Focusrite RedNet 4 Dante Audio Interface Instructions

September 28, 2024
Focusrite

RedNet 4 Dante Audio Interface

“`html

Product Specifications:

  • Compatible with: RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre,
    Red 8Pre, and Red 16Line

  • MIDI Control Capability

Product Usage Instructions:

Prerequisites:

Before using MIDI control with the mentioned devices, ensure you
have MIDI controllers available.

Setup in RedNet Control:

  1. MIDI Input Device: Select the MIDI input
    device you want to receive MIDI messages from.

  2. MIDI Output Device: Choose the output device
    to send MIDI messages to.

  3. MIDI Input Protocol: Set the input protocol
    for receiving MIDI messages.

  4. MIDI Output Protocol: Set the output protocol
    for sending MIDI messages.

  5. MIDI Channel Allocation: Assign a MIDI channel
    to each unit for control.

Setup with Pro Tools:

  1. Install RedNet Control on the same computer as Pro Tools.

  2. Configure the following settings in RedNet Control:

    • MIDI Input Device
    • MIDI Output Device
    • MIDI Input Protocol
    • MIDI Output Protocol
    • MIDI Channel Allocation for RedNet 4 / RedNet MP8R / RedNet
      X2P
  3. Set up Pro Tools for PRE control:

  4. Check RedNet Control under Setup > MIDI > Input
    Devices.

  5. In Setup > Peripherals, set Receive From and Send To as
    RedNet Control in the Mic Preamps tab.

  6. In Setup > I/O, assign mic pres to corresponding input
    channels.

CC Protocol:

There are two CC protocol options available: Avid PRE (CC) – 3dB
steps and 1dB Step (CC) – 1dB steps. Use the provided format for CC
messages to control various functions of the mentioned units.

Frequently Asked Questions (FAQ):

Q: How many units can be connected for MIDI control?

A: You can connect up to nine units for MIDI control.

Q: What should be running first for best operation with Pro

Tools?

A: It is recommended that RedNet 4 / RedNet MP8R / RedNet X2P
and RedNet Control are running before launching Pro Tools.

“`

MIDI Control for RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre, Red 8Pre and Red 16Line
FFFA001405-05 1

Prerequisites
· Supported Mac or Windows PC · RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre, Red 8Pre or Red 16Line hardware device · Compatible MIDI controller (see MIDI Controllers) · RedNet Control must be running to send and receive MIDI messages
MIDI Controllers
RedNet Control supports two different MIDI message types: · Controller Change (CC) · System Exclusive (SysEx) A compatible controller must be able to send user-programmable CC or SysEx messages. Since one of the CC protocol options available is that of the Avid PRE (formerly known as Digidesign PRE), the devices can be controlled from Pro Tools.
Setup in RedNet Control
There are five settings to consider: · MIDI Input Device · MIDI Output Device · MIDI Input Protocol · MIDI Output Protocol · MIDI Channel allocation In RedNet Control, select RedNet Control 2 and choose the Preferences sub menu.
2

The following options are available:
MIDI Input Device
“RedNet Control” is a software MIDI device that can receive MIDI messages from other software. All other MIDI input devices will be displayed here. The available devices will vary depending on what MIDI devices you have installed. Choose the input device you would like to receive MIDI messages from.
MIDI Output Device
“RedNet Control” is a software MIDI device that can send MIDI messages to other software. All other MIDI output devices will be displayed here. The available devices will vary depending on what MIDI devices you have installed. Choose the out device you would like to send MIDI messages to.
MIDI Input Protocol
Choose the input protocol RedNet Control shall receive.
MIDI Output Protocol
Choose the input protocol RedNet Control shall send.
MIDI Channel Allocation
By clicking on the “spanner” menu of any RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre, Red 8Pre or Red 16Line, a MIDI channel can be selected to which the unit will respond.
Note: · The default is “Off” · 16 channels are available, allowing a maximum of 16 independent device control paths · Two devices should not be set to the same MIDI channel · MIDI channel selection is saved with the computer, not the device. Therefore
when controlling the same unit from a different computer, the MIDI channel allocation may no longer be the same
3

Setup with Pro Tools

RedNet Control must be installed on the same computer as Pro Tools.

The following settings must be set within RedNet Control:

Setting MIDI Input Device MIDI Output Device MIDI Input Protocol MIDI Output Protocol RedNet 4 / RedNet MP8R / RedNet X2P MIDI Channel Allocation

Selection RedNet Control RedNet Control Avid Pre (CC) Avid Pre (CC) 1­16

Now set up Pro Tools for PRE control:
1. Click Setup > MIDI > Input Devices… and ensure the box next to RedNet Control is checked

2. Click Setup>Peripherals and click the Mic Preamps tab
4

Here you can connect up to nine units Choose Type = PRE “Receive From” and “Send To” must be set to “RedNet Control” and the same channel number set in RedNet Control.
3. Click Setup>I/O and click the Mic Preamps tab
Here, assign the mic pres to the corresponding input channels.
5

Setup with Pro Tools continued
4. Pro Tools will now control RedNet 4, RedNet MP8R, RedNet X2P, Red 4Pre, Red 8Pre and Red 16Line devices. Note, if you do not see the PRE controls at the top of the mixer window, click the “Mix Window View Selector” in the bottom left corner and select Mic Preamps

For best operation, it is recommended that RedNet 4 / RedNet MP8R / RedNet X2P and RedNet Control are running before Pro Tools is launched.

CC Protocol
There are two CC protocol options available: Avid PRE (CC) – 3dB steps. See Table A and B. 1dB Step (CC) – 1dB steps. See Table A and C.

CC messages take the format:

Ba cc vv

Where:

a is the zero-indexed MIDI channel number in hex

cc is the control number in hex

vv is the value in hex

For example: B4h 19h 0Fh will set the following:

RedNet 4 / RedNet MP8R / RedNet X2P unit on MIDI channel 5

Input gain of mic pre channel 2

6

to a value of 45dB

Table A ­ Control numbers and values

CC Hex 00h
01h 02h 04h 05h 06h 09h

CC Decimal 0
1 2 4 5 6 9

RedNet Mic Pre RedNet Mic Pre Values (Hex)

Function

Channel

Input Source 1

00h=mic,

01h=line,

03h=inst

Input Imped- 1

00h=2.4K,

ance

01h=10K

Pad / Air

1

00h=off,

7Fh=on

+48V

1

00h=off,

7Fh=on

Phase

1

00h=off,

7Fh=on

High Pass

1

00h=off,

Filter

7Fh=on

Input Gain

1

See Table B

RedNet 4 RedNet RedNet Red

MP8R X2P 4Pre

Yes

Yes

Yes

Yes

Air

Air

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Red 8Pre Yes
Air Yes Yes Yes Yes

Red 16Line Yes
Air Yes Yes Yes Yes

10h

16

11h

17

12h

18

14h

20

15h

21

16h

22

19h

25

20h

32

21h

33

22h

34

24h

36

25h

37

26h

38

29h

41

30h

48

31h

49

32h

50

34h

52

35h

53

36h

54

39h

57

7

Input Source 2

Input Imped- 2

ance

Pad / Air

2

+48V

2

Phase

2

High Pass

2

Filter

Input Gain

2

Input Source 3

Input Imped- 3

ance

Pad / Air

3

+48V

3

Phase

3

High Pass

3

Filter

Input Gain

3

Input Source 4

Input Imped- 4

ance

Pad / Air

4

+48V

4

Phase

4

High Pass

4

Filter

Input Gain

4

00h=mic,

Yes

01h=line,

03h=inst

00h=2.4K,

01h=10K

00h=off,

7Fh=on

00h=off,

Yes

7Fh=on

00h=off,

7Fh=on

00h=off,

Yes

7Fh=on

See Table B Yes

00h=mic,

Yes

01h=line,

03h=inst

00h=2.4K,

01h=10K

00h=off,

7Fh=on

00h=off,

Yes

7Fh=on

00h=off,

7Fh=on

00h=off,

Yes

7Fh=on

See Table B Yes

00h=mic,

Yes

01h=line,

03h=inst

00h=2.4K,

01h=10K

00h=off,

7Fh=on

00h=off,

Yes

7Fh=on

00h=off,

7Fh=on

00h=off,

Yes

7Fh=on

See Table B Yes

Yes

Yes

Yes

Yes

Yes

Air

Air

Air

Air

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Air

Air

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Air

Air

Yes

Yes

Yes

Yes

Yes Yes

Yes

Yes Yes

Yes

Yes Yes

Table A ­ Control numbers and values continued

CC Hex CC

Decimal

40h

64

41h

65

42h

66

44h

68

45h

69

46h

70

49h

73

RedNet Mic Pre RedNet Mic Pre Values (Hex)

Function

Channel

Input Source 5

00h=mic,

01h=line,

03h=inst

Input Imped- 5

00h=2.4K,

ance

01h=10K

Pad / Air

5

00h=off,

7Fh=on

+48V

5

00h=off,

7Fh=on

Phase

5

00h=off,

7Fh=on

High Pass

5

00h=off,

Filter

7Fh=on

Input Gain

5

See Table B

RedNet 4 RedNet RedNet Red

MP8R X2P

4Pre

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

50h

80

51h

81

52h

82

54h

84

55h

85

56h

86

59h

89

Input Source 6

Input Imped- 6

ance

Pad / Air

6

+48V

6

Phase

6

High Pass

6

Filter

Input Gain

6

00h=mic,

Yes

01h=line,

03h=inst

00h=2.4K,

Yes

01h=10K

00h=off,

Yes

7Fh=on

00h=off,

Yes

Yes

7Fh=on

00h=off,

Yes

7Fh=on

00h=off,

Yes

Yes

7Fh=on

See Table B Yes

Yes

60h

96

61h

97

62h

98

64h

100

65h

101

66h

102

69h

105

Input Source 7

Input Imped- 7

ance

Pad / Air

7

+48V

7

Phase

7

High Pass

7

Filter

Input Gain

7

00h=mic,

Yes

01h=line,

03h=inst

00h=2.4K,

Yes

01h=10K

00h=off,

Yes

7Fh=on

00h=off,

Yes

Yes

7Fh=on

00h=off,

Yes

7Fh=on

00h=off,

Yes

Yes

7Fh=on

See Table B Yes

Yes

70h

112

71h

113

72h

114

74h

116

75h

117

76h

118

79h

121

Input Source 8

Input Imped- 8

ance

Pad / Air

8

+48V

8

Phase

8

High Pass

8

Filter

Input Gain

8

00h=mic,

Yes

01h=line,

03h=inst

00h=2.4K,

Yes

01h=10K

00h=off,

Yes

7Fh=on

00h=off,

Yes

Yes

7Fh=on

00h=off,

Yes

7Fh=on

00h=off,

Yes

Yes

7Fh=on

See Table B Yes

Yes

8

Red 8Pre Yes
Air Yes Yes Yes Yes Yes
Air Yes Yes Yes Yes Yes
Air Yes Yes Yes Yes Yes
Air Yes Yes Yes Yes

Red 16Line

Setup with Pro Tools continued

Table B ­ Avid PRE (CC) Gain Values

Hex Decimal Pro Tools RedNet 4 RedNet 4 RedNet RedNet Red Red Red

dB

dB (Mic) dB (Line MP8R X2P dB 4Pre 8Pre 16Line

& Inst) dB

dB dB dB

00h 0

0

0

0

10

0

0

0

0

01h 1

3

8

3

10

3

8

8

8

02h 2

6

8

6

10

6

8

8

8

03h 3

9

9

9

10

9

9

9

9

04h 4

12

12

12

12

12

12 12

12

05h 5

15

15

15

15

15

15 15

15

06h 6

18

18

18

18

18

18 18

18

07h 7

21

21

21

21

21

21 21

21

08h 8

24

24

24

24

24

24 24

24

09h 9

27

27

27

27

27

27 27

27

0Ah 10

30

30

30

30

30

30 30

30

0Bh 11

33

33

33

33

33

33 33

33

0Ch 12

36

36

36

36

36

36 36

36

0Dh 13

39

39

39

39

39

39 39

39

0Eh 14

42

42

42

42

42

42 42

42

0Fh 15

45

45

45

45

45

45 45

45

10h 16

48

48

48

48

48

48 48

48

11h 17

51

51

51

51

51

51 51

51

12h 18

54

54

54

54

54

54 54

54

13h 19

57

57

54

57

57

57 57

57

14h 20

60

60

54

60

60

60 60

60

15h 21

63

63

54

63

63

63 63

63

16h 22

66

63

54

65

66

63 63

63

17h 23

69

63

54

65

68

63 63

63

When RedNet Control receives a MIDI message from Pro Tools, which is not supported by a device, the same message will be returned with the value set to “Off”

9

Table C ­ 1dB Step (CC) Gain Values

Hex Decimal RedNet 4 RedNet 4 RedNet RedNet dB (Mic) dB (Line MP8R dB X2P dB & Inst)

Red

Red

Red

4Pre dB 8Pre dB 16Line

dB

00h 0

0

0

01h 1

1

1

02h 2

2

2

03h 3

3

3

04h 4

4

4

05h 5

5

5

06h 6

6

6

07h 7

7

7

08h 8

8

8

09h 9

9

9

0Ah 10

10

10

0Bh 11

11

11

0Ch 12

12

12

0Dh 13

13

13

0Eh 14

14

14

0Fh 15

15

15

10h 16

16

16

11h 17

17

17

12h 18

18

18

13h 19

19

19

14h 20

20

20

15h 21

21

21

16h 22

22

22

17h 23

23

23

18h 24

24

24

19h 25

25

25

1Ah 26

26

26

1Bh 27

27

27

1Ch 28

28

28

1Dh 29

29

29

1Eh 30

30

30

1Fh 31

31

31

20h 32

32

32

21h 33

33

33

22h 34

34

34

10

10

0

11

1

12

2

13

3

14

4

15

5

16

6

17

7

18

8

19

9

20

10

21

11

22

12

23

13

24

14

25

15

26

16

27

17

28

18

29

19

30

20

31

21

32

22

33

23

34

24

35

25

36

26

37

27

38

28

39

29

40

30

41

31

42

32

43

33

44

34

0

0

0

1

1

1

2

2

2

3

3

3

4

4

4

5

5

5

6

6

6

7

7

7

8

8

8

9

9

9

10

10

10

11

11

11

12

12

12

13

13

13

14

14

14

15

15

15

16

16

16

17

17

17

18

18

18

19

19

19

20

20

20

21

21

21

22

22

22

23

23

23

24

24

24

25

25

25

26

26

26

27

27

27

28

28

28

29

29

29

30

30

30

31

31

31

32

32

32

33

33

33

34

34

34

Table C ­ 1dB Step (CC) Gain Values

Hex Decimal RedNet 4 RedNet 4 RedNet RedNet X2P Red Red

Red

dB (Mic) dB (Line MP8R dB

4Pre dB 8Pre dB 16Line

& Inst) dB

dB

23h 35

35

35

24h 36

36

36

25h 37

37

37

26h 38

38

38

27h 39

39

39

28h 40

40

40

29h 41

41

41

2Ah 42

42

42

2Bh 43

43

43

2Ch 44

44

44

2Dh 45

45

45

2Eh 46

46

46

2Fh 47

47

47

30h 48

48

48

31h 49

49

49

32h 50

50

50

33h 51

51

51

34h 52

52

52

35h 53

53

53

36h 54

54

54

37h 55

55

54

38h 56

56

54

39h 57

57

54

3Ah 58

58

54

3Bh 59

59

54

3Ch 60

60

54

3Dh 61

61

54

3Eh 62

62

54

3Fh 63

63

54

40h 64

63

54

41h 65

63

54

42h 66

63

54

43h 67

63

54

44h 68

63

54

45

35

46

36

47

37

48

38

49

39

50

40

51

41

52

42

53

43

54

44

55

45

56

46

57

47

58

48

59

49

60

50

61

51

62

52

63

53

64

54

65

55

65

56

65

57

65

58

65

59

65

60

65

61

65

62

65

63

65

64

65

65

65

66

65

67

65

68

35

35

35

36

36

36

37

37

37

38

38

38

39

39

39

40

40

40

41

41

41

42

42

42

43

43

43

44

44

44

45

45

45

46

46

46

47

47

47

48

48

48

49

49

49

50

50

50

51

51

51

52

52

52

53

53

53

54

54

54

55

55

55

56

56

56

57

57

57

58

58

58

59

59

59

60

60

60

61

61

61

62

62

62

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

63

11

SysEx Protocol

Many devices can send and receive programmable SysEx messages. Please configure your controller according to the manufacturer’s instructions using the following protocol.
The following tables show the format of each control message.

Table D ­ SysEx message format

Func.
Byte value (Hex)

Start SysEx

Manufacturer ID (Focusrite / Novation)

S/W RedNet Control

Version

F0h 00h 20h 29h 7Eh

02h

00h

Device Type
02h / 04h / 08h / 0Eh / 0Fh / 10h

Device Index

Mic Pre Channel

Parameter Parameter value

00h ­ 0Fh (corresponds
to MIDI channel 1 ­ 16 assigned
to unit in RedNet Control

00h ­ 07h for
channels 1­8
7Fh ­ for unit-wide parameters

End SysEx
F7h

Byte

240

0 32 41 126

2

value

(Dec)

0

2 / 4 / 8

0 ­ 15

0 ­ 7 for

/ 14 / 15 (corresponds channels

/ 16

to MIDI

1­8

channel

1 ­ 16

127 for

assigned to

unit-wide

unit in

parameters

RedNet

Control

Notes

This will form the beginning of all messages

See Table E and F

Notes:
· The Manufacturer ID used (00h 20h 29h) is that of Novation, the sister brand to Focusrite

247
This will end
each message

· The version field may change in future RedNet Control releases. Compatibility between different versions is not guaranteed

· 02h / 2 is the device type needed to use a RedNet X2P · 04h / 4 is the device type needed to use a RedNet 4 · 08h / 8 is the device type needed to use a RedNet MP8R · 0Eh / 14 is the device type needed to use a Red 4Pre · 0Fh / 15 is the device type needed to use a Red 8Pre · 10h / 16 is the device type needed to use a Red 16Line
12

SysEx Protocol continued

Table E ­ SysEx channel parameters and parameter values

Parameter Gain

Parameter Byte (hex)
00h

Input Source

01h

Phantom Power 02h

High Pass Filter 03h

Input Impedance 05h

Pad

07h

Air

08h

Phase

09h

Gain Compensation 0Eh

Parameter Value (hex)
RedNet X2P: 00h-44h, RedNet 4: 00h-3Fh, RedNet MP8R: 0Ah42h, Red 4Pre: 00h- 3Fh, Red 8Pre: 00h-3Fh, Red 16Line: 00h-3Fh,
00h = mic, 01h = line, 02h = inst

Parameter Value (dec)
RedNet X2P: 0-68dB, RedNet 4: 0-63dB, RedNet MP8R: 1065dB Red 4Pre: 0-63dB, Red 8Pre: 0-63dB, Red 16Line: 0-63dB,
0 = mic, 1 = line, 2 = inst

00h = Off, any other value = On

0 = Off, any other value = On

00h = Off, any other value = On

0 = Off, any other value = On

00h = 2.4K, any other 0 = 2.4K, any other

value = 10K

value = 10K

00h = Off, any other value = On

0 = Off, any other value = On

00h = Off, any other value = On

0 = Off, any other value = On

00h = Off, any other value = On

0 = Off, any other value = On

00h = Off, any other value = On

0 = Off, any other value = On

13

Table F ­ SysEx unit-wide parameters

Parameter Restore Defaults Identify Unit Clear Overs Gain Compensation Headroom Device Lock

Parameter Byte (hex) 00h 01h 02h 04h
05h

Parameter Value Any Any Any 00h = 0dB, 03h = 3dB, 06h = 6dB 00h = unlock, 01h = lock

For example, to send a message of: Set gain To 45 dB On channel 8 Of RedNet 4 assigned MIDI channel 2
The following message would be sent: F0h 00h 20h 29h 7Eh 02h 00h 04h 01h 07h 00h 2Dh F7h
Or to Identify RedNet MP8R assigned MIDI channel 6, the following message would be sent: F0h 00h 20h 29h 7Eh 02h 00h 08h 05h 7Fh 00h 01h F7h

14

Troubleshooting
For a list of FAQs and general troubleshooting tips, our Answerbase is a valuable resource. This can be found here: www.focusrite.com/answerbase If any problem cannot be resolved, or if you have a query, please contact our Customer Support team using the contact details found here. Focusrite Customer Support: Email: focusriteprosupport@focusrite.com Phone (UK): +44 (0)1494 836 384 Phone (USA): +1 (310) 450 8494
15

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Focusrite User Manuals

Related Manuals