” is the function to enable or disable current programmed color, “YES” means enable, “NO” means disable.
- “8. All Enable” is to enable or disable all programmed colors of the cycle periodical action, “YES” means enable, “NO” means disable.
- “9.Single View” is to preview current programmed color.
- “10.Multiple View” is to enable or disable to preview all programmed colors in the cycle periodical action, “YES” means enable, “NO” means disable
Note: T he actual duration of StayTime and FadeTime shall be associated
with 3.3.4 Cycle Time Scale
setting value.
Cycle Schedule Parameter Value Modification
Short press Plus key +/Minus key- to modify current selected parameter item value. Press and hold Plus key + /Minus key – to increase/decrease value rapidly.
Once any parameter item is selected, press and hold On/Off key , meanwhile after approximate 1 second, short press Plus key +/Minus key – to switch the serial number of the cycle schedules.
Cycle Schedule Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “OK” to indicate saving successfully.
Short press Back key to return to group configuration page.
Quick Start Function of the Cycle Schedule
Short press both Confirm key and any of the scene keys (1-8) simultaneously,
the master controller will start the cycle action with corresponding cycle
number. (Current version only includes Cycle Number=1)
Scene Setting:
Scene Setting Introduction:
Scene Setting is to set scene parameter value of each group, there are max. 16
groups, and each group has 8 scenes.
Enter into Scene Setting Page
Enter into Group configuration function page as shown in Figure 5 and Figure
6, short press Up key /Down key to select “5.Scene Setting”, short press
Confirm key to enter into Scene Setting page as shown in following Figure 20.
Figure 20
Scene Setting Parameter Items Selection
Short press Up key /Down key to switch and select a parameter item. The item
with underline is selected
Scene Setting Parameter Items Introduction:
Assume current group with control mode RGBCCT as an example to introduce the
parameter items as shown in Figure 20. (Parameter items are different due to
different control modes.)
- “1.Brightness” is the brightness percentage of the group, modification range is 0-100
- “2.Color” is the RGB values of the group, modification range is 0-255.
- “3.CCT” is the CCT value of the group, modification range please refer to system parameter setting 3.3.3 CCT Range.
Scene Setting Parameter Value Modification
Short press Plus key + /Minus key – to modify current selected parameter item
value. Press and hold Plus key + /Minus key – to increase/decrease value
rapidly.
Scene Setting Parameter Preview & Saving
Short press Confirm key , the lighting devices in the group will go to the
modified scene parameters, corresponding LED will indicate the loads’ on/off
status.
Press and hold Scene number keys (1-8) to save the modified parameters as a
corresponding scene of the group. The blank area of the display will show “OK”
to indicate saving successfully.
Short press a scene number key (1-8), the lighting device will go to
corresponding scene and show the scene parameter values on the display.
Short press Back key to return to group configuration page.
SYSTEM PARAMETER SETTING
Entering into & Quitting from System Parameter Setting Page
When the panel is unlocked, press and hold both Plus key + and Minus key – for
approximate 1 second to enter into system parameter setting page as shown in
following Figure 21 to Figure 23. There are 3 pages for the system parameter
setting.
Fig 21
Fig 22
Fig 23
On the system parameter setting page, press and hold both Plus key + and Minus key – for approximate 1 second to quit from the page. Or press and hold Back key to quit.
Group Total Setting
Group Total Setting Introduction
Group Total is the total valid group quantity that the DMX512 master system
has, modification range is 1-16.
Enter into Group Total Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “1.Group Total”, short press Confirm
key to enter into Group Total Setting page as shown in following Figure 24.
Fig 24
Group Total Parameter Value Modification
Short press Plus key + /Minus key – to modify total valid group quantity.
Press and hold Plus key + /Minus key – to increase/decrease quantity rapidly.
Group Total Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
CCT Range Setting:
CCT Range Setting Introduction:
CCT Range is the valid CCT value modification range. “WW” is the value of warm
white, valid modification range is 1000-4000. “CW” is the value of cool white,
valid modification range is 5000-10000.
Enter into CCT Range Setting Page
Enter into system parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “2.CCT Range”, short press Confirm key
to enter into CCT range Setting page as shown in following Figure 25.
Fig 25
CCT Range Parameter Items Selection
Short press Up key /Down key to switch and select a parameter item.
CCT Range Parameter Value Modification
Short press Plus key + /Minus key – to modify the selected parameter item.
Press and hold Plus key +/Minus key – to increase/decrease parameter value
rapidly.
CCT Range Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will
show “Save OK” to indicate saving successfully. Short press Back key to
return to system parameter setting
page
Cycle Time Scale Setting:
Cycle Time Scale Setting Introduction:
Cycle Time Scale is to set the time scale factor for all cycle schedules’ Stay
Time (Stay Time) and Fade Time (Fade Time), which can adjust the speed of LED
lighting color, color temperature fading.
Enter into Cycle Time Scale Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “3.Cycle Time Scale”, short press
Confirm key to enter into Cycle Time Scale Setting page as shown in following
Figure 26
Fig 26
Cycle Time Scale Parameter Items Introduction: The meaning of each parameter
item are described as shown in Figure 26
x0.1s:
The stay time of stay cycle schedules=Stay Time Parameter Value0.1S (Second)
The fade time of fade cycle schedules=Fade Time Parameter Value0.1S (Second
x0.2s
The stay time of stay cycle schedules=Stay Time Parameter Value0.2S (Second)
The fade time of fade cycle schedules=Fade Time Parameter Value0.2S (Second)
x0.5s:
The stay time of stay cycle schedules=Stay Time Parameter Value0.5S (Second)
The fade time of fade cycle schedules=Fade Time Parameter Value0.5S (Second)
x1.0s:
The stay time of stay cycle schedules=Stay Time Parameter Value1.0S (Second)
The fade time of fade cycle schedules=Fade Time Parameter Value1.0S (Second)
Cycle Time Scale Parameter Modification
Short press Up key /Down key or Plus key + /Minus key – to modify current
parameter value, the value with black font color and white background color is
current modified value.
Cycle Time Scale Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
Note: regarding the set parameter value of the time scale factor CycleTimeScale, please refer to the following table. (Single Scene Stay Time Average Min Data(ms), is just a similar reference time value.)
Item| Cycle Schedule
Group Enable Total| Fade Time=0
Group Total| Single Scene Stay Time
Average Min Data(ms)| Suggest Cycle Time
Scale Min Data
---|---|---|---|---
1| 1| 1| 140ms| x0.1
2| 2| 1| 200ms| x0.2
3| 3| 1| 300ms| x0.2
4| 4| 1| 400ms| x0.2
5| 5~6| 1| 500ms| x0.5
6| 7~8| 1| 600ms| x0.5
7| 9| 1| 900ms| x0.5
8| 10~16| 1| 1000ms| x1.0
Note: when the items are 3, 4, 6, 7, within the max value range of Cycle Schedule Group Enable Total, when\ Fade Time=0, Group Total >1, the value of Single Scene Stay Time Average Min Data(ms) will be a **little lower than reference values in above table.**
Beep Attribute Setting:
Beep Attribute Setting Introduction:
Beep attribute setting is to set the parameter of the beeper. When the beeper
is enabled, and the key is pressed, the beeper will beep once to indicate that
a key is pressed.
Enter into Beep Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “4.Beep”, short press Confirm key to
enter into Beep Setting page as shown in following Figure 27
Fig 27
Beep Parameter Items Introduction:
- Tone is to modify the tone of beeper, modification range is 1-100.
- Volume is to modify the sound volume of the beeper, modification range is 1-100.
- Enable is to enable or disable the beeper, “YES” means beeper function enabled, “NO” means the function
disabled
Beep Setting Parameter Items Selection
Short press Up key /Down key to select a parameter item, the parameter with
black font color and white background color is current selected item.
Beep Setting Parameter Modification
Short press Plus key + /Minus key – to modify the selected parameter item.
Press and hold Plus key +/Minus key – to increase/decrease parameter value
rapidly.
Beep Setting Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
Vibrator Setting:
Vibrator Setting Introduction:
Vibrator setting is to set the vibrator parameters. When the vibrator is
enabled, and a key is pressed, the vibrator will vibrate once to indicate a
key is pressed.
Enter into Vibrator Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “5.Vibrator”, short press Confirm key
to enter into Vibrator Setting page as shown in following Figure 28.
Fig 28
Vibrator Parameter Items Introduction:
- Vibrator Time is to modify the vibrating time of the vibrator, modification range is 0- 500.
- Enable is to enable or disable the vibrator, “YES” means vibrator function enabled, “NO” means the function disabled.
Vibrator Parameter Items Selection
Short press Up key /Down key to select a parameter item, the parameter with
underline is current selected item.
Vibrator Parameter Modification
Short press Plus key +/Minus key – to modify the selected parameter item.
Press and hold Plus key +/Minus key – to increase/decrease parameter value
rapidly.
Vibrator Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
Lock Panel Setting:
Lock Panel Setting Introduction:
Lock Panel is to set the parameter of locking touch panel of the controller.
When Lock Panel function is enabled, and the Lock Panel time elapsed, no any
operation on the keys, the touch panel will be locked. When locked, the logic
keys’ function will be invalid until the touch panel is unlocked. When Lock
panel function is disabled, the display will show screen protection with real
time after 30 seconds.
Enter into Lock Panel Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “6.Lock Panel”, short press Confirm key
to enter into Lock Panel Setting page as shown in following Figure 29.
Fig 29
Lock Panel Parameter Items Introduction:
- Lock time is to modify the time to lock the panel, modification range is 0-3600S (Seconds).
- Enable is to enable or disable Lock Panel function, “YES” means the function enabled, “NO” means the function disabled.
Lock Panel Parameter Items Selection
Short press Up key /Down key to select a parameter item, the parameter with
underline is current selected item
Lock Panel Parameter Modification
Short press Plus key + /Minus key -to modify the selected parameter item.
Press and hold Plus key +
/Minus key – to increase/decrease parameter value rapidly.
Lock Panel Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
OFF Display Setting
OFF Display Setting Introduction:
OFF Display is to set the parameter of the display going OFF. When OFF Display
function is enabled, and OFF display time elapsed, no any operation on the
keys, the display will go off. When Lock Panel function isenabled, OFF Display
time is counted after the panel locked, when Lock Panel function is disabled,
the display will show screen protection with real time after 30 seconds, then
OFF Display time will be counted.
Enter into OFF Display Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “7.OFF Display”, short press Confirm
key to enter into OFF Display Setting page as shown in following Figure 30
OFF Display Parameter Items Introduction:
- OFF Time is to modify the time that the display goes off, modification range is 0- 3600S (Seconds)
- Enable is to enable or disable the OFF Display function, “YES” means OFF Display function enabled, “NO” means the function disabled.
OFF Display Setting Parameter Selection
Short press Up key /Down key to select a parameter item, the parameter with
underline is current selected item
OFF Display Setting Parameter Modification
Short press Plus key +/Minus key – to modify the selected parameter item.
Press and hold Plus key +/Minus key – to increase/decrease parameter value
rapidly
OFF Display Setting Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
System Time Setting
System Time Setting Introduction
System Time is to set the parameter of system real time.
Enter into System Time Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “8.System Time”, short press Confirm
key to enter into System Time Setting page as shown in following Figure 31 to
Figure 33.
Fig 31
Fig 32
Fig 33
System Time Setting Parameter Items Introduction:
- System Time 1 line of the menus is current real time.
- The 01-07 items of the scroll down menus are the modified real time parameter.
System Time Parameter Items Selection
Short press Up key /Down key to select a parameter item, the parameter with
underline is current selected item.
System Time Parameter Modification
Short press Plus key + /Minus key – to modify the selected parameter item.
Press and hold Plus key + /Minus key – to increase/decrease parameter value
rapidly
System Time Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
Backlit Setting
Backlit Setting Introduction
Backlit is to set the parameter of the LED backlit brightness of the touch
panel, modification range is 0%-100%.
Enter into Backlit Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short press Up key /Down key to select “9.Backlit”, short press Confirm key to
enter into Backlit Setting page as shown in following Figure 34.
Fig 34
Backlit Parameter Modification
Short press Plus key /Minus key to modify the LED brightness. Press and hold
Plus key /Minus key to increase/decrease brightness value rapidly.
Backlit Parameter Saving
Short press Confirm key to confirm and save current modified parameter. The
blank area of the display will show “Save OK” to indicate saving successfully.
Short press Back key to return to system parameter setting page.
Factory Reset Setting
Factory Reset Setting Introduction
Factory rest is to restore the master controller setting to factory defaults.
Once factory reset, the controller’s all parameters will be restored to the
factory default values. It shall take a long time to reset, please be patient
to wait
Enter into Factory Reset Setting Page
Enter into System parameter setting page as shown in Figure 21 to Figure 23,
short
press Up key /Down key to select “10.Factory Reset”, short press Confirm key
to enter into Factory Reset Setting page as shown in following Figure 35
Factory Reset Parameter Items Introduction:
Enable is to enable or disable the Factory Reset function, “YES” means the
function enabled, “NO” means the function disabled.
Factory Reset Parameter Modification
Short press Plus key + /Minus key – to modify the status of “Enable”. “YES”
means Factory reset function is
enabled, “No” means the function is disabled.
Factory Reset Parameter Saving
Short press Confirm key to confirm and save the modified “Enable” status. The
“Status” on the display will show real time factory reset status as shown in
Figure 36 & Figure 37, The next line under “Status” shows the time needed for
factory reset. Short F press Back key to return to system parameter setting
page.
Fig 36
Fig 37
INSTALLATION
Master & PC Connection (If DMX PC software needs to be used)
Note:
- please use an USB-A male to Micro USB male data cable to connect the master and the computer.
- Please refer to the user manual of DMX Master PC software for detailed operations.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>