Product Usage Instructions
Installation Instructions
The Device can control various types of loads in one electrical circuit. It can be retrofitted into standard electrical wall boxes, behind power sockets, light switches, or other places with limited space.
CAUTION! Before starting the mounting/installation of the Device, ensure that the breakers are turned off and there is no voltage on their terminals. Use a phase tester or multimeter to check for voltage. Connect the load circuit to the Device I and O terminals. For AC power supply, connect the Live wire to the Device L terminal and the Neutral wire to the N terminal as shown in Fig. 1. Connect a switch or push-button to the Device SW terminal and the Live wire.
Operational Instructions
If the SW is configured as a switch (default), each toggle of the switch
will change the output O state to the opposite state – on, off, on, etc. If
configured as a push-button in the Device settings, each press of the push-
button will change the output O state similarly.
Supported Load Types
- Resistive: Incandescent bulbs, heating devices
- Capacitive: Capacitor banks, electronic equipment, motor start capacitors
- Inductive with RC Snubber: LED light drivers, transformers, fans, refrigerators, air-conditioners
FAQ
-
Q: Where can I find more detailed installation instructions and user guidance?
A: For more detailed installation instructions, use cases, and comprehensive guidance on adding/removing the Device to/from a Z-Wave network, factory reset, LED signalization, Z-Wave command classes, parameters, and more, refer to the extended user guide at:https://shelly.link/Wave1-KB-ANZ -
Q: What is the ordering code for this device?
A: The ordering code is QNSW-001X16AU. -
Q: How can I contact the manufacturer for support?
A: You can contact Shelly Europe Ltd. (former Allterco Robotics EOOD) at Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria, Tel.: +359 2 988 7435, E-mail: zwave-shelly@shelly.cloud, Support: https://support.shelly.cloud/, Web: https://www.shelly.com
LEGEND
- Device terminals:
- N: Neutral terminal
- L: Live terminal (110–240 V AC)
- SW: Switch/push-button input terminal (controlling O)
- I: Load circuit input terminal
- O: Load circuit output terminal
- Wires:
- N: Neutral wire
- L: Live wire (110-240 V AC)
- Button:
- S: S button (Fig. 2)
READ BEFORE USE
This document contains important technical and safety information about the Device, its safe use and installation.
CAUTION! Before beginning the installation, please read carefully and entirely this guide and any other documents accompanying the device. Failure to follow the installation procedures could lead to malfunction, danger to your health and life, violation of law or refusal of legal and/or commercial guarantee (if any). Shelly Europe Ltd. is not responsible for any loss or damage in case of incorrect installation or improper operation of this Device due to failure of following the user and safety instructions in this guide.
TERMINOLOGY
- Gateway – A Z-Wave® gateway, also referred to as a Z-Wave® controller, Z-Wave® main controller, Z-Wave® primary controller, or Z-Wave® hub, etc., is a device that serves as a central hub for a Z-Wave® smart home network. The term “gateway” is used in this document.
- S button – The Z-Wave® Service button, which is located on Z-Wave® devices and is used for various functions such as inclusion (adding), exclusion (removing), and resetting the device to its factory default settings. The term “S button” is used in this document.
- Device – In this document, the term “Device” is used to refer to the Shelly Qubino device that is a subject of this guide.
ABOUT SHELLY QUBINO
Shelly Qubino is a line of innovative microprocessor-managed devices, which
allow remote control of electric circuits with a smartphone, tablet, PC, or
home automation system. They work on Z-Wave® wireless communication protocol,
using a gateway, which is required for a configuration of devices. When the
gateway is connected to the internet, you can control Shelly Qubino devices
remotely from anywhere. Shelly Qubino devices can be operated in any Z-Wave®
network with other Z-Wave® certified devices from other manufacturers. All
mains operated nodes within the network will act as repeaters regardless of
vendor to increase reliability of the network. Devices are designed to work
with older generations of Z-Wave® devices and gateways.
ABOUT THE DEVICE
The Device controls the on/off function for one electrical appliance, such as
a bulb, ceiling fan, IR heater, electrical lock, garage doors, irrigation
system. The output contact is potential-free (dry contact), so different power
supply loads can be connected to the Device. It is compatible with push-
buttons and switches (default).
INSTALLATION INSTRUCTIONS
The Device can control a various type of loads (e.g., bulbs) in one electrical circuit. It can be retrofitted into standard electrical wall boxes, behind power sockets and light switches or other places with limited space.
- CAUTION! Danger of electrocution. Mounting/installation of the Device to the power grid has to be performed with caution, by a qualified electrician.
- WARNING! Danger of electrocution. Every change in the connections has to be done after ensuring there is no voltage present at the Device terminals.
- CAUTION! Use the Device only with a power grid and appliances that comply with all applicable regulations. A short circuit in the power grid or any appliance connected to the Device may damage it.
- CAUTION! Do not connect the Device to appliances exceeding the given max. load!
- CAUTION! Do not shorten the antenna.
- RECOMMENDATION: Place the antenna as far away as possible from metal elements as they can cause signal interference.
- CAUTION! Connect the Device only in the way shown in these instructions. Any other method could cause damage and/or injury.
- CAUTION! Do not install the Device where it can get wet.
- CAUTION! Do not use the Device if it has been damaged!
- CAUTION! Do not attempt to service or repair the Device yourself!
- RECOMMENDATION: Connect the Device using solid single-core wires with increased insulation heat resistance not less than PVC T105°C (221°F).
- CAUTION! Before starting the mounting/installation of the Device, check that the breakers are turned off and there is no voltage on their terminals. This can be done with a phase tester or multimeter. When you are sure that there is no voltage, you can proceed to connecting the wires.
Connect the load circuit to the Device I and O terminals. If you are using AC power supply for the Device, connect the Live wire to the Device L terminal, and the Neutral wire to the N terminal as shown on Fig. 1. Connect a switch or a push-button to the Device SW terminal and the Live wire.
- RECOMMENDATION: For inductive appliances that cause voltage spikes during switching on/off, such as electrical motors, fans, vacuum cleaners and similar ones, RC snubber (0.1 µF / 100 Ω / 1/2 W / 600 VAC) should be connected parallel to the appliance.
- CAUTION! Do not allow children to play with the push buttons/ switches connected to the Device. Keep the devices for remote control of Shelly Qubino (mobile phones, tablets, PCs) away from children.
EXTENDED USER GUIDE
For more detailed installation instructions, use cases, and comprehensive
guidance on adding/removing the Device to/from a Z-Wave network, factory
reset, LED signalization, Z-Wave command classes, parameters, and much more,
refer to the extended user guide at: https://shelly.link/Wave1-KB-ANZ
SPECIFICATIONS
- Power supply 110-240 V AC, 50/60 Hz
- Power consumption < 0.3 W
- Max. switching voltage AC 240 V
- Max. switching current AC 16 A
- Overheating protection Yes
- Distance Up to 40 m indoors (131 ft.) (depends on local condition)
- Z-Wave® repeater Yes
- CPU Z-Wave® S800
- Z-Wave® frequency band 919,8 MHz
- Maximum radio frequency power transmitted in frequency band(s) < 25 mW
- Size (H x W x D) 37x42x16 ±0.5 mm / 1.46×1.65×0.63 ±0.02 in
- Weight 26 g / 0.92 oz.
- Mounting Wall console
- Screw terminals max. torque 0.4 Nm / 3.5 lbin
- Conductor cross section 0.5 to 1.5 mm² / 20 to 16 AWG
- Conductor stripped length 5 to 6 mm / 0.20 to 0.24 in
- Shell material Plastic
- Color Blue
- Ambient temperature -20°C to 40°C / -5°F to 105°F
- Humidity 30% to 70% RH
- Max. altitude 2000 m / 6562 ft
OPERATIONAL INSTRUCTIONS
If the SW is configured as a switch (default), each toggle of the switch will
change the output O state to the opposite state – on, off, on, etc.
If the SW is configured as a push-button in the Device settings, each press of
the push-button will change the output O state to the opposite state – on,
off, on, etc.
SUPPORTED LOAD TYPES
- Resistive (incandescent bulbs, heating devices)
- Capacitive (capacitor banks, electronic equipment, motor start capacitors)
- Inductive with RC Snubber (LED light drivers, transformers, fans, refrigerators, air-conditioners)
IMPORTANT DISCLAIMER
Z-Wave® wireless communication may not always be 100% reliable. This Device
should not be used in situations in which life and/or valuables are solely
dependent on its functioning. If the Device is not recognized by your gateway
or appears incorrectly, you may need to change the Device type manually and
ensure that your gateway supports Z-Wave Plus® multi-channel devices.
ORDERING CODE: QNSW-001X16AU
MANUFACTURER:
Shelly Europe Ltd. (former Allterco Robotics EOOD)
Address: 103 Cherni vrah Blvd., 1407 Sofia, Bulgaria
Tel.: +359 2 988 7435
E-mail: zwave-shelly@shelly.cloud
Support: https://support.shelly.cloud/
Web: https://www.shelly.com
Changes in the contact data are published by the Manufacturer at the official
website: https://www.shelly.com