waythcan ISC-BA02 Breath Alcohol Analyzer User Guide
General
This manual introduces the functions and operations of the Breath Alcohol
Analyzer (hereinafter referred to as “the Analyzer “).
Model
DHI-ISC-BA02
Safety Instructions
The following signal words might appear in the manual.
Signal Words | Meaning |
---|---|
DANGER | Indicates a high potential hazard which, if not avoided, will result |
in death or serious injury. | |
WARNING | Indicates a medium or low potential hazard which, if not avoided, |
could result in slight or moderate injury. | |
CAUTION | Indicates a potential risk which, if not avoided, could result in |
property damage, data loss, reductions in performance, or unpredictable
results.|
TIPS| Provides methods to help you solve a problem or save time.|
NOTE| Provides additional information as a supplement to the text.|
About the Manual
- We are not liable for losses incurred due to operating the product in ways that are not in compliance with the manual.
- The manual will be updated according to the latest laws and regulations of related jurisdictions. For detailed information, see the paper user’s manual, use our CD-ROM, scan the QR code or visit our official website. The manual is for reference only. Slight differences might be found between the electronic version and the paper version.
- All designs and software are subject to change without prior written notice. Product updates might result in some differences appearing between the actual product and the manual. Please contact customer service for the latest program and supplementary documentation.
- There might be errors in the print or deviations in the description of the functions, operations and technical data. If there is any doubt or dispute, we reserve the right of final explanation.
- Upgrade the reader software or try other mainstream reader software if the manual (in PDF format) cannot be opened.
- All trademarks, registered trademarks and company names in the manual are properties of their respective owners.
- Please visit our website, contact the supplier or customer service if any problems occur while using the Analyzer.
- If there is any uncertainty or controversy, we reserve the right of final explanation.
About the Device
Please take attention that changes or modifications not expressly approved by
the party responsible for compliance could void the This device complies with
Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Product Information
General Information
DHI-ISC-BA02 is a key chain breath alcohol analyzer which is convenient to
carry and use at all times. The fuel cell sensor provides superb accuracy and
repeatability. OLED shows results with 3 decimals. Alarm threshold is preset
and there is low voltage indication.
Alcohol and its Effects on the Human Body
Alcohol is absorbed into the bloodstream from the mouth, throat, and stomach.
Since alcohol is present in the blood, it can be detected in human breath.
Alcohol in the bloodstream cannot undergo digestion and chemical reactions.
Alcohol in the bloodstream passes through the membrane of the lung air sacs
(alveoli) into the air as the blood flows through the lungs. The concentration
of alcohol in the alveolar air is directly related to the concentration of
alcohol in the blood. As the alveolar air is exhaled, the breath alcohol
analyzer can detect the alcohol in it. The alcohol concentration in the breath
is related to the alcohol concentration in the blood. Therefore, a person’s
BAC can be determined by measuring the alcohol in the breath. The ratio of
breath alcohol to blood alcohol is usually estimated to be 2,100:1. All in
all, 2,100 milliliters (ml) of alveolar air will contain approximately the
same amount of alcohol as 1 ml of blood.
Alcohol is a Chemical Substance
Alcohol is a kind of chemical substance (ethanol or ethanol) produced by the
fermentation of grapes or grains. Alcohol is absorbed directly into your
blood. From your blood, the fluids in your body tissues absorb alcohol. Your
brain is made up of a lot of fluid and will absorb a lot of the alcohol you
drink. Your liver eliminates the absorption of alcohol at its speed, and
nothing you eat or drink can accelerate this process. Your liver does this by
oxidizing alcohol (converting it into water and carbon dioxide).
The Way Alcohol Affects the Human Body
Alcohol is a depressant, which has a releasing effect on the muscles in your
body. Alcohol makes your eyes’ muscles relaxed and hard to focus. Blurred
eyesight, double vision even slower brain activity will occur. In conclusion,
alcohol has such a bad influence on your judgment, responsiveness, and
coordination. Divide the harm of alcohol into two categories below: Eyesight &
Mental
Eyesight harm
- Narrow your eye horizon
- Damage your depth perception
- Decrease your night vision
- Increased your sensitivity to glare
Mental harm
- Become reckless and conceited
- Hard to keep balance or respond in time
- Difficulty in making decisions or judgments
The Way Alcohol Affects Driving
Eyesight and brain, as the most important factors in driving safely, will be
damaged by drinking. So if you drink and drive, you are likely to be involved
in a serious or fatal collision then damage your valued life! And nothing else
can replace its function. Only time can make it. Here comes the effects of the
specific alcohol concentration.
BAC| Effects
Slight happiness, not apparent sadness; lack
---|---
0.02-0.03%| of sense of shame; some individuals may get
| Impairment.
| Some individuals may get some minor
impairment of reasoning and memory;
0.04-0.06%| feeling of happiness, relief, and warmth; under this concentration
of alcohol, driving skills may be negatively influenced.
| Judgment and discipline are impaired.
0.07-0.09%| Caution, reason, and memory are impaired; slight impairment of
balance, speech, vision, reaction time, and hearing. Feeling of happiness;
under this or higher
the concentration of alcohol, driving skills are always negatively influenced.
| Significant impairment of motor
0.10-0.12%| coordination and loss of good judgment.
| Balance, vision, reaction time, speech, and hearing will be impaired.
Feeling of happiness.
0.13-0.15%| Happiness is reduced and sadness (anxiety, restlessness) starts to
appear. Gross motor impairment and lack of physical control.
| Fuzzy vision and major loss of balance.
BAC
0.16-0.20%
| Effects
Sadness predominates. Nausea may appear.
---|---
0.25%| Cannot walk alone without help. Total mental confusion. Sadness with
nausea and some vomiting.
0.30%| Consciousness Loss.
0.40% and higher| The onset of coma. Possible death of respiratory arrest.
WARNING
Driving after drinking is not safe. It is safest to drive when you have no
alcohol left in your bloodstream.
Checking List
After receiving your product, check against the table below. If there are any
problems, contact the after-sales service personnel.
Order
1
| List
Overall packaging
| Appearance| Description Obvious damage
---|---|---|---
Packaging| Accidental impact
Accessories (list of accessories on warranty card)| Complete or not
2| Host| Appearance| Obvious damage
Model| Whether consistent with the order
Components
Breath alcohol analyzer
| Unit
Set| Quality 1| Image
---|---|---|---
Blow tube| Piece| 5|
Battery| Section| 1|
User’s manual| Copy| 1| —
Specification
Parameter Model | Description DHI-ISC-BA02 |
---|---|
Sensor | Fuel Cell |
Test Range | 0–2.00 mg/L; 0–0.400% BAC; 0–4.00 g/L; 0–440 mg/100 mL |
Display | OLED |
Accuracy | ± 0.010% BAC at 0.050% BAC |
Warm Up Time | Less than 5 s |
Operation Condition | Temperature: –10 °C to 50 °C |
Resolution | 0.001% BAC |
Battery | 1 x 1.5 V AAA |
Dimension | 66 mm x 47 mm x 19 mm |
Weight | 35 g |
Appearance and Screen
Appearance
No. | Description | No. | Description |
---|---|---|---|
1 | Breath Sample Outlet | 4 | Indicative Light |
2 | Screen | 5 | Breath Sample Inlet |
3 | Button | 6 | Battery Cover |
Screen
N.
N o| Description
---|---
1| Battery Capacity
2| Measurement Unit
3| Test Result
Meaning of Display Contents
Display Contents | Meaning |
---|---|
0.055 | Breath test rresult |
4 digits after starting For example:1988 | Residual testing times before next |
recalibration
WARM| Warming up
CALIB| Calibration
BLOW| Please blow
CALC| Calculation
LOW POWER| Battery low
LOWER POWER
Auto Power Off
| Battery low and power off
APP MODE| App working mode
K| Constant conversation value between BrAC and BAC
Device Operation and Configuration
Device Operation
Step 1 Install the battery and blow tube to the Analyzer. Aim at the blow tube and blow continuously until you hear “Beep” from the inside of the Analyzer.
Step 2 Press and hold the button to power on the Analyzer and set the alarm threshold.
- When the test result is lower than the set alarm threshold, the indicator light shows green, the specific value will be displayed on the screen
- When the test result reaches or exceeds the alarm threshold, the indicator light shows red, and the buzzer emits a rapid alarm sound.
Step 3 Press and hold the button for more than 3 s to power off the Analyzer.
- If blowing is interrupted,the red indicator is solid on.
- If there is no operation for a long time, the device will automatically power off.
Device Configuration
-
Entering the configuration interface
-
Setting CALIB
When the remaining number of tests is 0, it will prompt Please calibrate CALIB. Cotact after-sales person for calibration. -
Setting Unit
Select the unit from %BAC, ‰BAC, g/L, mg/L, and mg/100mL . It is %BAC by default
-
Setting ALM
Set the alarm threshold. It is 0.050%BAC by default
-
Setting MODE
Select the working Mode from STANDARD, ECO, and DEMO.- STANDARD: Standard mode (default)
- ECO: Economy mode
- DEMO: Demonstration mode
-
Setting K
Adjust the conversion coefficient of breath alcohol content and blood alcohol content. This function is designed for maintenance -
Setting CLEAN
Clear the used times This function is designed for maintenance -
Setting MIC
Set sensitivity level of blow. It ranges from 1 through 5. It is 2 by default
-
EXIT
Press and hold the button to exit the configuration interface, and the current program version is displayed
App Operation and Configuration
Search for “Alcotecit” in Google Play or Apple Appstore, and connect the Analyzer to the mobile phone app through Bluetooth.
App Operation
Step 1 Download the app.
Step 2 Enable Bluetooth on your smartphone and open the app.
Step 3 Turn on Analyzer, and it will automatically search for the
Bluetooth of the phone. After the connection is successful, APP MODE page is
displayed on the screen of the Analyzer
Step 4 Tap START on the app, and then keep blowing into the mouth of the blow tube until hearing a “beep” sound. The test result is displayed on the app.
App Configuration
-
Configuration page
-
UNIT setting
-
ALM setting
-
MODE setting
Troubleshooting
Problem | Possible cause | Solution |
---|
The Analyzer cannot strat normally.
| The battery is not installed correctly.| Install the battery according to
the positive and negative polarity.
The battery is much low.| Replace with a new battery.
Circuit failure.
| Contact distributors or manufacturers for maintenance.
About Us
Company Name Zhejiang HuaJian Technology Co., Ltd.
Company Address 4th Floor, Building 6, No.1181 Binan Road,
Change Subdistrict, Binjiang District, Hangzhou, Zhejiang Province
Service Hotline 400-672-8166
Company E-mail hszj@dahuatech.com