PRODUCT

Thanks, For purchasing this product

Please read this manual carefully before use.

  • Model
    GTO1 Pro

  • Battery Capacity
    300mAh

  • Charging Time
    1 hour

  • Waterproof level
    5ATM

  • Operating Temperature
    O°C-60°C

  • Product Frequency
    2402-2480MHZ

  • Screen Type
    1.69″-inch Color screen

  • Charging Voltage
    5V+0.2V

  • Battery Life
    7 Day

  • Weight of Product
    41g

  • Bluetooth Version
    BLE5.1

  • Max. transmission Power Consumption
    4dBm\

KNOW THE DEVICE 

iXatch-GT01-Pro-Smart-Watch-FIG-1

Physical Button
Press the physical button

  1. Return; or
  2. Turn on the screen when the screen is off.
  3. Access the function list.

Press and hold the physical button

  1. To turn on the device in a power-off state;
  2. In the charging state, press and hold the physical button for 5s to reset the program Without clearing data.

Power On/Off
Power On
When you start charging the device, it will be turned on automatically .iXatch-GT01-Pro-Smart-Watch-FIG-2

Note: the device must be charged and activated before the first use; please always use the original charger to charge the device.

Press and hold the physical button to turn on the device.

Power Off
Shutdown path:
Setup [Power Off

Downloading and Pairing

App downloads
Download and install the “VeryFit” app on the App Store, Google Play or by scanning the QR code below.

Pairing
Turn on the VeryFit app -> Activate Bluetooth connection on your phone-> Search on the app for the device to pair with (or Scan the QR code on the device) -> Finish binding on the app (or on the device).

Screen Operations

Swipe the screen up/down

  1. TO switch among pages at the same level; or
  2. To view long text or details.

Swipe the screen left/right

To switch among pages at the same level.iXatch-GT01-Pro-Smart-Watch-
FIG-5 Click the screen

  1. 1. TO go to the sub-page;
  2. To complete the corresponding action, depending on which on-screen button is clicked.

Functions

GTO1 Pro supports features Such as multiple exercise modes, weather, watch face store, breath training, heart rate monitoring, sleep monitoring, stress level monitoring, blood Oxygen level detection, notifications, Call via Bluetooth, skin temperature monitoring, Noise monitoring. etc. For instructions and FAQS for these function5, open the app to access the user guide for answers.

Maintenance

Below are three recommendations on wearing and maintenance:

  1. Keep the device clean;
  2. Keep the device dry
  3. Do not wear the device too tight.
    • Do not use household cleaners to clean the device. Use Soap-tree cleaners instead.
    • For stains that are difficult to remove, it is recommended to sCrub with alcohol.

Waterproof performance: the device is not suitable for diving, SWimming in the sea, or sauna; it is suitable for swimming pools, showers (cold water), and swimming in shallows.

Safety

To prevent device failure, fire and explosion, never place the device or its accessories in any extremely-high-temperature or extremely-low-temperature area. To prevent device damage, accessory damage, and device failure, always protect the device against strong impact or shock. Do not disassemble or modify the device or its accessories without authorization. Any device failure should be referred to our after-sales service personnel.

The device meets the EU ROHS criterion. Please refer to IEC 62321, EU ROHS Directive 2011/65/EU, and the revised directive.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two Conditions

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Changes or modifications not expressly approved by the party responsible for compliance could avoid the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to art 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.

If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

CAUTION
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO 1O THE INSTRUCTIONS

Old electrical appliances must not be disposed of together with the residual waste, but have to be disposed of separately. The disposal at the communal collecting point via private persons is for free. The owner of old appliances is responsible to bring the appliances to these collecting points or to similar collection points. With this little personal effort, you contribute to recycling valuable raw materials and the treatment of toxic substances.

If you experience discomfort or skin irritation when wearing your smartwatch, then we recommend you try cleaning your device. Sometimes residue or foreign materials build up around your device and may aggravate your skin. It’s also possible that you are not wearing the watch correctly. We recommend making sure to clean and adjust your watch regularly for a more comfortable fit.

Caution:
If you experience skin irritation when wearing your watch, please refrain from wearing, it and wait two to three days to see if your symptoms ease. If symptoms persist or worsen, please consult a physician. If you have eczema, allergies or asthma, you may be more likely to experience skin irritation or allergy from a wearable device.

CAUTION
Risk of explosion if the battery is replaced by incorrect type disposal of a battery into fire or a hot oven, or mechanically crushing or Cutting of a battery, that can
result in an explosion; leaving a battery in an extremely high-temperature Surrounding environment that Can reşult in an explosion or the leakage of flammable liquid or gas; a battery subjected to the extremely low air pressure that may resúlt in an explosion or the leakage of flammable liquid or gas.