robern RB313 IQ Digital Lock Box User Guide

June 5, 2024
robern

IQ™
DIGITAL LOCKBOX
USER **
SET UP GUIDE**

robern RB313 IQ Digital Lock Box

Locate the key, unlock the digital lockbox and install the AA batteries (NOT INCLUDED). Check that the battery status LED is green and steady before proceeding.

robern RB313 IQ Digital Lock Box - fig

Download the Robern IQ mobile app from robern.com/IQ by clicking on App Store or Google Play and following the step-by-step instructions in the app.

https://robern.com/IQ

Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google Inc.
If you have any questions, please visit robern.com/IQ  or call Customer Service at +1 800-877-2376

Change the default access code of the digital lockbox. To set your secure access code, follow these steps:

  1. With the digital lockbox door open, press and hold the ENT button until the digital lockbox beeps.
  2. Enter any 4 to 8 digit access code, then press ENT. The digital lockbox will beep, and the status LED will flash yellow 3 times and then stay lit.robern RB313 IQ Digital Lock Box - sambly1
  3. Re-enter the same combination and then press ENT to confirm the new access code. If the combination is accepted, the digital lockbox will beep and the status LED will flash green 3 times , otherwise, the LED will flash red 3 times, and you must close the digital lockbox door and repeat the process.robern RB313 IQ Digital Lock Box - sambly2
  4. In tamper detection mode, the digital lockbox will alarm when it has been jostled or shook. If connected to Wi-Fi, an alert will be received via the smartphone app. Follow these instructions to enable tamper detection.

With the digital lockbox door open, press the “0” key for 5 seconds until the digital lockbox beeps. Tamper detection mode can be turned on or off by pressing and holding the “0” key for 5 seconds.

DEFAULT ACCESS CODE

TWO WAYS TO USE YOUR LOCKBOX: CONNECTED MODE

Use your smartphone app to receive alerts, reminders, and reports, and to unlock your digital lock box remotely. If the Wi-Fi signal is lost or out of range, the digital lock box will securely default to offline mode.

OFFLINE MODE
Offline mode means that you are not Wi-Fi connected. In this mode, the app will not connect to the digital lockbox and no data from the usage of the digital lockbox will be recorded in the app. The digital lockbox can still be opened via secure access code or physical lock and key when in offline mode. If tampered with, the digital lockbox light and the alarm will still operate.

BATTERIES REQUIRED

Four (4) AA Alkaline batteries are required to operate the digital lockbox.

  • DO NOT use rechargeable batteries
  • DO NOT mix old and new batteries
  • DO NOT mix alkaline and standard carbon-zinc batteries

ROBERN INC.
DLB

FCC STATEMENT

RF Exposure Statement
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a  minimum distance of 20cm between the radiator and any part of your body. This equipment meets the exemption from the routine evaluation limits in section 2.5 of RSS-102. It should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
FCC Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to correct the interference by one or more of the following measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Industry Canada Statement
This device contains license-exempt transmitter(s) that comply with Innovation, Science and Economic Development Canada’s license exempts RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.