UNI-T UDP6721 Digital Control Power Supply User Manual
- June 24, 2024
- UNI-T
Table of Contents
- UNI-T UDP6721 Digital Control Power Supply
- Product Information
- Usage Instructions
- Warranty Service
- Characteristics
- Specifications
- Front Panel
- Rear Panel
- Packing List
- Operating Environment
- Quick Start
- Display Interface Information
- Remote Communication
- Remote Control Interface & Operating Instructions
- Operating Steps
- Menu introduction of list mode
- Parameter Setting of Delayer Mode
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
UNI-T UDP6721 Digital Control Power Supply
Specifications:
- Product Name: UDP6720 Series Digital Control Power Supply
- Manufacturer: Uni-Trend Technology (China) Co., Ltd.
- Warranty: 1 year
- Trademark: UNI-T
Product Information
The UDP6720 Series Digital Control Power Supply is a brand new product designed and manufactured by Uni-Trend Technology. It features digital control for precise power supply management and is suitable for various applications that require stable power output.
Usage Instructions
Safety Precautions:
Before using the power supply, please read the safety notes provided in the
manual carefully to ensure safe operation.
Warranty Service:
The product comes with a one-year warranty from the date of purchase. If
any defects occur during the warranty period, UNI-T will repair or replace the
product at no additional cost. To avail of the warranty service, contact UNI-T
with details of the issue.
Limited Warranty and Liability:
UNI-T provides a limited warranty for the product, covering repair or
replacement of defective items. The warranty does not cover indirect or
consequential damages.
Copyright Information:
All rights reserved by Uni-Trend Technology (China) Co., Ltd.
Unauthorized reproduction of any part of this manual is prohibited.
FAQ:
-
Q: What should I do if the product malfunctions after the warranty period?
A: If issues arise after the warranty period, contact UNI-T for assistance. They may provide repair services for a fee. -
Q: Can I use this power supply for sensitive electronic devices?
A: Yes, the UDP6720 Series Digital Control Power Supply is suitable for powering sensitive electronic equipment due to its stable output.
Perface
Thank you for purchasing this brand new product digital control power supply.
In order to use this product safely and correctly, please read this manual
thoroughly, especially the safety notes.
Copyright Information
Copyright is owned by Uni-Trend Technology (China) Co., Ltd.
UNI-T products are protected by patent rights in China and other countries,
including issued and pending patents. Uni- Trend reserves the rights to any
product specification and pricing changes.
Uni-Trend Technology (China) Co., Ltd. all rights reserved. Trend reserves all
rights. Information in this manual supersedes all previously published
versions. No part of this manual may be copied, extracted or translated by any
means without the prior permission of Uni Trend.
UNI-T is the registered trademark of Uni Trend Technology (China) Co., Ltd.
Warranty Service
The instrument has a warranty period of one year from the date of purchase. If
the instrument is damaged due to improper operation by the user during the
warranty period, the maintenance fee and the costs caused by the maintenance
shall be borne by the user, and the instrument shall be maintained by the
company for life.
If the original purchaser sells or transfers the product to a third party
within one year from the date of purchase of the product, the warranty period
of one year shall be from the date of the original purchase from UNI-T or an
authorized UNl-T distributor. Power cords, accessories and fuses, etc. are not
included in this warranty.
If the product is proved to be defective within the warranty period, UNI-T
reserves the rights to either repair the defective product without charging of
parts and labor, or exchange the defected product to a working equivalent
product (determined by UNI-T). Replacement parts, modules and products may be
brand new, or perform at the same specifications as brand new products. All
original parts, modules, or products which were defective become the property
of UNI-T.
The “customer” refers to the individual or entity that is declared in the
guarantee. In order to obtain the warranty service, “customer “must inform the
defects within the applicable warranty period to UNI-T, and perform
appropriate arrangements for the warranty service.
The customer shall be responsible for packing and shipping the defective
products to the individual or entity that is declared in the guarantee. In
order obtain the warranty service, customer must inform the defects within the
applicable warranty period to UNI-T, and perform appropriate arrangements for
the warranty service. The customer shall be responsible for packing and
shipping the defective products to the designated maintenance center of UNI-T,
pay the shipping cost, and provide a copy of the purchase receipt of the
original purchaser. If the products is shipped domestically to the purchase
receipt of the original purchaser. If the product is shipped to the location
of the UNI-T service center, UNI-T shall pay the return shipping fee. If the
product is sent to any other location, the customer shall be responsible for
all shipping, duties, taxes, and any other expenses.
Limited Warranty and Liability
The warranty is inapplicable to any defects, failures or damages caused by
accident, normal wear of components, use beyond specified scope or improper
use of product, or improper or insufficient maintenance. UNI-T is not obliged
to provide the services below as prescribed by the warranty:
- Repair damage caused by installation, repair or maintenance of personnel other than service representatives of UNI-T;
- Repair damage caused by improper use or connection to incompatible equipment;
- Repair any damages or failures caused by using power source not provided by UNI-T;
- Repair products that have been changed or integrated with other products (if such change or integration increases time or difficulty of repair).
The warranty is formulated by UNI-T for this product, replacing any other
express or implied warranties. UNI-T and its distributors refuse to give any
implied warranty for marketability or applicability for special purpose. For
violation of the warranty, repair or replacement of defective products is the
only and all remedial measure UNI-T provides for customers.
No matter whether UNI-T and its distributors are informed of any possible
indirect, special, occasional or inevitable damage in advance, they assume no
responsibility for such damage.
Safety Information
Warning
Caution:
To avoid possible electric shock and personal safety problem, please follow
the instructions below.
Disclaimer
Please read the following safety information carefully beforestarting to use
the instrument. Uni-Trend will not be responsible for the personal safety and
property damage caused by the user’s failure to comply with the following
terms.
Instrument Grounding
To prevent the risk of electric shock, please connect the power ground wire.
Operating voltage
Please make sure operating voltage under rated range of 10%, to avoid damage
the instrument.
Input voltage
Please use AC 110V~220V 50/60Hz AC power supply, use national approved power
cord and make sure insulating layer is in good condition.
Inspecting the wire of the instrument
Inspecting the condtion of the insulating layer of the wire, check if it is
broken, bareness or workable. If the wire is damaged, please replace it before
connect with the instrument.
Fuse wire of the instrument
Only allowed use the dictated specification fuse wire.
Over-voltage protection
Please make sure the instrument is not over-voltage(such as the voltage
casused by thunder. To prevent operating personnel away from electric shock.
Do Not
open the cover when the instrument is inoperating
Please do not operating the instrument when open the cover and do not change
the internal circuit.
Do Not
touch live part
When the instrument is in operating, do not touch the bare connect wire, spare
input terminal and the circuit is in testing. When the instrument is over DC
60V or AC 30V, be careful electric shock.
Do Not
use the instrument in an explosive atmosphere
Do not use the instrument in flammable and explosive gas, steam or dusty
environment.
The use of any electronic equipment in such an environment is a risk to
personal safety.
Safety Mark
Environment-friendly Use Period
EFUP is the period of time before any of the RoHS substances are likely to
leak out, causing possible harm to health and the environment. EFUP of this
instrument is 40 years, it should be recycling system when exceed 40 years.
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
****Must not be discarded in the trash can.
Product Series
UDP6720 Series Digital Control Power has two models, UDP6720 and UDP6721.
Output range as follows,
Model | Output Range |
---|---|
UDP6720 | 0-60V,0-5A, 0-100W |
UDP6721 | 0-60V,0-8A, 0-180W |
Characteristics
- Fully digital control
- High resolution 10mV/1mA in full range
- Low ripple and noise
- Software cailbration
- Smallest outline
- High-definition LCD display
- Remote Sensecompensaton
- Support RS-232 communication
- Intelligent fan regulation
- Rated voltage and current output·
- High-reliability: OVP(over voltage protection)/OCP(over current protection)/OTP(over temperature protection)
- Output on/off control
- High performance-price ratio
- Storage for 3×200 preset voltage and current output
- Support List Mode(Time Function) and Delayer Mode
Basic Performance
UDP6721/UDP6721 digital control power supply with widest voltage and current
range, it can applied in many fields. Take UDP6720 for example, with max power
100W and ouput adjustable in 60V/5A, auto control voltage and current slew
rate, power rate up to three times rapid than other similar products. One
instrument can replace three models (60V×1.6A/32V×3A/20V×5A), save your repeat
investment.
Example
Take UDP6720 for example,set output voltage as 60V, because the max power of
UDP6720 is 100W, so the max output current is 100W/60V=1.66A. When output
voltage down to 20V, the max output current turns to 100W/20V=5A. The max
output current of UDP6720 is 5A, if the current output voltage continue
decrease , the max output current of UDP6720 still as 5A.
Specifications
Specification | UDP6720 | UDP6721 | |
---|---|---|---|
**** Output Range | Voltage | 0~60V | 0~60V |
Current | 0~5A | 0~8A | |
Power | 100W | 180W | |
**** Load Regulation | Voltage | <0.01%+3mV | <0.01%+5mV |
Current | <0.01%+3mA | <0.01%+5mA | |
Power Supply Regulation | Voltage | <0.01%+3mV | <0.01%+5mV |
Current | <0.1%+3mA | <0.1%+5mA | |
Programming Accuracy | Voltage | <0.05%+10mV | <0.05%+10mV |
Current | <0.2%+2mA | <0.3%+5mA | |
**** Read-back Accuracy | Voltage | <0.05%+10mV | <0.05%+10mV |
Current | <0.2%+2mA | <0.3%+5mA | |
**** Ripple and Noise | Voltage | <2.0mV rms | <5.0mV rms |
Current | <5.0mA rms | <8.0mA rms | |
Dimension | W×H×D | 87×174×255(mm) | 87×174×255(mm) |
Weight | Net | <2.5Kg | <2.5Kg |
Front Panel
Rear Panel
Packing List
Befor use the instrument, please,
- Check whether the appearance is damaged, scratched or has other defects;
- Check with packing list to confirm that accessories has no loss.
If there have any problem, please contact with Uni-Trend Instrument Sale Department or the distributor.
Components | Quantity | Remarks |
---|---|---|
The instrument | 1 | The model is subject to the actual order |
3C power line | 1 | |
250V/3.15A spare fuse UDP6720 | 1 | |
250V/5A spare fuse UDP6721 | 1 | |
User’s Manual /Upper-computer software | 1 | Electronic file,download from the |
official website
Requirments of Power Supply
UDP6720 series digital control power supply can only use under the power
supply terms as the table below.
Parameter | Requirements |
---|---|
Voltage | AC110/ 220(±10%)V |
Frequency | 50/60Hz |
Fuse UDP6720 | AC110V input voltage:250V/3.15A |
Fuse UDP6721 | AC110V input voltage:110V/5A |
Factory supply three-core power cable, please make sure power cable of three phase socket is connect with ground before use.
- This instrument 110V is select fuse of 250V/3.15A or 250V/5A, the specification is 5× 20mm,it all set and equip with spare fuse of 250V/3.15A or 250V/5A in fuse box before the product leave the factory.
- Please remove the external power cable before replace the fuse, open the fuse socket slot under the power supply plug, take out the old fuse and replace the new fuse into it, after that the instrument can be used normally.
Warning: Do not use power cable with any signs of damage to avoid danger!
Operating Environment
UDP6720 series digital control power supply can only use in normal termperature and low condensing zone. The general environmental requirements of the instruments is listed as the below table.
Operating Environment | Environmental Requirements |
---|---|
Temperature | 0℃~45℃ |
Humidity | 20%~80%(non- condensation) |
Storage temperature | -20℃~70℃ |
Altitude | ≤2000 meter |
Pollution degree | 2 |
Explanation: In order to guarantee the accurancy of measurement, it is suggested that turn on the instrument half an hour before operating.
Cleaning
To prevent from the risk of electric shock, please pull out power line befor
cleaning.
Please use a clean cloth dipped in clean water to clean the cover and panel.
Do not clean the inside of the instrument.
Caution: Do not use solvents (alcohol or gasoline etc.) to clean the
instrument.
Quick Start
Apparance Inspection
- Check out the instrument is in a good condition during the delivery. If there have any problem, please contact with Uni-Trend Instrument Sale Department or the distributor.
- Confirm whether the AC input voltage of UDP6720/UDP6721 comply with the standards of your country or region.
Notice: Use 110V/220V switch on the rear panel to select input voltage. After confirming the above matters, power on the instrument.
Voltage Setup
Current Setup
Enable Output
- Push to enable power output function and the indicator light will be green. In the mean time, C.V/C.C indicator light will be green or red light according to the different output mode;
- OUTPUT key indicator light will be off when OUTPUT function is disable. C.V/C.C indicator light will also be off.
Keyboard Lock
Lock keyboard function is prevent unauthorized worker or operating personnel
form making accident operation. To avoid damage the device under test.
- Push Lock key to enable lock keyboard function and the indicator light will be green. Lock symbol will shown on the top of screen.
- In lock status, long push Lock key to unlock the function and indicator light will be off. Lock symbol will also disappear on the screen.
OVP Function
OCP Function
Bepper Switch
Brightness Setup
Memory Group Setup
Memory Group Voltage/Current Setup
Set the specific output voltage/current point and select memory key M1~M3,
push it to save the current setting. When user need to call the stored output
voltage/current, enter the setup interface to select the specific memory group
and then push memory key M1~M3 to call the specific stored output
voltage/current.
When user call the stored output voltage/current, the corresponding memory key
will indicate green light.
Output Mode Setup
Language Setup
Display Interface Information
- Push to enter the setup interface;
- Use left, right arrow key to select the IO Information option;
- RS232 configuration information will shown on the right side of the screen.
About
Remote Sense Compensation Setup
Before use Remote Sense compensation function, take off short connect terminal
on the Remote Sense compensation terminal, connect load voltage positive
terminal to compensation terminal S+ and load voltage negative terminal
connect to compensation terminal S-. And then enable power output to turn on
Remote Sense compensation function. That is, the output voltage of the DC
power supply is the voltage of the load terminal.
Notice: Remote Sense compensation voltage should less than 0.6V.
CV/CC Operating Mode of Power Supply
Power supply can automatic transfer constant voltage/current function.
Power supply can ongoing switch the constant voltage/current function
dependends on load fluctuation.
If the current load is on the constant voltage mode, power supply provide a
controlled output and voltage. As the load resistance value decreases, the
output voltage remains constant until the output current increases to greater
than the preset current value, which it will convert operating mode. If the
power supply turn into constant current output, the output voltage will
decrease proportionally according to resistance value of the load. When the
current value less than the set value, power supply will back to the constant
voltage mode.
Troubleshooting
Power supply is no output
- Check the set value of voltage and current is zero or not. If it is, reset the voltage and crrent value.
- OUTPUT indicator light is light on or not. If it is, push OUTPUT key to enable the output function.
- Check OVP,OCP,OTP function is activated or not. If it is, reset the value of OVP, OCP and wait the power supply remain stable to turn the output function.
- If Remote Sense compensation function has been enabled, check the line loss of output cable is excced thelimit value or not. If it is, replace the output cable or decrease the output current, and then try to enable the power supply again.
The keyboard is not work
Check Lock indicator light is light on or not. If it is, please refer to Lock
section to reset again.
Remote Communication
The installment and startup configuration file
- Download the installment file from official website;
- Turn on power supply;
- Connect the control line of RS232 to control power supply;
- Activate the remote controlling application program;
- Click Euqipments List, and double-click the power supply symbol of UDP6720 or UDP6721 to enter the remote communication interface.
Remote Control Interface & Operating Instructions
List Mode (Time Function) and Delayer Mode
List Mode
List mode can setup multiple testing program, it can set 48 groups of
independentant voltage, current and parameter of output duration time.
Delayer Mode
Delayer mode can setup multiple testing program to control output status,
which is set count to control output status is on or off, and the time
interval of switch can also set by point to point. Delayer mode can set 48
output status groups to control parameter.
Output parameter of list/delayer mode can all store in internal storage. It
has powerdown function. Storage space for each group is 48
Operating Steps
- Push power supply switch to turn on the instrument;
- Turn on list mode/ delayer mode:
Parameter Setting of List Mode
Menu introduction of list mode
Cycle index: It divide into maximum inf and 1-999. A cycle period is
start form setup origin point to end point. Push rotary knob to adjusting
parameters.
Count: It can set “001” – “048”, which is excute group from origin point
to end point. Push rotary knob to adjusting point. Notice: each voltage,
current and time is a point.
Origin point: It can adjust “000”-“047”, which is start from origin point
to run. (“origin point” value + “count” value ≤ 048)
Mode: It divide into three mode stop, run and pasue, it can not be set;
Pause presents power supply is not output at the current;
Run presents power supply is operating;
Pause presents power supply is paused;
This curve figure can direct present the setting parameter of list mode.
Notice: clear select function is eliminate the corresponding group of origin point to count.
Parameter Setting of Delayer Mode
Mode: It divide into three mode stop, run and pasue, it can not set;
Stop presents power supply is not output at the current;
Run presents power supply is operating;
Pause presents power supply is paused;
Notice: In pause and run mode, interface can not be adjust; pause only
shown when protection function is enabled.
Notice: clear select function is eliminate the corresponding group of origin point to count.
UNI-TREND TECHNOLOGY (CHINA) CC.1 LTC.
No. 6, Gong Ye Bei 1st Road, Songshan Lake National High-Tech Industrial
Development Zone, Dongguan City, Guangdong Province, China
Read User Manual Online (PDF format)