PENTAIR 230V Booster Pressure Side Cleaner Pump
Product Specifications
- Product Name: Booster Pump Pressure-Side Cleaner Pump
- Model Number: Not specified
- Power Source: Electric
- Recommended Usage: Permanent swimming pools, hot tubs, spas
- Electrical Safety: Connect only to a GFCI-protected branch circuit
- Bonding Conductor Requirement: No. 8 AWG solid copper
Product Usage Instructions
Installation:
- Ensure the pump is installed by a qualified pool service professional.
- Connect the bonding conductor from the motor to all metal parts of the pool structure.
- Follow all safety instructions in the manual during installation.
Operation:
- Connect the pump to a GFCI-protected branch circuit.
- Do not allow children to use the product.
- Only use the pump with permanent swimming pools, hot tubs, or spas.
Maintenance:
- Regularly check for any damage to the pump or wiring.
- Keep safety labels in good condition and replace if missing or damaged.
- Refer to the owner’s manual for maintenance guidelines.
Frequently Asked Questions
Q: Can this pump be used with storable pools?
A: No, this pump is designed for use with permanent swimming pools and should not be used with storable pools.
Q: What type of electrical circuit should the pump be connected to?
A: The pump should only be connected to a branch circuit protected by a ground-fault circuit interrupter (GFCI) to prevent electrical shock.
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
IMPORTANT
A solid copper bonding conductor, not smaller than No. 8 AWG, should be
connected from the accessible wire connector on the motor to all metal parts
of the swimming pool, spa or hot tub structure and to all electrical
equipment, metal conduit and metal piping within 5 ft. (1.5 m) of the inside
walls of the swimming pool, spa or hot tub when the motor is installed within
5 ft. (1.5 m) of the inside walls of the swimming pool, spa or hot tub.
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT NOTICE
This guide provides installation and operation instructions for this pump.
Consult Pentair with any questions regarding this equipment.
Attention Installer: This guide contains important information about the
installation, operation and safe use of this product. This information should
be given to the owner and/or operator of this equipment after installation or
left on or near the pump.
Attention User: This manual contains important information that will help you
in operating and maintaining this product. Please retain it for future
reference.
READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
This is the safety alert symbol. When you see this symbol on your system or in this manual, look for one of the following signal words and be alert to the potential for personal injury.
-
DANGER
Warns about hazards that can cause death, serious personal injury, or major property damage if ignored. -
WARNING
Warns about hazards that may cause death, serious personal injury, or major property damage if ignored. -
CAUTION
Warns about hazards that may or can cause minor personal injury or property damage if ignored. -
NOTE
Indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on equipment. Keep safety labels in good condition; replace if missing or damaged.
When installing and using this electrical equipment, basic safety precautions should always be followed, include the following:
FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S MANUAL BEFORE USING THIS PUMP. THESE WARNINGS AND THE OWNER’S MANUAL MUST BE LEFT WITH THE POOL OWNER.
WARNING
Do not permit children to use this product.
WARNING
RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a
ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if
you cannot verify that the circuit is protected by a GFCI.
WARNING
This unit must be connected only to a supply circuit that is protected by a
ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the
installer and should be tested on a routine basis. To test the GFCI, push the
test button. The GFCI should interrupt power. Push the reset button. Power
should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button
being pushed, a ground current is flowing, indicating the possibility of an
electric shock. Do not use this pump. Disconnect the pump and have the problem
corrected by a qualified service representative before using.
CAUTION
This pump is for use with permanent swimming pools and may also be used with
hot tubs and spas if so marked. Do not use with storable pools. A permanently-
installed pool is constructed in or on the ground or in a building such that
it cannot be readily disassembled for storage. A storable pool is constructed
so that it is capable of being readily disassembled for storage and
reassembled to its original integrity.
General Warnings
- Never open the inside of the drive motor enclosure. There is a capacitor bank that holds a 230 VAC charge even when there is no power to the unit.
- The pump is not submersible.
- The pump is capable of high flow rates; use caution when installing and programming to limit pumps performance potential with old or questionable equipment.
- Code requirements for electrical connection differ from country to country, state to state, as well as local municipalities. Install equipment in accordance with the National Electrical Code and all applicable local codes and ordinances.
- Before servicing the pump, switch OFF power to the pump by disconnecting the main circuit to the pump.
- This appliance is not intended for use by persons (including children) of reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
DANGER
SUCTION ENTRAPMENT HAZARD: STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION
OUTLETS! THIS PUMP IS NOT EQUIPPED WITH SAFETY VACUUM RELEASE SYSTEM (SVRS)
PROTECTION AND DOES NOT PROTECT AGAINST BODY OR LIMB ENTRAPMENTS,
DISEMBOWELMENTS (WHEN A PERSON SITS ON A BROKEN OR UNCOVERED POOL DRAIN) OR
HAIR ENTANGLEMENTS.
THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE
MAIN DRAIN AT THE BOTTOM OF THE BODY OF WATER. THIS SUCTION IS SO STRONG THAT
IT CAN TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO
A DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.
THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS
ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR
ENTANGLEMENT, BODY ENTRAPMENT, EVISCERATION AND/OR DEATH.
The suction at a drain or outlet can cause:
- Limb Entrapment: When a limb is sucked or inserted into an opening resulting in a mechanical bind or swelling. This hazard is present when a drain cover is missing, broken, loose, cracked or not properly secured.
- Hair Entanglement: When the hair tangles or knots in the drain cover, trapping the swimmer underwater. This hazard is present when the flow rating of the cover is too small for the pump or pumps.
- Body Entrapment: When a portion of the body is held against the drain cover trapping the swimmer underwater. This hazard is present when the drain cover is missing, broken or the cover flow rating is not high enough for the pump or pumps.
- Evisceration/Disembowelment: When a person sits on an open pool (particularly a child wading pool) or spa outlet and suction is applied directly to the intestines, causing severe intestinal damage. This hazard is present when the drain cover is missing, loose, cracked, or not properly secured.
- Mechanical Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle is caught in an opening of an outlet or drain cover. This hazard is present when the drain cover is missing, broken, loose, cracked, or not properly secured.
- NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL AND LOCAL CODES, STANDARDS AND GUIDELINES.
WARNING
TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD:
- A properly installed and secured ANSI/ASME A112.19.8 approved anti-entrapment suction cover must be used for each drain.
- Each suction cover must be installed at least three (3’) feet apart, as measured from the nearest point to nearest point.
- Regularly inspect all covers for cracks, damage and advanced weathering.
- If a cover becomes loose, cracked, damaged, broken or is missing, replace with an appropriate certified cover.
- Replace drain covers as necessary. Drain covers deteriorate over time due to exposure to sunlight and weather.
- Avoid getting hair, limbs or body in close proximity to any suction cover, pool drain or outlet.
- Disable suction outlets or reconfigure into return inlets.
WARNING
The pump can produce high levels of suction within the suction side of the
plumbing system. These high levels of suction can pose a risk if a person
comes within the close proximity of the suction openings. A person can be
seriously injured by this high level of vacuum or may become trapped and
drown. It is absolutely critical that the suction plumbing be installed in
accordance with the latest national and local codes for swimming pools.
WARNING
A clearly labeled emergency shut-off switch for the pump must be in an easily
accessible, obvious place. Make sure users know where it is and how to use it
in case of emergency.
The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new
requirements for owners and operators of commercial swimming pools and spas.
Commercial pools or spas constructed on or after December 19, 2008, shall
utilize:
(A) A multiple main drain system without isolation capability with suction
outlet covers that meet ASME/ANSI A112.19.8a Suction Fittings for Use in
Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:
- A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 Manufactured Safety Vacuum Release systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems and/or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming pools, Spas and Hot Tubs or
- A properly designed and tested suction-limiting vent system or
- An automatic pump shut-off system.
Commercial pools and spas constructed prior to December 19, 2008, with a single submerged suction outlet shall use a suction outlet cover that meets ASME/ANSI A112.19.8a and either:
- (A) A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
- (B) A properly designed and tested suction-limiting vent system, or
- (C) An automatic pump shut-off system, or
- (D) Disabled submerged outlets, or
- (E) Suction outlets shall be reconfigured into return inlets.
CAUTION
For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches,
Timers and Automation Load Center) Install all electrical controls at
equipment pad, such as on/off switches, timers, and control systems, etc. to
allow the operation (startup, shut-down, or servicing) of any pump or filter
so the user does not place any portion of his/her body over or near the pump
strainer lid, filter lid or valve closures. This installation should allow the
user enough space to stand clear of the filter and pump during system start-
up, shut down or servicing of the system filter.
DANGER
HAZARDOUS PRESSURE: STAND CLEAR OF PUMP AND FILTER DURING START UP.
Circulation systems operate under high pressure. When any part of the
circulating system (i.e. locking ring, pump, filter, valves, etc.) is
serviced, air can enter the system and become pressurized. Pressurized air can
cause the pump housing cover, filter lid, and valves to violently separate
which can result in severe personal injury or death. Filter tank lid and
strainer cover must be properly secured to prevent violent separation. Stand
clear of all circulation system equipment when turning on or starting up pump.
Before servicing equipment, make note of the filter pressure. Be sure that all
controls are set to ensure the system cannot inadvertently start during
service. Turn off all power to the pump. IMPORTANT: Place filter manual air
relief valve in the open position and wait for all pressure in the system to
be relieved. Before starting the system, fully open the manual air relief
valve and place all system valves in the “open” position to allow water to
flow freely from the tank and back to the tank. Stand clear of all equipment
and start the pump. IMPORTANT: Do not close filter manual air relief valve
until all pressure has been discharged from the valve and a steady stream of
water appears. Observe filter pressure gauge and be sure it is not higher than
the pre-service condition.
General Installation Information
- All work must be performed by a qualified service professional, and must conform to all national, state, and local codes.
- Install to provide drainage of compartment for electrical components.
- These instructions contain information for a variety of pump models and therefore some instructions may not apply to a specific model. All models are intended for use in swimming pool applications. The pump will function correctly only if it is properly sized to the specific application and properly installed.
WARNING
Pumps improperly sized or installed or used in applications other than for
which the pump was intended can result in severe personal injury or death.
These risks may include but not be limited to electric shock, fire, flooding,
suction entrapment or severe injury or property damage caused by a structural
failure of the pump or other system component.
Pumps and replacement motors that are single speed and one (1) Total HP or greater cannot be sold, offered for sale, or installed in a residential pool for filtration use in California, Title 20 CCR sections 1601-1609.
CUSTOMER SERVICE / TECHNICAL SUPPORT
Hours: 9:00AM to 7:00PM EST (6:00AM – 4:00PM PST) Call:
800-831-7133
Visit: www.pentair.com
Fax: 800-284-4151
INSTALLATION
This booster pump is a 1.13 horsepower pump with a 1.0 service factor. The pump produces a minimum of 50 psi (3.4 bar) at 12 GPM (45.4 LPM).
Unit Location
Pump should be installed on a firm and level surface. Unless required by a
local code, it need not be bolted down. Installation should be as close as
possible to a filtered water return line and a convenient location for
servicing.
Note: Booster pump must always be connected to return line on discharge side of filter. Never connect suction side booster pump ahead of filter. See Figure 1: Typical Installation at the bottom of this page.
Typical Installation – Heater Consideration
Suction side of booster pump must be connected to the return line after the
heater. Except on solar installations, never connect suction side of booster
pump ahead of filter or heater.
Figure 1: Typical Installation
Note: Keep booster pump a minimum of 3 feet (0.9 meters) from heater. See Figure 2A: Installation with Heater.
Figure 2A: Installation with Heater
Installation with Solar Heater
With or without a gas heater for back-up, when installing any one of Pentair’s
automatic pool cleaners in a pool with solar heating, the in-line tee must be
installed on the return line between the filter and the solar heater. This
minimizes the possibilities of an air lock in the sweep pump each time the
solar panel is filled and assures an ample supply of water. (See Figure 2B:
Installation with Solar Heater.)
Figure 2B: Installation with Solar Heater
Installation with Spa Pools
Connect suction side of the booster pump before spa bypass valve, if your pool
is plumbed for a spa pool. See Figure 3: Installation with Pool/Spa Combo.
Pump Inlet Connection to Return Line
Use elbow and reduce bushing if needed on pre-plumbed installation. Use tee on
existing installation. Connect pump suction to the return line after filter
and heater as follows: preferably, underneath side (NEVER ON TOP) of the
horizontal return line.
Installation of Pump Hoses
-
Remove the adapter from hose kit bag (P/N 353020) and wrap thread seal tape around the 3/4-inch NPT threads of the adapter.
Atleast four wraps is recommended. -
Screw the adapter into the pump outlet. Torque to 60 in-lbs (6.8 Nm).
-
Cut the hose to an appropriate length.
6 feet (1.8 m) of hose has been provided for both the inlet and outlet. -
Place the adapter cap over the hose (Figure 4: Installation of Pump Hoses) and slide the hose onto the adapter until the hose is flush against the wall where the threads begin.
-
Heating of the hose or use of a lubricant may be useful if the hose is cold.
-
Screw the adapter cap onto the adapter and tighten to 60 in-lbs (6.8 Nm).
-
Repeat the process for both the inlet and outlet of pump. When routing the hose, make sure there are no tight bends or kinks in the hose.
Figure 4: Installation of Pump Hoses
Specifications
- Dimensions: 16.2” x 9.1” x 12.2” (see below)
- Motor: 1.13 THP, 60 Hz
- Power Supply: 120/240 VAC
Electrical Connections
WARNING
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This pump must be installed by a licensed or certified electrician or a
qualified service professional in accordance with the National Electrical Code
(NEC) and all other applicable national or local codes and ordinances.
Improper installation will create an electrical hazard which could result in
death or serious injury to users, installers, or others due to electrical
shock, and may also cause damage to property. Always disconnect power to the
pump at the circuit breaker before servicing the pump. Failure to do so could
result in death or serious injury to service people, users or others due to
electric shock. Read all servicing instructions before working on the pump.
Wiring
-
Be sure all electrical breakers, switches, and automatic controls are turned off before wiring motor.
STORED CHARGE – Wait at least sixty (60) seconds before servicing. -
Become familiar with the wiring diagram, volts, hertz, amps, and phase of your particular pump motor. All of this information is provided on the motor nameplate label found on the side of the motor.
-
Be sure that the supply voltage meets the requirements listed on the motor nameplate. If these requirements are not met, permanent motor damage may occur.
-
For wiring sizes and general guidelines for proper electrical installation, please follow the specifications defined in the National Electrical Code and all other applicable national or local codes.
-
3-Phase motors require external overload protection. An initial inspection is needed to ensure proper rotation of the pump.
Once installed, momentarily cycle the power on and then off. Note the rotation of the motor fan or shaft as it comes to a stop. If wired correctly, the motor shaft and/or fan will match the rotation arrow noted on the pump. -
Use a strain relief and be sure all electrical connections are clean and tight.
-
Cut the wires to the appropriate length so they do not overlap or touch when connected.
Grounding
- Permanently ground the motor using the green ground screw. Use the correct wire size and type specified by the National Electrical Code. Ensure the ground wire is connected to an electrical service ground.
- The pump should be permanently connected to either a circuit breaker, 2-pole timer, or 2-pole relay.
Note: If AC power is supplied by a GFCI circuit breaker, the pump should be wired on its own independent circuit unless the pump is operated in tandem with a Pentair salt chlorine generator.
MAINTENANCE
Bonding
- Bond the motor to the structure in accordance with the National Electrical Code and all other applicable national or local codes. Use a solid copper bonding conductor not smaller than 8 AWG. For Canadian installations, a 6 AWG or larger solid copper bonding conductor is required. Run a wire from the external bonding screw or lug to the bonding structure.
- Connect the wire from the accessible bonding lug on the motor to all metal parts of the swimming pool, spa, or hot tub structure and to all electrical equipment, metal conduit, and metal piping within 5 feet (1.5 m) of the inside walls of the swimming pool, spa, or hot tub. Run a wire from the external bonding screw or lug to the bonding structure.
WARNING
Before establishing or restoring power to the pump,be sure all electrical connections are tight and all electrical and wiring compartment covers are properly installed.
Note: When the pump is started and stopped by removing power with a relay or timer, a 2-pole device should be used to apply and remove power to both POWER LINE TERMINALS.
Pentair offers GFCI breakers which offer appropriate personal protection while meeting 2008 to current NEC Standards for Pool Pumps. See Pentair product catalog for details.
Time Clock
A separate time clock is recommended. To ensure proper sequence of filter pump
and booster pump, the time clocks must be reset if power is interrupted.
The automatic pool cleaner must be run for a length of time necessary to clean
the pool, but should never be allowed to run while filter system is off. This
will result in damage to the booster pump. Running the automatic pool cleaner
without the filter system in operation will void warranty. The automatic pool
cleaner should start operating one-half hour to forty-five minutes after the
filter pump starts, and stop one-half hour to forty-five minutes before the
filter pump stops.
Manual Switch
A manual switch is recommended. It should be located between the time clock
and the booster pump. The switch eliminates turning the pump off at the time
clock.
Pump Seal
The booster pump is fitted with a mechanical shaft seal which is water-
lubricated and water-cooled. If the pump is run without water, this seal will
be damaged. NEVER OPERATE UNLESS FILTER SYSTEM IS ON.
Servicing the Pump
This motor is a drip-proof motor, but can be damaged by rainfall, splash, or
flooding caused by water entering the motor.
Disassembly
- Turn off booster pump motor and close valves.
- Unscrew suction line in middle of volute.
- Loosen nuts and remove bolts between booster pump volute and seal bracket.
- Remove cap from the back end of motor. Use a crescent wrench or open-end wrench to hold shaft from spinning.
- Hold wrench and turn impeller counter-clockwise to remove.
Removing the Seal
- Stand motor on end. Using one screwdriver, slowly pry seal out of impeller. Remove seal bracket and dislodge seal from backside of seal bracket using hammer and screwdriver.
Reassembly
- After replacing the necessary parts, reassemble by reversing order of steps 1-5 above.
- Ceramic seal must be perfectly clean of any foreign objects or dirt. If seal is not clean, it will cause leakage. The ceramic seal must go in with the side containing grooves facing into the center of the rubber gasket, otherwise it will leak.
- Replace impeller and seals if warped or discolored. This condition is caused by overheating due to pump running dry. Smooth surface or ceramic seal should be parallel to and facing away from back side of impeller.
- Silicone backside of metal flange on spring seal, and push down until flush in center of seal bracket. Be careful not to get silicone on the spring seals’ contact surface.
If you have any questions, contact Pentair at: 1-800-831-7133
REPLACEMENT PARTS
Note: As of October 2023, pump motor is no longer offered as a replacement part.
Item | P/N | Description | Qty. |
---|---|---|---|
1 | LA125 | Nut, Motor | 8 |
2 | LA135 | Bolt, Motor | 2 |
3 | LA295 | Seal Bracket | 1 |
4 | LA415 | O-ring, Seal Bracket | 1 |
5 | 071734s | Shaft Seal | 1 |
6 | LA05L | Impeller | 1 |
7 | LA39534 | Volute | 1 |
8 | LA115 | Bolt, Volute | 8 |
9 | MA36s | Grommet | 2 |
10 | LA41 | Motor Stand | 1 |
11 | MA36 | Grommet | 4 |
12 | LA136 | Bolt, Motor Stand | 2 |
13 | LA385 | Drain Plug | 1 |
– | PA375 | O-ring, Drain Plug | 1 |
– | 353020 | Hose Kit | 1 |
1620 HAWKINS AVE., SANFORD, NC 27330 •
919-566-8000
10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 •
805-553-5000
All indicated Pentair trademarks and logos are property of Pentair. Third
party registered and unregistered trademarks and logos are the property of
their respective owners.
© 2023 Pentair. All rights reserved. WWW.PENTAIR.COM