Sequence Power-PRO1018A
Important Safety Instruction and symbol description
-
Read these instructions.
-
Keep this user manual.
-
Pay attention to all the notice.
-
Comply with these instructions.
-
Warning:to reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
Equipment should not be exposed to water or water splash, and equipment shall not be placed for a class of items such as vases filled with liquid. -
Suggested use dry cloth to clean.
-
Install the equipment according to User’s Manual.
-
Do not install the equipment closed to the heat source, such as radiator, heat regulating device, furnace etc.
-
This equipment should be connected to a socket by protective grounding.
-
Protect the wire from being trampled or extruded, especially the plug, socket and the connector of it.
-
Must be used nominal voltage of the power supply same as the one written on the top cover.
If damage caused by improper use of voltage, it will be served as a paid service. -
For link control please refer to Page 4 of this User’s Manual.
Notice for important information
There is risk for electric shock as there are uninsulated parts inside
the machine. It is not allowed to open the cover of the machine except the
professional for maintenance.
Foreword
Thank you for purchasing our products. Please read this manual in detail
before use, it will give you the use instructions and help for the normal
working, avoid the wrong operation to make unnecessary abnormal problems.
Unpacking
Please unpack and inspect your amplifier for any damage that may have occurred
during transit. Confirm the preset voltage of the Sequence Power matches your
local voltage rating ( Please refer to the print on the rear panel for
detailed information). e also recommend that you save all packing materials
so you will have them when need to return the Sequence Power.
Important safety precautions
Our products has already taken the safe requirement in to consideration and
all the finished products have been tested under the requirement of the
government before sale. Due to the inner dangerous high voltage and
electricity, we strongly recommend you read all instructions, warnings and
cautions contained in this manual. It will increase the chance of getting
shock by the electricity if the product falls down, recess in the appearance,
soaked or there were some parts loose internal. If there are problems above,
please turn off power immediately and send the defective units to local
distributor for service.
Product features
- PRO1018A adopted SMPS power supply, available for universal voltage 100-240V.
- Circuit breaker with over-current and short circuit protection.
- Multipile link to 16, 24, 32 outputs sequence control.
- Universal socket, compatible with different style of the power plug.
Front panel introduction
Power cable connection
Note :The machine comes with its own power cable+ power plug, which is
wired internally. Users do not need additional wiring!
Front Panel Function Introduction
Attention: must use the high-power power line plug or socket, to prevent the power is too small to cause ignition and other safety hazards!
Rear panel introduction Rear plate
overload circuit breaker, when the total current of the sequencer continues to
exceed 40A, it will automatically jump off and enter overload protection
state, after the load is reduced Need to re-press the button on the circuit
breaker to return to work!
Notes for online control
-
The RJ45 Network cable must be connected in the power outage state,(shut off the main switch) and all slave machines(SEQUENCE) switch must be off, waiting for the command control of the host machine.
Slave machine: This switch is kept off, waiting for the instructions of the host machine. -
Sequence on/off state is controlled by sequence switch, Turn on: “ON” from 1 to 8 (from left to right) Turn off: “OFF” from 8 to l(from right to left)
-
In multiple online communication, after opening the sequence control switch of the first machine, it will continue to open to the last one in the current on line in order. and then Close instead,start with the last one and close to the first one.
-
In the online working state, do not unplug the power line or on line line. Otherwise it will cause the interruption of the online signal and online abnormal.
-
Please use standard network cable to connect; If you make your own network cable, make sure that the network cable connection method is straight.Namely the crystal head at both ends, the color of the (1), (2)and (3) line in the figure below must be the same at both ends,When using the online function of the computer, the length of the network cable is recommended not to exceed 15 meters. If the on line cable is too long, it will be dangerousAffects the quality of communication.
In-process code
Central control transfer protocol setting
- Device number: input range 01~08, device number 01 is the head machine, directly connected to the central control system;The following figure shows the example of central control system instruction of device no. 01, other instruction codes and details of central control system instruction of other device No. 01.Please refer to the timing central control system application code and its documentation.
Function | Instructions first | Device number | Instruction tail |
---|---|---|---|
Sequential on | AC | 16 | 1 |
Sequential off | AC | 16 | 1 |
Sequential on/off | AC | 15 | 1 |
Channel 1 on | AC | 11 | 1 |
Channel 1 off | AC | 11 | 1 |
Channel 2 on | AC | 11 | 1 |
Channel 2 off | AC | 11 | 1 |
Channel 3 on | AC | 11 | 1 |
Channel 3 off | AC | 11 | 1 |
Channel 4 on | AC | 11 | 1 |
Channel 4 off | AC | 11 | 1 |
Channel 5 on | AC | 11 | 1 |
Channel 5 off | AC | 11 | 1 |
Channel 6 on | AC | 11 | 1 |
Channel 6 off | AC | 11 | 1 |
Channel 7 on | AC | 11 | 1 |
Channel 7 off | AC | 11 | 1 |
Channel 8 on | AC | 11 | 1 |
Channel 8 off | AC | 11 | 1 |
Example of device number “01” in the table
http://www.saeaudio.com/manual/PS8.rar
**** Baud rate: 115200
Data bit: 8 bits
Stop bit: 1 bit
Parity check: None
Specifications
Limit power
Input power connection
Power switch and over current protection
Sequence controlled output channel quantity
Without sequence controlled output channel quantity
Max. output current per channel
Sequence control mode
Sequence interval
Sequence independent switch function
Power cable
Working voltage
Product Dimension ( mm )
Packaging Dimension ( mm )
G.W| <-100-240V-/40A
Power lead head fixed, internal wiring
The 40A press recovery circuit breaker has overcurrent and short-circuit
protection.
8 pcs compatible power sockets(rear panel)
1 pc compatible power socket ( Front panel )
Audio equipment loading<20A, linear pure resistance loading <10A ( Cannot be
used in stage lighting equipments)
Power control and online control
1.Ss/step
Press “Disconnection”can turn off corresponding channel
2.Smm2
Power cable
100V~240V /50~60Hz ±10%
483xl 78×44.5
525x265x110
3.5kg
---|---
Product dimension(mm)
Suitable model:PRO1018A
The manufacturer reserves the rights to make changes in specification without
prior notice.
The final specification is subject to the user’s manual.
Manufacturer:Sae Audio Co.,LTD.
Sae reserves the right to make changes in specifications
and products without prior notice.