WellsCare IASO-SP1 Dual Wavelength Infrared Light Device User Manual
- June 6, 2024
- WellsCare
Table of Contents
WellsCare IASO-SP1 Dual Wavelength Infrared Light Device
Safety Precautions
Warning
- If the device is disassembled by the user, no replacement or refund is provided.
- Do not stare directly into the laser. This may cause blindness.
- The device should not be used by pregnant women and children under the age of 13.
- The recommended usage time is 30 minutes per session, up to 3 sessions per day. May cause burns, skin irritation and allergic reactions to sensitive skin.
- Patients with cardiovascular disease, kidney disease, cancer, or diabetes should not use this device.
- Keloid patients and anti-inflammatory drug users should not use this device.
- Patients with hypersensitive skins, hematuria, or hypertrophic scar marks should not use this device.
- Do not use if you have sensitive skin with allergies. It may cause skin irritation.
- Do not use with other medical devices or electronics such as wearable electronic medical devices, life support electronics, heartbeat aids, electromagnetic generating devices, etc.
- This device contains a built-in battery. External pressure, impact, heat or fire may cause explosion. For example, do not place this device close to or inside of a stove, microwave, heat cooker or high-pressure container.
Caution
- Please use and store in a dry place, without water and moisture.
- Avoid external vibration or impacts when storing, using or carrying the device.
- Read the Usual Manual in case of damage, malfunction, or non-operation.
- Attach the laser surface tightly onto the body area for complete contact with the device.
- Do not use on deep wounds or bleeding wounds.
- This is a multiple wavelength infrared light therapy device manufactured by WellCare. Use the product only for the purposes that it is intended for. Use the device with the genuine.
- Do not force the device into the charger’s port for recharge. It may damage the charging port.
- Using charging cables other than the one included in the package may cause damages to the product.
- Do not use the device with cosmetics, cream, gel, or ointment that are not manufactured by WellCare.
- The heat you may feel from the device is not produced by the battery but is the normal heating function of the device.
Liability
- We do not take any responsibility for any problem or damage caused by user’s carelessness.
- We do not take any responsibility for any problems or damage caused by the user disassembling and modifying the device.
Product Introduction
Low Level Laser, also called LLL or cold laser, refers to laser with S00mW wavelength or lower. Based on various clinical research and studies, the low level laser therapy (LLLT) is known to help with both chronic and acute pain relief and treatment.
Especially, the 600nm-1000nm laser wavelength effectively works for pain relief, blood flow improvement, vasodilation, lymph node stimulation, cell activation by its biochemistry mechanism. Our product is a compact wearable laser device that emits dual wavelengths, 650nm and 830nm. It is developed as an everyday home care cold laser device that anyone can use as per their convenience to shoulders. This mechanism is known to promotes generating ATP(Adenosine Triphosphate) cells that make energy from the body and protein.
- This is a healthcare massage device with investigate wavelength infrared irradiation and vibration functions.
PRODUCT SPECIFICATION
PRODUCT DISCRIPTION
main device
Caution · For the first time use after purchase, charge for a sufficient time before use.
- Surrounding 4 output ports emit 650 nm wavelength laser.
- Warranty is not provided for damages caused by incorrect use of the charger.
- Charge for over an hour, if the device has not been use for more than a week.
ACCESSORIES
- Hydrocolloid Adhesive Patches
- Band
- Charging Cable
- User Manual
How To Use
MAIN DEVICE
- Press and Holding the button on the sidefor2 second’s powers up the device with an alarm sound. A blue light will be displayed to indicate standby mode. Press and HoldingthebutlDn agpin for2secondstumsoffthedevice.
- Thedevicestartsoperatingand its modes can be changed by pressing the button on the side while the device ison (blue light).
- The butlDn maynotoperalE if the it is pressed from the top.
- Mode 1 (Laser Only) Pressing the button once from the Stand-by mode, will initiate the laser only function.
- Mode 2 (Laser+c.ontinuousVibration) Pressing the button twice from the Stand-by mode, will initiate the laser with continuous vibration function.
- Mode3(Laser+Pulse\/ibration) Pressingthe button Three times from the Stand-by mode, will initiate the laser with pulse vibration function.
When the battery is low
- When the battery is less than 10%, the device vibrates with flashing LED light This is not an operation error. Simply turn off the device and recharge it
- When charging, red LED light turns on, Start using the device when it turns to green, which means that the device is fully charged.
HOW TO USE THE ACTIVITY BAND
Insert the device from the back of the activity band with the buttnn aligned to the narrower part of the device insert on the band. Slide the device first into the narrower part of the band and fasten. The button may get damaged internally if it is not correctly placed into the narrower part of the device insert on the band.
How to insert the device after wearing the band
Make sure to slide the charging port area of the device into the band first
after placing the band around your knee or wrist. Then, carefully fasten the
button area of the device into the other side of the band.
It is recommended to wear the activity band first after adjusting its length
to fit your knee or wrist before inserting the device.
HOW TO CHARGE THE DEVICE
When charging the device directly with a charging cable
Make sure to check the shape of the cable and the charging cradle port before
inserting the cable into the port.
Why won’t the device charge?
- Make sure that the pins inside the charging cradle are intact.
- Make sure to insert theS-pin charging cable into the charging port of the cradle to the correct direction.
- Make sure to insert the devices in the charging cradle in the correct position.
HOW TO USE ADHESIVE PATCHES
The patches are made of hydrocolloid material and do not cause irritation for most skin types. However, if you are allergic to hydrocolloid, refrain from using the patches.
- Open the pouch and take out a sheet of adhesive patches.
- Attach the adhesive patch, carefully aligning it with the device starting from the red part of the patch.
- Remove the protective film by peeling it off from the small protruding edge. Then, attach the device on the desired place on your body.
Note while using the Adhesive Patches
- Please note that the adhesivity of the patches may deteriorate if exposed for a prolonged time.
- Make sure to clean and dry the skin surface before attaching the device for the best result.
- Do not attach a patch on top of a used patch. Remove the used patch from the device before attaching a new one.
Troubleshooting
Please read the manual thoroughly before use. Please follow all the steps above before contacting the service center.