MAC500S
**Multi Air Cleaner
User Guide
**
# Chemicalfreeworld
Environmentally Friendly
Air purification and Surface Disinfection Solutions for The Future
Description
MAC500s produce UV-C light under controlled conditions. Different UV-C
wavelength has different properties. The MAC500s uses two wavelengths. One is
a powerful sterilizer when it is in direct contact with pathogens and the
other wavelength uses the available oxygen (O2) to naturally produce a low
level of ozone (O3). The low level of ozone recreates the fresh air from
outside in nature inside your home or office.
This method is called photolytic oxidation and JIMCO A/S has won the EU
environmental Award for Developing a Cleaner Technology.
The purpose of the MAC500s is to purify the air you breathe.
- Read the user instructions carefully before using the unit.
- Keep the user instructions for future reference.
- Connect the instrument to a suitable plug socket.
- Place the machine on a solid surface. Profitable high for the best effect
- For wall mounting, you can attach the appliance by means of the punched mounting holes
- Never immerse the appliance in water
Intended use
The MAC500 is intended to be used 24 hours a day. The recommended room size is
60 m3 (24 m2 with a ceiling height of 2,5 m). The unit should not be operated
while situated on the floor but should be placed as high as possible for
maximum efficiency.
The unit must not be operated without cover.
When more units are placed in a room they must be placed as far from each
other as possible to get an even distribution of the area they cover.
Function
Photolytic oxidation makes cold incineration with airborne pathogens and
organic particles such as fungal spores, viruses, bacteria, yeast, ethylene
gasses, nicotine, etc. The process is environmentally friendly and the cold
incineration will reduce the airborne pathogens and organic particles
significantly.
The MAC500s can be operated in temperatures between 4-45 degrees Celsius. The
unit can be used in refrigerators to reduce ethylene gasses, bacteria, and
fungal spores, which will extend the shelf life of food, fruit, and
vegetables.
The MAC500s will effectively reduce odor from rooms deposited in walls,
carpets, textiles, furniture, etc.
WARNING!!!
Before opening the appliance, it must be switched off, and unplugged from the
socket.
When the device is open, there is a risk of radiation from the UV-C light
- This can lead to painful corneal inflammation (conjunctivitis)
Lifetime of the lamps
The lifetime of the JIMCO special lamp is 8,000 operating hours. When the lamp
has been used for 8,000 operating hours, the efficiency of the lamp will be
reduced, which means if the smell is not reduced as usual then the lamp should
be replaced.
8,000 operating hours, equals to approximately a year of operation (21.9 hours
per day). If the effect of the device drops before the end of 8,000 operating
hours, you should check, if the JIMCO Special lamp is dirty with e.g. dust
particles.
Is this the case? Then follow the maintenance instructions.
Maintenance
To maintain the optimal performance of the MAC500, we recommend – for regular
use – cleaning the lamp and fan about every 3 months. When it is used in
heavily soiled/dusty rooms, this should be done more often.
Cleaning the appliance:
Turn off the appliance and then unplug the appliance from the socket Clean the
outside of the appliance with a damp cloth, and use a little detergent if
necessary (Follow the instructions of the detergent).
Clean the lamp and fan with a clean and soft cloth, and use a little ethyl
alcohol if necessary.
Note the date of cleaning.
Make sure the lamp is clean. If any part of the lamp is covered, then that piece of the lamp will not work anymore.
Warranty Regulations
On the MAC500, JIMCO A/S provides a 24-month warranty. The guarantee period is
12 months. The warranty is calculated from the date of sale from your JIMCO
dealer. To provide this, a receipt must be kept. Within the stated warranty
period, JIMCO A/S will cover, without charge, every defect that is subject to
material or manufacturing defects and, at your option, provides warranty
repair or replacement of the MAC 500.
A prerequisite for the guaranteed benefit is that the appliance is used
according to its purpose and in accordance with the operating instructions.
Excluded from the warranty are damages caused by improper use, wear, or
interference on the part of the owner or third parties. The warranty does not
cover consumables – For example lamps – Or wearing objects such as a fan and
lacking which only negatively affects the value or usefulness of the MAC 500.
Technical Data
UV lamp 1×8 w
Voltage 120V 50/60Hz
Power consumption 23 w
Room area 60 m3| Operating hours
Length
Height
Width| 8000 timer
310 mm
90 mm
90mm
---|---|---
Operation
- Switch the appliance on and off with the On / Off switch(1) The red lamp lights to indicate that the appliance is now switched on
- The pushbutton (2) can switch between high and low speed. The red light on the button lights when the fan is running at high speed. The appliance always starts at High speed when switched on.
- Pressing the Timer button (3) sets the unit to Timer mode. When the Timer button is pressed, the fan will run at the current speed for 8 hours, then switch speeds for16 hours. This cycle continues until the timer button (3) impressed again or the unit is switched off. The red light on the button indicates that the unit is in Timer mode -When there are 500 operating hours left, the On / Off lamp will start to flash. When the appliance has been in operation for more than 8000 hours, all 3 red lights start flashing and an acoustic signal is heard around every 30 minutes. The lamp must now be replaced.
- When the lamp is replaced Reset the Timer by holding down the Timer button (3) and the Fan button (2) for more than 5 seconds. 5 quick beeps are heard, and the unit is ready for use again.
Lamp change:
Step: 1
Disconnect the power to the MAC500 by unplugging (position 2) from the wall socket
Step: 2 Remove the four screws (position 3) and remove the cover (position 4)
Step: 3
Lift the lamp (position 5) out of lamp clip A (position 6) and lamp clip B (position 7)
Step: 4
Pull the lamp (position 5) out of the socket (position 8)
Step: 5
Insert the new lamp (position 11) into the socket (position 8)
Step: 6
Push the lamp (position 11) down into lamp clip B (position 7) and lamp clip A (position 6)
Step: 7
Attach the lid (position 4) and install the four screws (position 3)
STATEMENT OF COMPLIANCE
The undersigned, who represents the manufacturer mentioned below
Manufacturer: | Jimco A\S |
---|---|
Address. | Miolbvvet 7 — DK-5900 Rudkobing |
or who represents the manufacturer’s authorized representative within the EU
Authorized representative:
Address:
Declare that
Product identification: MAC500S
is manufactured in compliance with the following EU directives:
Reference No. | Title |
---|
2014/35/EU
2014/30/F.U| Low Voltage Directive(LVD)
Electromagnetic Compatibility (EMC) Directive
And the standards and/or technical specifications mentioned below.
Year when CE label was affixed; 1999
Identification of signet flintily Larsen
No. | Version | Title | parts |
---|
N60204-1
EN IEC 55014-1| 2| Machinery Safety — Electrical material on machinery
Electromagnetic compatibility- Requirements for household appliances and
similar products| Part 1: Emission
Other standards al d/or technical specifications:
No. | Version | Title | parts |
---|---|---|---|
Other technical solutions, where detailed information is included in the technical documentation or the technical dossier for the construction.
Questions and Contact
Producer: Jimco A/S +45 6251 5456
www.jimco.dk
Lamp replacement:
| | |
---|---|---|---
| | |
Mjolbyvej 7
• DK-5900 Rudkobing
• Denmark
•1Tel: +45 62 51 54 56
• E-mail:jimco@jimco.dk
• Web:www.jimco.dk
JIMCO A/S – EST. 1992
• CVRIVAT No. DK 2500 0374
Documents / Resources
|
JIMCO MAC500S Multi Air
Cleaner
[pdf] User Guide
MAC500S, Multi Air Cleaner, Air Cleaner
---|---
|
JIMCO MAC500s Multi Air
Cleaner
[pdf] User Guide
MAC500s Multi Air Cleaner, MAC500s, Multi, MAC500s Air Cleaner, MAC500s
Cleaner
References
- JIMCO Air Treatment Company | High Quality Air Purifiers Since 1992
- JIMCO Air Treatment Company | High Quality Air Purifiers Since 1992
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>