Function
This double socket outlet with built-in USB charger charges the batteries from mobile devices such as mobile phones, MP3 players, tablets etc. Up to two devices can be simultaneously charged using both USB ports. The total output current of the charger is 2,400mA at 5V DC (+/- 5%).
This double socket outlet is equipped with a side grounding contact and increased contact protection according to VDE0620. The maximum permissible voltage is 250V 50Hz. 16A. Only install and use this IP20 protected product in protected locations with an ambient temperature between + 5°C and + 35°C. Avoid the influence of moisture, dust, sun or other heat radiation. For prolonged use, the housing of this product may become warm. This is normal.
HAZARD WARNING
- Operate the device only in indoor areas. Avoid the influence of moisture, dust, sun or other heat radiation.
- The socket outlet is part of the building installation. The relevant standards and directives of the country must be observed during planning and construction. The operation of the device is permissible only on the 230V / 50 Hz alternating current network. Work on the 230V mains may only be carried out by a certified electrician qualified in your country. The applicable accident prevention regulations must be observed.
- To avoid an electric shock on the device, please disconnect the mains voltage to the device (switch off the circuit breaker). Failure to comply with the installation instructions may cause fire or other hazards.
- The installation may only be carried out in commercially available flush-mounted wall-boxes (installation boxes), with a minimum depth of 40mm, in accordance with DIN 49073-1.
- When connecting the device terminals, observe the type of cabling which are permissible for this purpose.
- Pay close attention to the wiring diagram!
Mandatory information in accordance with the equipment safety standard
Note! Only to be installed by persons with relevant electrical qualifications and experience)
Improper installation will result in risk to your own life and risk to the life of persons using the electrical installation. With an improper installation, you risk serious material damages, for example fire. You are personally liable for personal injury and material damages.
Please contact a qualified electrical engineer!
Specialist skills required for installation
In particular, the following special knowledge is required for the installation:
- The applicable “5 Safety Rules”: disconnect; protect against switching on; verifying mains power disconnect; earthing and short-circuiting; covering adjacent current-carrying components or making them inaccessible;
- Selection of suitable tools, measuring equipment and – if necessary -personal protection equipment;
- Evaluation of measurement results;
- Selection of the electrical installation material to ensure compliance with the shut-down conditions;
- IP-Protection classes;
- Installation of electrical installation material;
- Identification of the supply grid type (TN system, IT system, TT system) and the resulting connection conditions (conventional protective multiple earthing, safety earthing, additional measures required etc.).
Mounting
Step 1: Switch off the appropriate circuit breaker.
Step 2: If necessary, remove the existing power outlet.
Step 3: Loosen both central screws (F) and remove the cover (C) from the
base plate (B).
Step 4: Connect the ground wire to terminal®.
Step 5: Connect the phase conductor to terminal (L).
Step 6: Connect the neutral conductor to terminal (N).
Step 7: If your flush-mount wall-box (A) is equipped with screws, fasten
the base plate (B) to the flush-mount wall-box using two screws (not
supplied). In case your flush-mount wall-box (A) is not equipped with screws,
fasten the base plate (B) directly to the wall using screw holes (E) and four
screws (not supplied).
Step 8: Carefully mount the cover (C) on the base plate (B) and fasten
both central screws (F).
Step 9: Turn the appropriate circuit breaker back on again.
Step 10: Enjoy your new socket-outlet with built-in USB charger.
Maintenance and cleaning
The socket-outlet is maintenance-free. Any repairs should only be carried out by a qualified electrician. Clean the unit with a soft, clean, dry, lint-free cloth only. Please do not use solvent-based cleaning agents. The plastic housing could be affected by this. Do not use wet cloths or sponges to clean the socket-outlet.
Disposal
RoHS/WEEE Compliance Statement (Recycling Instructions)
European Directive 2012/19/EU requires that equipment bearing the trashcan symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.
Technical Specifications USB Charger
- Input voltage 220 – 250V— 50Hz
- Input current Max. 0,5A
- Output voltage 4,75 – 5,25V=
- Output current 0,01 – 2,4A
- Output power 12 Watt Energy Efficiency 130%
- Power loss (Standby consumption) s50mW
Documentation
© Smarter Living BV, Netherlands. All rights reserved. We accept no liability for technical or printing errors and their consequences. All trademarks and property rights are acknowledged. Changes in the sense of technical progress may be made without prior notice.
EU Declaration of Conformity
We, the manufacturer / importer,
Smarter Living BV
Wilgenbos 20
3311 JX Dordrecht
The Netherlands
declare that the product:
Description: 2USB easyCharge DUO 12W
Model number: JP-9001 F
Is in compliance with the essential requirements and other relevant provisions
of the following directives:
RoHS Directive (2011/65/EU)
EMC Directive (2014/30/EU)
Low Voltage Directive (2014/35/EU)
ErP Directive (2009/125/EC)
This product is in compliance with the following standards:
IEC 60844-1 (incl. DE, NL, FI, NO, SE deviations)
IEC 60950-1
IEC 61558-1
IEC 61558-2-16
EN 55032 (class-B)
EN 55024 EN 60669-2-1 (clause 26)
Intended use: Indoor
Dordrecht, 02-11-2017