TERRABLOOM ECMF-250 10 Inch EC Inline Duct Fan
GREETINGS FROM TERRABLOOM
Thank you for choosing Terra Bloom fans for your ventilation needs. This ECMF
series fan is built with a new generation EC motor which creates powerful,
high-pressure airflow while saving energy. A wide range of compatible speed
controllers allow you to adjust the output of this unit to fit your
application. We do our best to ensure customer satisfaction. If you have any
suggestions, questions or comments, please contact us directly at support
@terra-bloom.com or through our contact form at www
.terra-bloom.com. We are located in sunny
Southern California and reply to your messages Monday-Friday, 9am-5pm PST.
SAFETY WARNING
- This ventilation fan can be used by adults and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- To avoid the risk of electrical shock, or injury to persons, always make sure that the fan is unplugged from the electrical outlet before relocating, servicing, or cleaning the product.
- Never touch moving parts when the fan is on or the impeller is moving.
- If installed without ducting, use a protective grille and install the fan away from the reach of children and pets.
- The fan contains no user-serviceable parts inside. Refer to the manufacturer for service.
- Do not pull the power cord too hard or hold the fan by the power cord. If the power cord is damaged or frayed it must be replaced by the manufacturer or a qualified service person.
- Keep this instructions manual for future reference.
PRODUCT CONTENTS
FAN APPLICATIONS
Terra Bloom EC fans generate powerful directional airflow required for a
variety of commercial and residential applications. Our fans can be used in,
but not limited to:
- Intake, exhaust, and over-canopy ventilation in indoor plant cultivation.
- Air filtration, VOC and airborne pathogen control (when used with a matching carbon filter)
- Indoor temperature and humidity management in rooms, attics, crawl spaces
- Boosting airflow in AC and heating ducts to reach remote rooms
- Drying applications
- Creating negative pressure environments
- Wind simulation
- Art installations
- Any application requiring strong directional air movement
OPERATING ENVIRONMENT REQUIREMENTS
- This fan is intended and rated for indoor use only.
- Operating temperature range: -5°F – 140°F (-20°C – 60°C). Humidity range: 0- 90%.
- Not suitable for applications in close proximity to open flame (wood or gas burning) furnaces. Temperatures over 140° F can cause permanent damage to electronic components.
- Not suitable for environments with flammable or hazardous substances, explosive gases or chemical dust.
- In environments with high dust or debris content, use a pre-filter to prevent dust, grease and other foreign substances from building up on the fan blades. Debris buildup leads to mechanical damage, increased vibration and noise.
INSTALLATION
- Inspect fan for shipping damage before installation. Ensure that the fan blade rotates freely without touching the housing.
- Securely attach the fan to a hard surface using the pre-installed mounting bracket and screws designed for the surface type in your application.
- Do not install on hollow drywall. Mount to hard surfaces (i.e .. wood, concrete, metal).
- If used with securely installed carbon filters, it is acceptable to install the fan on top of the filter’s duct collar. Secure the connection with a duct clamp.
- This fan can be installed in all mounting positions.
- In the hanging installation, use adjustable ratchet ropes or heavy-duty zip ties to suspend the fan from a rigid surface such as the ceiling, beam, joist or steel frame of a grow tent.
APPLICATION TIPS
-
The ducting has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
-
A duct of matching size with the fan inlet and exhaust is recommended for best performance. Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create an air-tight path and to minimize building heat loss and gain and reduce the potential for condensation. Place/wrap insulation around duct and/or fan to in order to minimize possible condensation buildup within the duct, as well as minimize building heat loss and gain.
-
When installed vertically and connected to the outdoors via a duct, use a
vent cap with a loaded damper to protect the fan and duct from the outdoor elements. -
Install the fan at least 6ft above the floor to keep it out of reach of children and pets. For added safety use metal grills/guards to keep fan’s moving parts from the reach of children and pets.
-
After installation, perform a test run to confirm that the fan operates as intended. A speed controller must be connected to the fan before power up.
-
Once powered on, the fan blade should rotate freely and accelerate gradually.
-
If excessive noise is present, verify that there are no foreign objects (duct pieces, screws, etc.) touching the fan blade. Secure installation to a hard and stable surface is key to avoiding vibration and excessive noise.
-
Do not place a duct bend directly before or after the fan. The length of the unobstructed straight duct before and after the fan should be equal to at least 2.Sx the diameter of the fan. For example, a 6″ fan should have at least 2. Sx6″=15″ of straight duct before and after the fan.
FAN OPERATION WITH SPEED CONTROLLER
- You must use a speed controller in order to operate this fan. The fan will not start if it is not connected to a compatible speed controller.
- Locate the speed controller port under a screw-on plastic dust cap on the side (ECMF models) or top (ECMF-S models) of the fan.
- For your convenience, with your purchase we include two speed controllers in set with the fan. Only one speed controller can be used with the fan at a time. Multiple speed controllers cannot be connected simultaneously.
- Controller 1 – 8 speed digital speed controller. Each press of a button on the controller increases the speed by 1 level or 12.5%. Speed level 1 = 12.5% of maximum speed, Level 2 = 25%, Level 3 = 37.5%, Level 4 = 50%, Level 5 = 62.5%, Level 6 = 75%, Level 7 = 87.5%, Level 8 = 100% (maximum speed).
- Controller 2 – Granular variable speed controller. Variable dial speed controller is a potentiometer type speed controller which allows for granular speed adjustment. To increase the fan’s speed turn the dial clockwise, to reduce the speed, turn the dial counter-clockwise
- Insert each speed controller wire jack fully into the connection port until it clicks into position. Secure in place with a plastic locking nut located on the speed controller wire.
OPTIONAL SPEED CONTROLLERS
- Terra Bloom offers a programmable thermostat speed controller with a temperature probe (Model: SC-ECMF) and a wireless remote speed controller (Model: ECMF-WR).
- PWM controllers (Arduino, Raspberry Pl, etc) use the frequency range of 15-32kHz and voltage range of 10-12V.
- If used with a third party speed controller, use the provided TRRS 3.5mm connection wire or a DIV speed controller wire with pin outputs to connect the fan with the controller
- Refer to the illustration below for a description of pin outputs on the DIV speed controller wire.
DIV SPEED CONTROLLER WIRING DIAGRAM
DIV SPEED CONTROLLER WIRE
NOTE ON FAN OUTPUT AND STATIC PRESSURE
-
The CFM rate stated on the fan and in the tables below is a “nominal” airflow rate and is applicable only when no additional equipment is attached to the fan.
-
When you attach any equipment to the fan (ducts, vent caps, filters, splitters, elbows, etc.) you are introducing static pressure, an obstacle in the path of the airflow. This will cause the final amount of airflow delivered by the fan to be lower than the nominal airflow.
-
Each duct fan has a maximum pressure rating which equals to the maximum static pressure it can counteract in order to move a certain volume of air.
-
To achieve optimal results, you must take static pressure into consideration when choosing the inline duct fan to use in your application.
-
A pressure drop is the amount of static pressure introduced by a filter or any equipment attached to the fan.
-
To find the precise value of airflow produced by a fan in a particular application, refer to our web-site for the pressure curve of your fan model. The pressure curve shows the CFM output of the fan at different pressure levels. Once you calculate the amount of pressure created by all of the equipment attached
to the fan, locate that pressure level on the pressure curve to pinpoint the corresponding CFM output. -
If the pressure drop and/or pressure curves are not available, assume that the carbon filter will reduce the amount of airflow by 30-40% from the nominal airflow rate stated on the fan. The thicker the carbon bed, the higher the pressure drop. When using ducts to connect the fan and filter, please factor an additional airflow reduction of 3% (smooth metal duct) to 7% (flexible ribbed duct) for every 25ft of duct. 90° turns in ducting cause an additional 1%-4%reduction in airflow.
FAN SPECIFICATIONS. ECMF MODELS
DIMENSIONS IN MM. ECMF MODELS
FAN SPECIFICATIONS. ECMF-S MODELS
DIMENSIONS IN MM. ECMF-S MODELS
FAN MAINTENANCE
- Use a damp cloth to remove dust and any debris build up from fan components every 6-12 months
- To avoid mechanical damage, do not apply pressure to the fan blades.
WARRANTY
ECM F series fans are covered by a 2 year warranty from the date of purchase against any defects in workmanship or materials. Under warranty, the fan will be either replaced or repaired and must be accompanied by proof of purchase. The warranty doesn’t apply to any damage caused by excess heat or humidity, misuse in harsh industrial environments, physical damage or normal wear and tear of the unit.
TERRABLOOM ACCESSORIES FOR USE WITH ECMF FANS
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>