The unit must be installed by a qualified electrician in accordance with all national and local electrical and construction codes and regulations.

STEP 1 MOUNTING TO LOWER CEILING

Use fasteners that are appropriate for use with your mounting surface.

Fasten the Ceiling Plate M6i to the lower ceiling with suitable fastener.

Screw the Spherical Cap (with the Hanging Wire) to the CeilingPlate. Use of thread glue LOXEAL 5503 is recommended.

Anlois HP111 Ambiane Pendant Remote - Mounting 2

Drill the hole Ø8mm in the lower ceiling for the LED unit supply cable. If you wish to have the LED unit supply cable parallel with the hanging wire, the distance between the hanging wire and the LED unit supply cable should be 60mm.

STEP 2 CONTROL UNIT INSTALLATION

Use fasteners that are appropriate for use with your mounting surface.

Anlois HP111 Ambiane Pendant Remote - Figure 1Fasten the control unit on the ceiling by means of two holes in the control units housing.

STEP 3 LED UNIT SUPPLY CABLE CONNECTION

  1. Shorten power/data cable of LED unit to required length.
  2. Strip these lengths of LED unit‘s cable for wiring connection.Anlois HP111 Ambiane Pendant Remote - Figure 2LED Unit Connection
    TERMINAL BLOCK| +| A| B| –
    ---|---|---|---|---
    Colour of Wire| Red| White| Blue| Black

Anlois HP111 Ambiane Pendant Remote - Figure 3Pull the LED unit‘s cable through prepared hole in the ceiling and secure it above ceiling. Install a terminal block on the cable and connect it to the control unit.

STEP 4 PRIMARY POWER CONNECTION
Anlois HP111 Ambiane Pendant Remote - Figure 4 Install terminal block to power cable (from Ambiane Power Rack or Ambiane Power HP) and connect it to Primary power socket of the control unit.

STEP 5 SECONDARY POWER CONNECTION 48V (PSU SCOPE OF OTHERS)

Anlois HP111 Ambiane Pendant Remote - Figure 5 Install terminal block on Secondary power cable and connect it to Secondary power socket of the control unit.

STEP 6 DATA CABLES CONNECTION (DMX OR DALI)

Anlois HP111 Ambiane Pendant Remote - Figure 6 Install terminal blocks on DMX or DALI cables and connect them to the control unit.

DMX CONNECTION

0V| D-| D-
Data Ground| Data –| Data +

Set the DIP switches to positions according to your operation mode. The fixture can be controlled by DMX or DALI (switch 11 in OFF position).

STEP 7 ADJUSTING THE HANGING WIRE LENGTH

  1. Press down the pin on the wires connector for length adjustment.Anlois HP111 Ambiane Pendant Remote - Figure 7
  2. Press down pins on the hanging wires anchors for length and downward orientation adjustment.

Anlois Logo ROBE lighting s. r. o.
Palackeho 416 / 757 01 Valasske Mezirici
Czech Republic
Tel.: +420 571 751 500
E-mail: info@anolis.eu
www.anolislighting.com
VERSION 1.0 / 04_2022

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals