italtecnica Brio 2000 Tank Flow Switch Instruction Manual

October 27, 2023
italtecnica

2000 Tank Flow Switch
Instruction Manual

Brio 2000 Tank Flow Switch

  • TARTS AND STOPS THE PUMP AUTOMATICALLY WHEN THE TAPS ARE OPENED AND CLOSED. PROTECTS AGAINST DRY OPERATION AND PUMP BLOCKAGE IN CASE OF PROLONGED NON-USE.

SAFETY INFORMATION

Installation reserved to specialised professionals
Disconnect the electrical power supply before all works
INSTALLATION WITH SUBMERSIBLE OR EXTERNAL PUMP

italtecnica Brio 2000 Tank Flow Switch - icon1

ALLOWED INSTALLATION POSITIONS

italtecnica Brio 2000 Tank Flow Switch - icon2 INSTALLATION WITH BYPASS FOR HIGH FLOW RATES
italtecnica Brio 2000 Tank Flow Switch - 1 DO NOT INSTALL IN TRAPS

italtecnica Brio 2000 Tank Flow Switch - 2

ALLOWED CHECK-VALVE POSITIONS

italtecnica Brio 2000 Tank Flow Switch - 3

SUCTION FILTER RECOMMENDED

italtecnica Brio 2000 Tank Flow Switch - 4

USE ONLY WITH WATER, MAX SALINITY 0.05%

ELECTRICAL CONNECTION AND PROVISIONS FOR CABLES

italtecnica Brio 2000 Tank Flow Switch - 6

CONNECTION TO THREE-PHASE PUMP THROUGH RELAY

WARRANTYTERMS

DO NOT INSTALL ANY ELECTRICAL DEVICES BETWEEN THE BRIO AND THE PUMP (FLOAT, ETC.)

italtecnica Brio 2000 Tank Flow Switch - 8

NCREASE THE STARTING PRESSURE IF THE SYSTEM EXCEEDS 15 METRES (MAXIMUM 3.5 BAR = 35 METRES)

italtecnica Brio 2000 Tank Flow Switch - 9

ELECTRONIC EQUIPMENTTO BE DISPOSED OF INACCORDANCE WITH NA TIONALREGULA TIONS
THE MAXIMUM PRESSURE IS NOT ADJUSTABLE !!

** The maximum pressure corresponds to the pump head
DECOMMISSIONING – PERIODS OF NON-USE**

STOP DUE TO LACK OF WATER, MANUAL AUTOMATIC RESET

italtecnica Brio 2000 Tank Flow Switch - 12

Check that the pump is not blocked

REMOVE JUMPER “A” TO DISABLE THE AUTOMATIC RESET AND JUMPER “B” FOR THE 24-HOUR ANTI-BLOCK

italtecnica Brio 2000 Tank Flow Switch - 14

NOT SUITABLE FOR POOLS WITH PEOPLE IMMERSED

TECHNICAL DATA

| 115-230 V 50/60 Hz
---|---
1ph.  – 12 A max.
IP 65
10 bar max.
5 ÷ 55 °C.
-10 ÷ 50 °C  RH < 95 %
-10 ÷ 70 °C  RH < 95 %
5 ÷ 45 °C  RH < 85 %
ACTION TYPE: 1.C POLLUTION DEGREE: III OVERVOLTAGE CATEGORY: III BALL PRESSURE TEST: 85°C

ELECTRONIC EQUIPMENTTO BE DISPOSED OF INACCORDANCE WITH NA TIONALREGULA TIONS
https://www.italtecnica.com/index.php?ip=2

I TALTECNICAsrl
V .LE EUROPA31 – 35020TRIBANO (PD) ITALY
T el. 00 +39 049 9585388 –www.italtecnica.com