HK AUDIO 1007530 Double Flange Plate Instruction Manual

July 3, 2024
HK AUDIO

HK AUDIO - logo DFP Art. No. 1007530
2x Double flange plate
LINEAR 5: L SUB 4000 • L SUB 4000 A / L5 LTS • L5 LTS A
LINEAR 5 MK II 308 LTA • 118 Sub HPA

  • Mounts two LTS (A) / 308 LTA on one L SUB 4000 (A) / 118 Sub HPA to configure a horizontal cluster

Installation Instructions

HK AUDIO 1007530 Double Flange Plate

  • Please read these instructions before installation and keep them for later reference.
  • Heads up: Be sure to observe all the applicable regulations for installation to ceilings, walls and trusses.

HK AUDIO 1007530 Double Flange Plate - fig 2

Installing the DFP

  1. Heads up! Use the DFP for L SUB 4000 / L SUB 4000 A / 118 Sub HPA enclosures only. When installing the DFP, always place the subwoofer (right side up, longer bottom side down) on a stable, level surface, making sure it sits securely. Mount no more than one LTS/LTS A on each attached speaker pole.
  2. Center the DFP on top of the subwoofer and attach it by inserting and tightening the thumbscrew in the enclosure’s threaded M20 sleeve. (Fig. 1)
  3. Insert two standard M20 mounting poles in the DFP’s two threaded M20 sleeves and mount one LTS/LTS A on each (Fig.2).
  4. To minimize undesirable phasing eff ects, simply bring the rear panels in so that they touch. This gives you a 30° opening angle and a horizontal directivity of 140° (Fig. 3 and 4).
  5. To better aim the cluster towards the area you wish to cover, loosen the thumbscrew a little, turn the DFP to the desired position, and tighten the thumbscrew down again, making sure the DFP is firmly fastened.

HK AUDIO 1007530 Double Flange Plate - fig 1

HK Audio®
Postfach 1509
66595 St. Wendel/Germany
info@hkaudio.com
www.hkaudio.com
International Inquiries:
fax +49-68 51-905 215
international@hkaudio.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals