Focusrite RedNet 4 Dante Audio Interface Instructions
- September 28, 2024
- Focusrite
Table of Contents
RedNet 4 Dante Audio Interface
“`html
Product Specifications:
-
Compatible with: RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre,
Red 8Pre, and Red 16Line -
MIDI Control Capability
Product Usage Instructions:
Prerequisites:
Before using MIDI control with the mentioned devices, ensure you
have MIDI controllers available.
Setup in RedNet Control:
-
MIDI Input Device: Select the MIDI input
device you want to receive MIDI messages from. -
MIDI Output Device: Choose the output device
to send MIDI messages to. -
MIDI Input Protocol: Set the input protocol
for receiving MIDI messages. -
MIDI Output Protocol: Set the output protocol
for sending MIDI messages. -
MIDI Channel Allocation: Assign a MIDI channel
to each unit for control.
Setup with Pro Tools:
-
Install RedNet Control on the same computer as Pro Tools.
-
Configure the following settings in RedNet Control:
- MIDI Input Device
- MIDI Output Device
- MIDI Input Protocol
- MIDI Output Protocol
- MIDI Channel Allocation for RedNet 4 / RedNet MP8R / RedNet
X2P
-
Set up Pro Tools for PRE control:
-
Check RedNet Control under Setup > MIDI > Input
Devices. -
In Setup > Peripherals, set Receive From and Send To as
RedNet Control in the Mic Preamps tab. -
In Setup > I/O, assign mic pres to corresponding input
channels.
CC Protocol:
There are two CC protocol options available: Avid PRE (CC) – 3dB
steps and 1dB Step (CC) – 1dB steps. Use the provided format for CC
messages to control various functions of the mentioned units.
Frequently Asked Questions (FAQ):
Q: How many units can be connected for MIDI control?
A: You can connect up to nine units for MIDI control.
Q: What should be running first for best operation with Pro
Tools?
A: It is recommended that RedNet 4 / RedNet MP8R / RedNet X2P
and RedNet Control are running before launching Pro Tools.
“`
MIDI Control for RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre, Red 8Pre and Red
16Line
FFFA001405-05 1
Prerequisites
· Supported Mac or Windows PC · RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre,
Red 8Pre or Red 16Line hardware device · Compatible MIDI controller (see MIDI
Controllers) · RedNet Control must be running to send and receive MIDI
messages
MIDI Controllers
RedNet Control supports two different MIDI message types: · Controller Change
(CC) · System Exclusive (SysEx) A compatible controller must be able to send
user-programmable CC or SysEx messages. Since one of the CC protocol options
available is that of the Avid PRE (formerly known as Digidesign PRE), the
devices can be controlled from Pro Tools.
Setup in RedNet Control
There are five settings to consider: · MIDI Input Device · MIDI Output Device
· MIDI Input Protocol · MIDI Output Protocol · MIDI Channel allocation In
RedNet Control, select RedNet Control 2 and choose the Preferences sub menu.
2
The following options are available:
MIDI Input Device
“RedNet Control” is a software MIDI device that can receive MIDI messages from
other software. All other MIDI input devices will be displayed here. The
available devices will vary depending on what MIDI devices you have installed.
Choose the input device you would like to receive MIDI messages from.
MIDI Output Device
“RedNet Control” is a software MIDI device that can send MIDI messages to
other software. All other MIDI output devices will be displayed here. The
available devices will vary depending on what MIDI devices you have installed.
Choose the out device you would like to send MIDI messages to.
MIDI Input Protocol
Choose the input protocol RedNet Control shall receive.
MIDI Output Protocol
Choose the input protocol RedNet Control shall send.
MIDI Channel Allocation
By clicking on the “spanner” menu of any RedNet 4, RedNet MP8R, RedNet X2P,
Red 4Pre, Red 8Pre or Red 16Line, a MIDI channel can be selected to which the
unit will respond.
Note: · The default is “Off” · 16 channels are available, allowing a maximum
of 16 independent device control paths · Two devices should not be set to the
same MIDI channel · MIDI channel selection is saved with the computer, not the
device. Therefore
when controlling the same unit from a different computer, the MIDI channel
allocation may no longer be the same
3
Setup with Pro Tools
RedNet Control must be installed on the same computer as Pro Tools.
The following settings must be set within RedNet Control:
Setting MIDI Input Device MIDI Output Device MIDI Input Protocol MIDI Output Protocol RedNet 4 / RedNet MP8R / RedNet X2P MIDI Channel Allocation
Selection RedNet Control RedNet Control Avid Pre (CC) Avid Pre (CC) 116
Now set up Pro Tools for PRE control:
1. Click Setup > MIDI > Input Devices… and ensure the box next to RedNet
Control is checked
2. Click Setup>Peripherals and click the Mic Preamps tab
4
Here you can connect up to nine units Choose Type = PRE “Receive From” and
“Send To” must be set to “RedNet Control” and the same channel number set in
RedNet Control.
3. Click Setup>I/O and click the Mic Preamps tab
Here, assign the mic pres to the corresponding input channels.
5
Setup with Pro Tools continued
4. Pro Tools will now control RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre,
Red 8Pre and Red 16Line devices. Note, if you do not see the PRE controls at
the top of the mixer window, click the “Mix Window View Selector” in the
bottom left corner and select Mic Preamps
For best operation, it is recommended that RedNet 4 / RedNet MP8R / RedNet X2P and RedNet Control are running before Pro Tools is launched.
CC Protocol
There are two CC protocol options available: Avid PRE (CC) – 3dB steps. See
Table A and B. 1dB Step (CC) – 1dB steps. See Table A and C.
CC messages take the format:
Ba cc vv
Where:
a is the zero-indexed MIDI channel number in hex
cc is the control number in hex
vv is the value in hex
For example: B4h 19h 0Fh will set the following:
RedNet 4 / RedNet MP8R / RedNet X2P unit on MIDI channel 5
Input gain of mic pre channel 2
6
to a value of 45dB
Table A Control numbers and values
CC Hex 00h
01h 02h 04h 05h 06h 09h
CC Decimal 0
1 2 4 5 6 9
RedNet Mic Pre RedNet Mic Pre Values (Hex)
Function
Channel
Input Source 1
00h=mic,
01h=line,
03h=inst
Input Imped- 1
00h=2.4K,
ance
01h=10K
Pad / Air
1
00h=off,
7Fh=on
+48V
1
00h=off,
7Fh=on
Phase
1
00h=off,
7Fh=on
High Pass
1
00h=off,
Filter
7Fh=on
Input Gain
1
See Table B
RedNet 4 RedNet RedNet Red
MP8R X2P 4Pre
Yes
Yes
Yes
Yes
Air
Air
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Red 8Pre Yes
Air Yes Yes Yes Yes
Red 16Line Yes
Air Yes Yes Yes Yes
10h
16
11h
17
12h
18
14h
20
15h
21
16h
22
19h
25
20h
32
21h
33
22h
34
24h
36
25h
37
26h
38
29h
41
30h
48
31h
49
32h
50
34h
52
35h
53
36h
54
39h
57
7
Input Source 2
Input Imped- 2
ance
Pad / Air
2
+48V
2
Phase
2
High Pass
2
Filter
Input Gain
2
Input Source 3
Input Imped- 3
ance
Pad / Air
3
+48V
3
Phase
3
High Pass
3
Filter
Input Gain
3
Input Source 4
Input Imped- 4
ance
Pad / Air
4
+48V
4
Phase
4
High Pass
4
Filter
Input Gain
4
00h=mic,
Yes
01h=line,
03h=inst
00h=2.4K,
01h=10K
00h=off,
7Fh=on
00h=off,
Yes
7Fh=on
00h=off,
7Fh=on
00h=off,
Yes
7Fh=on
See Table B Yes
00h=mic,
Yes
01h=line,
03h=inst
00h=2.4K,
01h=10K
00h=off,
7Fh=on
00h=off,
Yes
7Fh=on
00h=off,
7Fh=on
00h=off,
Yes
7Fh=on
See Table B Yes
00h=mic,
Yes
01h=line,
03h=inst
00h=2.4K,
01h=10K
00h=off,
7Fh=on
00h=off,
Yes
7Fh=on
00h=off,
7Fh=on
00h=off,
Yes
7Fh=on
See Table B Yes
Yes
Yes
Yes
Yes
Yes
Air
Air
Air
Air
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Air
Air
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Air
Air
Yes
Yes
Yes
Yes
Yes Yes
Yes
Yes Yes
Yes
Yes Yes
Table A Control numbers and values continued
CC Hex CC
Decimal
40h
64
41h
65
42h
66
44h
68
45h
69
46h
70
49h
73
RedNet Mic Pre RedNet Mic Pre Values (Hex)
Function
Channel
Input Source 5
00h=mic,
01h=line,
03h=inst
Input Imped- 5
00h=2.4K,
ance
01h=10K
Pad / Air
5
00h=off,
7Fh=on
+48V
5
00h=off,
7Fh=on
Phase
5
00h=off,
7Fh=on
High Pass
5
00h=off,
Filter
7Fh=on
Input Gain
5
See Table B
RedNet 4 RedNet RedNet Red
MP8R X2P
4Pre
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
50h
80
51h
81
52h
82
54h
84
55h
85
56h
86
59h
89
Input Source 6
Input Imped- 6
ance
Pad / Air
6
+48V
6
Phase
6
High Pass
6
Filter
Input Gain
6
00h=mic,
Yes
01h=line,
03h=inst
00h=2.4K,
Yes
01h=10K
00h=off,
Yes
7Fh=on
00h=off,
Yes
Yes
7Fh=on
00h=off,
Yes
7Fh=on
00h=off,
Yes
Yes
7Fh=on
See Table B Yes
Yes
60h
96
61h
97
62h
98
64h
100
65h
101
66h
102
69h
105
Input Source 7
Input Imped- 7
ance
Pad / Air
7
+48V
7
Phase
7
High Pass
7
Filter
Input Gain
7
00h=mic,
Yes
01h=line,
03h=inst
00h=2.4K,
Yes
01h=10K
00h=off,
Yes
7Fh=on
00h=off,
Yes
Yes
7Fh=on
00h=off,
Yes
7Fh=on
00h=off,
Yes
Yes
7Fh=on
See Table B Yes
Yes
70h
112
71h
113
72h
114
74h
116
75h
117
76h
118
79h
121
Input Source 8
Input Imped- 8
ance
Pad / Air
8
+48V
8
Phase
8
High Pass
8
Filter
Input Gain
8
00h=mic,
Yes
01h=line,
03h=inst
00h=2.4K,
Yes
01h=10K
00h=off,
Yes
7Fh=on
00h=off,
Yes
Yes
7Fh=on
00h=off,
Yes
7Fh=on
00h=off,
Yes
Yes
7Fh=on
See Table B Yes
Yes
8
Red 8Pre Yes
Air Yes Yes Yes Yes Yes
Air Yes Yes Yes Yes Yes
Air Yes Yes Yes Yes Yes
Air Yes Yes Yes Yes
Red 16Line
Setup with Pro Tools continued
Table B Avid PRE (CC) Gain Values
Hex Decimal Pro Tools RedNet 4 RedNet 4 RedNet RedNet Red Red Red
dB
dB (Mic) dB (Line MP8R X2P dB 4Pre 8Pre 16Line
& Inst) dB
dB dB dB
00h 0
0
0
0
10
0
0
0
0
01h 1
3
8
3
10
3
8
8
8
02h 2
6
8
6
10
6
8
8
8
03h 3
9
9
9
10
9
9
9
9
04h 4
12
12
12
12
12
12 12
12
05h 5
15
15
15
15
15
15 15
15
06h 6
18
18
18
18
18
18 18
18
07h 7
21
21
21
21
21
21 21
21
08h 8
24
24
24
24
24
24 24
24
09h 9
27
27
27
27
27
27 27
27
0Ah 10
30
30
30
30
30
30 30
30
0Bh 11
33
33
33
33
33
33 33
33
0Ch 12
36
36
36
36
36
36 36
36
0Dh 13
39
39
39
39
39
39 39
39
0Eh 14
42
42
42
42
42
42 42
42
0Fh 15
45
45
45
45
45
45 45
45
10h 16
48
48
48
48
48
48 48
48
11h 17
51
51
51
51
51
51 51
51
12h 18
54
54
54
54
54
54 54
54
13h 19
57
57
54
57
57
57 57
57
14h 20
60
60
54
60
60
60 60
60
15h 21
63
63
54
63
63
63 63
63
16h 22
66
63
54
65
66
63 63
63
17h 23
69
63
54
65
68
63 63
63
When RedNet Control receives a MIDI message from Pro Tools, which is not supported by a device, the same message will be returned with the value set to “Off”
9
Table C 1dB Step (CC) Gain Values
Hex Decimal RedNet 4 RedNet 4 RedNet RedNet dB (Mic) dB (Line MP8R dB X2P dB & Inst)
Red
Red
Red
4Pre dB 8Pre dB 16Line
dB
00h 0
0
0
01h 1
1
1
02h 2
2
2
03h 3
3
3
04h 4
4
4
05h 5
5
5
06h 6
6
6
07h 7
7
7
08h 8
8
8
09h 9
9
9
0Ah 10
10
10
0Bh 11
11
11
0Ch 12
12
12
0Dh 13
13
13
0Eh 14
14
14
0Fh 15
15
15
10h 16
16
16
11h 17
17
17
12h 18
18
18
13h 19
19
19
14h 20
20
20
15h 21
21
21
16h 22
22
22
17h 23
23
23
18h 24
24
24
19h 25
25
25
1Ah 26
26
26
1Bh 27
27
27
1Ch 28
28
28
1Dh 29
29
29
1Eh 30
30
30
1Fh 31
31
31
20h 32
32
32
21h 33
33
33
22h 34
34
34
10
10
0
11
1
12
2
13
3
14
4
15
5
16
6
17
7
18
8
19
9
20
10
21
11
22
12
23
13
24
14
25
15
26
16
27
17
28
18
29
19
30
20
31
21
32
22
33
23
34
24
35
25
36
26
37
27
38
28
39
29
40
30
41
31
42
32
43
33
44
34
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10
10
10
11
11
11
12
12
12
13
13
13
14
14
14
15
15
15
16
16
16
17
17
17
18
18
18
19
19
19
20
20
20
21
21
21
22
22
22
23
23
23
24
24
24
25
25
25
26
26
26
27
27
27
28
28
28
29
29
29
30
30
30
31
31
31
32
32
32
33
33
33
34
34
34
Table C 1dB Step (CC) Gain Values
Hex Decimal RedNet 4 RedNet 4 RedNet RedNet X2P Red Red
Red
dB (Mic) dB (Line MP8R dB
4Pre dB 8Pre dB 16Line
& Inst) dB
dB
23h 35
35
35
24h 36
36
36
25h 37
37
37
26h 38
38
38
27h 39
39
39
28h 40
40
40
29h 41
41
41
2Ah 42
42
42
2Bh 43
43
43
2Ch 44
44
44
2Dh 45
45
45
2Eh 46
46
46
2Fh 47
47
47
30h 48
48
48
31h 49
49
49
32h 50
50
50
33h 51
51
51
34h 52
52
52
35h 53
53
53
36h 54
54
54
37h 55
55
54
38h 56
56
54
39h 57
57
54
3Ah 58
58
54
3Bh 59
59
54
3Ch 60
60
54
3Dh 61
61
54
3Eh 62
62
54
3Fh 63
63
54
40h 64
63
54
41h 65
63
54
42h 66
63
54
43h 67
63
54
44h 68
63
54
45
35
46
36
47
37
48
38
49
39
50
40
51
41
52
42
53
43
54
44
55
45
56
46
57
47
58
48
59
49
60
50
61
51
62
52
63
53
64
54
65
55
65
56
65
57
65
58
65
59
65
60
65
61
65
62
65
63
65
64
65
65
65
66
65
67
65
68
35
35
35
36
36
36
37
37
37
38
38
38
39
39
39
40
40
40
41
41
41
42
42
42
43
43
43
44
44
44
45
45
45
46
46
46
47
47
47
48
48
48
49
49
49
50
50
50
51
51
51
52
52
52
53
53
53
54
54
54
55
55
55
56
56
56
57
57
57
58
58
58
59
59
59
60
60
60
61
61
61
62
62
62
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
63
11
SysEx Protocol
Many devices can send and receive programmable SysEx messages. Please
configure your controller according to the manufacturer’s instructions using
the following protocol.
The following tables show the format of each control message.
Table D SysEx message format
Func.
Byte value (Hex)
Start SysEx
Manufacturer ID (Focusrite / Novation)
S/W RedNet Control
Version
F0h 00h 20h 29h 7Eh
02h
00h
Device Type
02h / 04h / 08h / 0Eh / 0Fh / 10h
Device Index
Mic Pre Channel
Parameter Parameter value
00h 0Fh (corresponds
to MIDI channel 1 16 assigned
to unit in RedNet Control
00h 07h for
channels 18
7Fh for unit-wide parameters
End SysEx
F7h
Byte
240
0 32 41 126
2
value
(Dec)
0
2 / 4 / 8
0 15
0 7 for
/ 14 / 15 (corresponds channels
/ 16
to MIDI
18
channel
1 16
127 for
assigned to
unit-wide
unit in
parameters
RedNet
Control
Notes
This will form the beginning of all messages
See Table E and F
Notes:
· The Manufacturer ID used (00h 20h 29h) is that of Novation, the sister brand
to Focusrite
247
This will end
each message
· The version field may change in future RedNet Control releases. Compatibility between different versions is not guaranteed
· 02h / 2 is the device type needed to use a RedNet X2P · 04h / 4 is the
device type needed to use a RedNet 4 · 08h / 8 is the device type needed to
use a RedNet MP8R · 0Eh / 14 is the device type needed to use a Red 4Pre · 0Fh
/ 15 is the device type needed to use a Red 8Pre · 10h / 16 is the device type
needed to use a Red 16Line
12
SysEx Protocol continued
Table E SysEx channel parameters and parameter values
Parameter Gain
Parameter Byte (hex)
00h
Input Source
01h
Phantom Power 02h
High Pass Filter 03h
Input Impedance 05h
Pad
07h
Air
08h
Phase
09h
Gain Compensation 0Eh
Parameter Value (hex)
RedNet X2P: 00h-44h, RedNet 4: 00h-3Fh, RedNet MP8R: 0Ah42h, Red 4Pre: 00h-
3Fh, Red 8Pre: 00h-3Fh, Red 16Line: 00h-3Fh,
00h = mic, 01h = line, 02h = inst
Parameter Value (dec)
RedNet X2P: 0-68dB, RedNet 4: 0-63dB, RedNet MP8R: 1065dB Red 4Pre: 0-63dB,
Red 8Pre: 0-63dB, Red 16Line: 0-63dB,
0 = mic, 1 = line, 2 = inst
00h = Off, any other value = On
0 = Off, any other value = On
00h = Off, any other value = On
0 = Off, any other value = On
00h = 2.4K, any other 0 = 2.4K, any other
value = 10K
value = 10K
00h = Off, any other value = On
0 = Off, any other value = On
00h = Off, any other value = On
0 = Off, any other value = On
00h = Off, any other value = On
0 = Off, any other value = On
00h = Off, any other value = On
0 = Off, any other value = On
13
Table F SysEx unit-wide parameters
Parameter Restore Defaults Identify Unit Clear Overs Gain Compensation Headroom Device Lock
Parameter Byte (hex) 00h 01h 02h 04h
05h
Parameter Value Any Any Any 00h = 0dB, 03h = 3dB, 06h = 6dB 00h = unlock, 01h = lock
For example, to send a message of: Set gain To 45 dB On channel 8 Of RedNet 4
assigned MIDI channel 2
The following message would be sent: F0h 00h 20h 29h 7Eh 02h 00h 04h 01h 07h
00h 2Dh F7h
Or to Identify RedNet MP8R assigned MIDI channel 6, the following message
would be sent: F0h 00h 20h 29h 7Eh 02h 00h 08h 05h 7Fh 00h 01h F7h
14
Troubleshooting
For a list of FAQs and general troubleshooting tips, our Answerbase is a
valuable resource. This can be found here: www.focusrite.com/answerbase If any
problem cannot be resolved, or if you have a query, please contact our
Customer Support team using the contact details found here. Focusrite Customer
Support: Email: focusriteprosupport@focusrite.com Phone (UK): +44 (0)1494 836
384 Phone (USA): +1 (310) 450 8494
15
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>