Introduction

Thank you for purchasing the OFPG CO2 meter board XL! This board detects the amount of CO2 particles and measures temperature and relative humidity. In order to use the product correctly, it is necessary to thoroughly read all safety instructions and considerations mentioned in this manual.

Product overview

This product is multifunctional and detects the amount of CO2 particles (in parts per million, PPM), measures the temperature (in degrees Celsius) and the relative humidity (in percentage). The CO2 board is used in areas where detection of air quality is important, such as in industrial production halls, hotels, shops, offices,  department stores, laboratories, schools, hospitals, etc.
Product features:

  • Unique design with a sturdy plastic housing with long service life
  • The high degree of precision, high measurement resolution
  • Operates on 220-230V AC mains (with supplied adapter) for continuous use
  • Large numerical displays with digital LED: clear and intuitive
  • Freely adjustable limits for CO2 alarm
  • High-quality European SenseAir sensor for precise measurements

Product characteristics

Measurement  range

| C O 2 c o n c e n t ra t i o n| 0 – 9999 PM
---|---|---
T e m p e ra t u re| -10°C – 100°C
Relative humidity| 0 – 99,9%

P recision

| C O 2 c o n c e n t ra t i o n| ± 70 PPM en ± 3%
T e m p e ra t u re| ± 0,6°C (max. ± 1,5°C)
Relative humidity| ± 3%

Res o l u t i on

| C O 2 c o n c e n t ra t i o n| 1 PPM
T e m p e ra t u re| 0,1°C
Relative humidity| 0,1%
Repeatability| ≤ ± 0,5%
Response t i m e| 10 seconden
O p e rating limits| 0°C – 50°C, 0% – 90% non-condensing humidity
St o rage limits| -30°C – 70°C, 0% – 90% non-condensing humidity
P o w e r su pp l y| AC 220-230V converted to DC 9V 2A power adapter
Maximum                   power consumption| 9V * 350mA
Dimensions (W x H x D)| 388mm x 288mm x 43mm
Weight| 2420g

Board overview and description of buttons

Front panel:

Brandbeveiliging OFPG CO2-BORD Handleiding - Board overview and description
of buttons

  1. CO2 value in parts per million (PPM)
  2. Temperature value in degrees Celsius (°C).
  3. Relative humidity in %.
  4. Air quality indicator gauge:
    • Excellent – green: 0 PPM – 599 PPM
    • Normal – yellow: 600 PPM – 1199 PPM
    • Weak – red: 1200 PPM – 9999 PPM

Back panel:

  1. Brandbeveiliging OFPG CO2-BORD Handleiding - Back panelMODE Set CO2 alarm value
  2. ▲ Increase alarm value
  3. ▼ Decrease alarm value
  4. The alarm on/off
  5. °C/°F Change between temperature unit
  6. Power adapter connection

Usage instructions

Starting up

To activate the board, connect the power adapter supplied to the power adapter socket on the board (see section 4). Preferably activate the device in an already well-ventilated room so that the calibration can proceed correctly. The board will then light up and initialize and calibrate for 7 seconds. After these 7 seconds, the board will display the current ambient values in the appropriate fields.

Installation

The board can be installed on the wall using the plugs and screws provided.

Setting the alarm

Press the “MODE” button on the back of the board to enter the setting mode. The initial alarm value is set to 1200PPM. Use the ▲ and ▼ buttons to set the desired alarm value. Then press the “MODE” button again to complete the setting of the alarm value. Use the key to activate or deactivate the alarm.

Calibration and calibration period

The unit will calibrate for 7 seconds on activation. Preferably activate the device in an already well-ventilated room so that the calibration can proceed correctly.
The board will continue to calibrate itself in the background. The most correct values are reached after a few hours.

Important considerations and warning

  • The electronic sensors and components in this unit are precision electronics. The product should at all times be kept away from water, fire, flammable oil, gas and locations with strong electromagnetic fields in order to avoid influence on and damage to the product.
  • Avoid shocks and sudden impacts to the device.
  • Only use the original power adapter supplied.
  • Do not use strong detergents to clean the device. Corrosive liquids can seriously damage the device and its components. Only use a damp cloth with clean water for cleaning.
  • Never try to repair the product yourself.
  • Never try to open the device.

Environment

This product should be recycled according to the applicable local regulations for the disposal of electronic and electrical equipment. At the end of the product’s life cycle, this product must not be disposed of in the normal household waste. Do not incinerate.

Declaration of conformity

This product complies with the applicable CE and RoHS standards.

EMC 2014/30/EU ; EN 61326-1:2013

RoHS 2.0 2011/65EU Annex II (EU) 2015/863 + 2017/2102
IEC 62321-1:2013
IEC 62321-2:2013
IEC 62321-3-1:2013
IEC 62321-3-2:2013
IEC 62321-4:2013
IEC 62321-5:2013
IEC 62321-6:2015
IEC 62321-7-1:2015
IEC 62321-7-2:2017
IEC 62321-8:2017
RBT201116017EC-1
RTB201116017RC-1
HT-2008
Made in China

Online Fire Protection Group BV
Wayenborgstraat 5 2800 Mechelen Belgium.
www.brandbeveiligingshop.be
www.protectionincendieshop.be
www.brandbeveiligingshop.nl

Service:
info@brandbeveiligingshop.be
info@protectionincendieshop.be
info@brandbeveiligingshop.nl
+32 (0)15 69 00 60
+ 31 (0)30 820 10 9

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals