HDL MWC1-KT.10 Curtain Motor
Overview
Curtain Motor (Model: MWC1-KT.10; hereinafter referred to as the “product” or
“device”) is designed to drive curtain track, such as open or close the
curtain cloth. Additionally, the device is compatible with commissioning
software and mobile APP. Upon proper installation and commissioning, it is
able to integrate the device into smart room system, helping end users easily
and conveniently remote control their curtains.
Note : The pictures and illustrations provided in this instruction manual
are for reference purposes only, and the actual product may differ.
Key Functions:
- KNX communication protocol
- Curtain control: Open / close / stop / open or close at specific percentage
- Touch start: The device supports “Touch Start” by default. This means, when users gently pull the curtain cloth towards any direction, curtain motor will be activated to work and automatically complete the preset travel.
- Auto travel limit: After setting the motor travel limit, the motor will automatically complete the pre-set travel.
- Auto modification while detecting obstacles: When single side of curtain cloth encounters obstacles, the motor will automatically modify its travel limit.
- Auto pause while detecting obstruction: When curtain cloth encounters obstruction, the motor will automatically stop running.
- Soft start / stop: The motor slows down before it reaches the travel limit point, which is designed to effectively protect the motor and lengthen its service life, as well as reduce motorized noise.
- When the device starts up for the first time after power off then on, it will automatically proceed travel calibration.
- Factory setting can be restored by commissioning software or programming button.
- Through commissioning software, users can proceed advanced settings for the device, including functional configuration, data backup, data upload or download.
- On-line / Manually update for device firmware
- Compatible with bi-channel or multi-channel remote controllers (optional)
Appearance
Technical Data
Motor input voltage | 100 – 240V AC, 50/60Hz |
---|---|
Motor rated consumption | 22W |
KNX rated voltage | 30V DC |
KNX rated current | 8mA/30V DC |
Motor torque | 1.2 N·m |
Motor rotate speed | 90rpm |
Motor maximum load-bearing | 50kg |
Motor sound level | <30dB ,at silent mode |
Communication protocol | KNX |
Working temperature | -5℃ ~ 45℃ |
Working relative humidity | ≤90%RH, non-condensed |
Storage temperature | -20℃ ~ 60℃ |
Storage relative humidity | ≤93%RH |
Specifications
Dimensions (W X H X D) | 296×71×50.6mm (See Figure 3 – 5) |
---|---|
Net weight | 724g |
Housing material | PC, aluminium |
Installation | Guide rail (See Figure 7 & 8) |
IP degree (compliant with EN 60529) | IP41 |
Insultation grade | F |
Safety Precaution
Danger:
Please do not privately disassemble or replace any parts of the product. Otherwise, it may cause mechanical fault, electric shock, fire or personal injuries.
Warning:
The installation and testing for the product must be carried out by HDL
Automation Co., Ltd. (hereinafter referred to as
HDL) or its appointed service agencies. The electric construction shall comply
with local laws and safety regulations.
HDL will not be responsible for any consequence caused by the inexpert or
faulty installation and wiring methods, which are not in accordance with the
instructions contained in this datasheet.
Please contact HDL after-sales departments or our designated service agencies
for your maintenance service. Product failures caused by private disassembly
are not subject to the warranty.
Caution:
- Before performing any installation or disassembly procedures, any maintenance or cleaning procedures on the device, it is crucial to disconnect the device from all voltage sources. This step is necessary to ensure the safety of the technician and prevent any potential damage to the device.
- Do not use corrosive liquid to wipe the device body, especially the interface, so to avoid damage to the device.
- Do not wipe the device with a damp cloth.
- Prior to performing maintenance or cleaning on the device, disconnect the device from all voltage sources, to avoid electric leakage and electric shock.
- Kindly take note that the installation of the aforementioned device is recommended to be conducted in an indoor environment, with due consideration given to the avoidance of exposure to external factors such as humidity and high temperatures.
- After all of the cables are terminated, check for correct and good terminations.
- Kindly take note that the installation of the aforementioned device is recommended to be conducted in an indoor environment.
- It is strictly forbidden to apply any extra items whose weight exceed the motor or guide rail maximum load-bearing to the curtain track; DO NOT climb the curtain.
- When installing the motor onto the guide rail, be sure to check if the motor has been tightly attached in place. Otherwise, it will cause the motor to fall, resulting in product damage or personal injury.
Wiring
Tips : After all of the cables are terminated, check for correct and good terminations.
Note : In addition to KNX connection, please note to connect the device with 220V AC power supply.
KNX Cable Guide
KNX | KNX Cable |
---|---|
+ | Red |
– | Black |
Installation
Warning: Before performing any installation procedures on the device, it is
crucial to disconnect the device from all voltage sources. This step is
necessary to ensure the safety of the technician and prevent any potential
damage to the device.
Tips : The device should be mounted onto the guide rail. Thus, please
make sure the guide rail has been installed properly.
Step 1. Pull the lock bar out, then slide it in the direction indicated
by arrow 1.
Step 2. Insert the motor shaft to the giude rail.
Step 3. Make sure the motor is tightly attached with the guide rail, then
slide the lock bar back in the direction indicated by arrow 3. In this way,
the motor can be locked.
Note : After installation, check for correct and good terminations.
Before powering on, please ensure the device is completely mounted onto the
guide rail.
Operation
The device is configured with one programming button and indicator, as described below.
Note : All operation and settings described as below should be carried out when the device is running normally.
Basic Operation
Switch Power-on to Quick Start
Operation | Status of Indicator |
---|---|
Connect the device to power supply, then it starts running normally. | Red |
light is on then off.
Test Motor Travel
Operation | Status of Motor |
---|
Reconnect the device to power supply. When it restarts, pull the curtain cloth gently towards any direction.| Curtain motor will be activated to work and automatically complete the preset travel.
Control Curtain Cloth
Function | Operation |
---|---|
Open / close / stop / open or close at specific percentage | Users can achieve |
these remote control through smart panels, remote controllers, mobile APP.
Touch start| The device supports “Touch Start” by default, which can be
enabled or disabled through commissioning software or the remote controller
used. “Touch Start” enabled: When users gently pull the curtain cloth, curtain
motor will be activated to work and automatically travel towards that pulling
direction. “Touch Start” disabled: It requires users to manually operate the
curtain cloth.
Obstruction detection| When curtain cloth or motor encounters obstacles, in
order to avoid damage to the motor or obstacles, the motor will automatically
stop running then modify its travel limit.
Tips : If users need to adjust the motor travel limit, please remove
those obstacles then erase travel limit (see Section 2.3. Erase Travel Limit).
Afterwards, users can proceed re-setting and testing motor travel.
Advanced Settings
Programming Mode
Operation | Status of Indicator |
---|---|
Short press programming button once | Red light is on. |
Set Motor Direction
Tips : Motor direction can be set by the Engineering Tool Software (ETS) or programming button. In this section, it only gives information about the latter.
Operation| Status of Indicator| Status of Motor|
Remark
---|---|---|---
Step 1: Short press programming button once| Red light is on.| /|
Step 2: Short press programming button once again.| Red light flashes slowly.|
/|
Step 3: Long press programming button for 3s.| Red light is on.| /|
Step 4: Long press programming button for 3s again.| Red light flashes then
off.| After successfully set, the motor rotates once.| If no operation on
programming button within 15s, it will exit setting automatically.
Erase Trave Limit
Operation| Status of Indicator| Status of Motor|
Remark
---|---|---|---
Long press programming button for 5s, then immediately release until the
indicator is flashing red.| Red light is on then flashing.| After successfully
set, the motor rotates once.|
Update Firmware
Function| Operation| Status of Indicator| Status of
Motor| Remark
---|---|---|---|---
On-line update| Upgrade device firmware through the Assistant Software.| Red
light flashes.| /|
Manually update| Press programming button, and simultaneously connect the
device to power supply. At this moment, [Manually Update] can be enabled.
Next, proceed firmware updating through the Assistant Software.| Red light
flashes.| /|
Learning Codes in Remote Controller
There are two options for pairing the device with remote controller, as
described below. Regarding operations about further learning codes, please
refer to the datasheet of the remote controller used.
Inside the remote controller used, users will see each side of the battery
compartment has a channel setting button (see Figure 10), which is used for
pairingthe remote controller and the corresponding motor, then receiving and
processing further learning codes. provided as below is for reference purposes
only, and the actual remote controller may differ.
Function| Operation| Status of Indicator| Status of
Motor| Remark
---|---|---|---|---
Option 1: Pairing by programming button| Step 1: Short press
programming button, then release until the indicator is red. At this moment,
the device is entering the status of learning code.| Red light is on.| /|
| Step 2: Press the channel setting button on the remote controller (see
Figure 10).| Red light flashes then off.| After successfully set, the motor
rotates once.|
Option 2: Pairing by switching power-on| Step 1: Switch the device
power off then on. At this moment, the device is entering the status of
learning code.| Red light is on.| /|
| Step 2: Press the channel setting button on the remote controller in 10
seconds (see Figure 10).| Red light flashes then off.| After successfully set,
the motor rotates once.|
Erase Codes in Remote Controller
Operation | Status of Indicator | Status of Motor | Remark |
---|---|---|---|
Long press programming button for 10s | Red light is on then flashing, and then | ||
off | After successfully set, the motor rotates twice. |
Other
Status of Indicator | Status of Motor | Remark |
---|---|---|
Blue light flashes slowly. | The device is abnormal. Please check whether the | |
220V power supply is connected properly. |
Packing List
- Curtain Motor*1
- Terminal block*1
- Power cable*1
- QR code card*1
Note : After unpacking, please check if the product and the parts are complete.
Legal Statement
HDL has all the intellectual property rights to this document and contents
thereof. Reproduction or distribution for third parties are prohibited without
written authorization from HDL. Any infringement of HDL’s intellectual
property rights will be investigated the legal liability.
The contents of this document will be updated as the updates of product
versions or other reasons. Unless otherwise agreed upon, this document is to
be used as a guidance only. All the statements, information and
recommendations in this document makes no warranty expressed or implied.
© 2023 HDL Automation Co., Ltd. All rights reserved.
Update History
The form below contains the information of every update. The latest version
contains all the updates of all former versions.
Technical Support
E-mail :
hdltickets@hdlautomation.com
Website : https://www.hdlautomation.com