AMTROL WH Series Indirect Fired Water Heaters User Manual
- June 1, 2024
- AMTROL
Table of Contents
AMTROL WH Series Indirect Fired Water Heaters
NOTE: A properly sized thermal expansion tank is required and should be
installed by the product installation manual.
NOTE: The thermostat is adjusted to 120°F when shipped from the factory.
NOTE : Inspect for shipping damage and notify the freight carrier or store where purchased immediately if the damage is present. To avoid the risk of personal injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.
THIS IS THE SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU TO POTENTIAL PERSONAL INJURY AND OTHER HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO REDUCE THE RISK OF PERSONAL INJURY AS WELL AS PROPERTY DAMAGE.
Warning
READ CAREFULLY THE PRODUCT INSTALLATION & OPERATION INSTRUCTIONS. FAILURE TO
FOLLOW THE INSTRUCTIONS AND WARNINGS IN THE MANUAL MAY RESULT IN SERIOUS OR
FATAL INJURY AND/OR PROPERTY DAMAGE AND WILL VOID THE PRODUCT WARRANTY. THIS
PRODUCT MUST BE INSTALLED BY A QUALIFIED PROFESSIONAL. FOLLOW ALL APPLICABLE
LOCAL AND STATE CODES AND REGULATIONS, IN THE ABSENCE OF SUCH CODES, FOLLOW
THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND NATIONAL ELECTRIC CODE,
AS APPLICABLE.
Warning
This Product, like most Products under pressure, may over time corrode, weaken
and burst or explode, causing serious or fatal injury, leaking or flooding
and/or property damage. To minimize risk, a licensed professional must install
and periodically inspect and service the Product. A drip pan connected to an
adequate drain must be installed if leaking or flooding could cause property
damage. Do not locate in an area where leaking could cause property damage to
the area adjacent to the appliance or the lower floors of the structure.
Warning
CALIFORNIA PROPOSITION 65 WARNING! This product contains a chemical known
by the State of California to cause cancer and to cause birth defects or other
reproductive harm. (California Installer/Contractor – California law requires
that this notice be given to the consumer/end-user of this product.) For more
information: www.amtrol.com/prop65.html
relief valve must be installed to prevent pressure over local code
requirements or the maximum working pressure designated in the Product Manual,
whichever is less. At least once every 3 years or if the discharge is present,
a licensed contractor should inspect the temperature and pressure relief valve
and replace them if corrosion is evident or the valve does not function.
Warning
FAILURE TO INSPECT THIS VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE
OR PRESSURE BUILD-UP WHICH CAN RESULT IN PRODUCT FAILURE, SERIOUS INJURY OR
DEATH AND/OR SEVERE PROPERTY DAMAGE AND VOID THE PRODUCT WARRANTY.
Warning
Chlorine Aggressive Water: The water quality can significantly influence
the life of this Product. You should test for corrosive elements, acidity,
total solids and other relevant contaminants, including chlorine and treat
your water appropriately to ensure satisfactory performance and prevent
premature failure.
Warning
EXPLOSION HAZARD. The pressure of the heat transfer medium must be limited
to a maximum of 30 psig by an approved safety or relief valve on your boiler.
The water heater pressure must be limited to 150 psig maximum by the
installation of a temperature and pressure relief valve (included). The relief
tube must be plumbed to a suitable drain per code. No reducing coupling or
other restriction may be placed in this line. The heat transfer medium must be
water or other nontoxic fluid having a toxicity rating or class of 1, as
listed in Clinical Toxicology of Commercial Products, 5th edition. The
pressure of the heat transfer medium must be limited to 30 PSIG by an approved
safety or relief valve. Do not expose the Product to freezing temperatures or
temperatures over the maximum rated operating temperature.
Warning
SCALDING HAZARD. If the water temperature is over 120°F, household members can
suffer serious or fatal scalding and painful and permanent injury.
- The Consumer Products Safety Commission recommends an initial setting of 120°F but advises that a slower response time of infants, aged, disabled and other persons increases the scalding hazard and may require lower settings.
- Always check the water temperature before use, including washing, bathing or showering.
- Temperature-limiting valves are available from your plumbing supplier.
- A check valve must be installed in the boiler return line to prevent gravity flow through the heat exchanger. This can cause overheating and result in serious or fatal scalding.
Warning
SCALDING HAZARD. If the thermostat is not working properly or if this
product is not installed manually, the water temperature can reach excessive
levels that may cause serious or fatal scalding. After installation and any
servicing of the unit, verify that the thermostat is working and firmly
inserted in the thermostat well by following the thermostat testing
instructions in the manual.
Caution
Failure to use the correct replacement parts may make your product unsafe. In
limited circumstances, space heating can be lost in the home with the unit
utilizing priority mode. Any demand for space heating is postponed until the
water heater has reached its set temperature. This delay in supplying the
space heating zones is usually not noticed by the inhabitants of the living
spaces.
However, in the event of certain malfunctions such as circulator or thermostat failure, space heating could be delayed indefinitely. If undetected and uncorrected, freezing damage to piping could result. If a steel hydropneumatic tank is in place, replace it with a properly sized diaphragm expansion tank. Otherwise, significant heat transfer problems can occur by causing air to be trapped in the heat exchanger. If the boiler system has a diaphragm expansion tank and the boiler temperatures are being changed, resize the expansion tank. If installed on the city water supply, a properly sized thermal expansion tank is required with the water heater and should be installed as outlined in the product installation manual. Contact your water supplier or local plumbing inspector for additional information.
Prevent pressure build-up in any existing internal tankless coil. Do not plug incoming or outgoing tappings in the internal tankless coil plate. Leave the coil in the boiler and leave system connections open to prevent pressure build-up. Electrocution hazard. The water heater must be electrically grounded by local codes or, in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70. The electrical supply must come from the boiler side of the boiler’s emergency shut-off switch to prevent unsafe boiler operation. If not installed by the boiler manufacturer, install a low water cut-off or pressure-reducing valve on your boiler so that leaking will not result in a dry boiler which if the boiler continues to fire, will cause an explosion hazard.
This unit must be installed as a separate heating zone. Do not connect this unit to an existing heating zone or feed boiler water directly through the coil as dangerous overheating will result. Do not drain this appliance before shutting off the supply valve and opening the relief valve or another downstream fixture, as it will damage this unit. A vacuum breaker should be installed to avoid damaging the liner. Damage to the unit and leakage can occur if a vacuum breaker is not installed. As in all plumbing products and water storage vessels, bacteria can grow in this Product, especially during times of non-use. Consult your local plumbing professional regarding any steps you may wish to take to safely disinfect your home’s plumbing system.
USE GLYCOL ONLY WITH DOUBLE-WALLED HEAT EXCHANGER MODELS
Glycol is a poisonous substance. To avoid seepage or leakage of glycol to
surfaces where humans or animals can ingest it, use glycol only in double-
walled units, so that any leaks will most likely be released to the
atmosphere. However, a leak to a surface area may still occur, so any use of
glycol must be monitored closely and humans and animals should be protected
from contact with the unit. Do not connect the water heater’s domestic supply
to the baseboard or other space heating units or elements. Any contaminants in
the baseboard units will contaminate the potable water in the water heater and
also adversely affect its performance. Do not drill, puncture or otherwise
penetrate the steel outer tank shell. Do not screw pipe hangers or other
hardware into the exterior of the tank. PLEASE READ THE FOLLOWING INSTRUCTIONS
CAREFULLY IMPORTANT GENERAL SAFETY INFORMATION – ADDITIONAL SPECIFIC SAFETY
ALERTS APPEAR IN THE FOLLOWING INSTRUCTIONS.
Pre-Installation
- THIS PRODUCT MUST BE INSTALLED AND MAINTAINED BY A LICENSED PROFESSIONAL PLUMBER, OR ELECTRICIAN, AS APPLICABLE. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND STATE CODES INCLUDING MA CMR 248 OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NATIONAL PLUMBING CODE AND THE NATIONAL ELECTRIC CODE.
- DRIP PAN AND DRAIN: This appliance should not be installed in an area where leakage of the tank or connections can result in damage to the area adjacent to the appliance or the lower floors of the structure. When such locations cannot be avoided, a suitable drain pan, adequately drained and kept clear, must be installed under the appliance.
- CAUTION: Determine whether your water is corrosive or acidic, and that there are no suspended solids, toxic or other substances or abnormally high chlorine levels in the water that could damage or affect the water heater or the rest of your plumbing system.
- Wiring Options. Select either a Non-Priority or Priority System: Two options are available when wiring the controls of the water heater in the space heating system (boiler and distribution elements).
Non-Priority System – The controls of the water heater must be wired as a
separate heating zone with a standard zone valve or a separate circulator
dedicated to the water heater “zone”.
NOTICE: In this non-priority option, the water heater will be supplied
just as another zone. This means that if all space heating zones call for hot
boiler water at the same time, the water heater may not be supplied with
enough hot boiler water to “recover” adequately. The delivery of domestic hot
water will be diminished. In many, but not all cases, this is not a problem
because the routine oversizing of boiler output is adequate for both loads.
Priority System – Under this wiring option the water heater will be supplied before space heating. In limited circumstances, space heating can be lost in the home in this priority mode. Any demand for space heating is postponed until the water heater has reached its set temperature. This delay in supplying the space heating zones is usually not noticed by the inhabitants of the living spaces. However, in the event of certain malfunctions such as circulator or thermostat failure, space heating could be delayed indefinitely. If undetected and uncorrected, freezing damage to piping could result.
Select Circulator versus Zone Valve
The flow of hot boiler water to the water heater can be controlled with either
a motorized zone valve or a circulator.
- Separate circulator. The recommended way to provide adequate flow through the water heater heat exchanger is to use a separate dedicated circulator. This option may be used even though the heating system utilizes zone valves.
- Zone valve. If a zone valve is to be used, a flow rate of 3 to 5 gpm with all zones in use is required. A full-port zone valve should be used.
- All installations require a low-water cut-off or automatic fill valve on your boiler system to reduce the risk of boiler water loss.
- Steam boiler installations require a low-water cut-off which is also required by most codes.
- Installation of a vacuum breaker is required to prevent damage to the water heater when drained. There must be no valves installed between the vacuum breaker and the water heater.
Required Components
MODEL| CIRCULATOR| **ZONE VALVE*| SHUTOFF VALVE| VACUUM
BREAKER| RELIEF VALVE| THERMAL EXPANSION TANK|
DRAIN**
---|---|---|---|---|---|---|---
WH SERIES
| 4 GPM
@ 6 FT
| 3/4” Full Port or 1” STD| ****
4
| ****
1
| ****
Included
| ****
41 Gal. Models: 2 Gal.
| ****
Included
CH SERIES
| 4 GPM
@ 6 FT
| 3/4” Full Port or 1” STD| ****
4
| ****
1
| ****
Included
| 41 Gal. Models: 2 Gal.
80 Gal. Models: 4.4 Gal.
| ****
Included
IF CIRCULATOR IS NOT USED. ALL INSTALLATIONS REQUIRE AN ADEQUATE AMOUNT OF TEFLON® SEALING TAPE OR PIPE DOPE FOR THREADED JOINTS
Heat Exchanger Pressure Drop
Use this chart to select the proper circulator for your BOILERMATE®.
Installation – Domestic Water Piping
- Connect the cold water supply to the connection labelled COLD WATER.
- Connect the HOT WATER piping to the domestic hot water system.
- When all domestic water piping is complete, open the cold water supply and allow some water to enter the tank. Look and listen for signs of leaks and repair as necessary before continuing.
- Install the temperature & pressure relief valve and plumb a blow-down tube to within 6″ above a floor drain or as directed by the plumbing code.
WH Models
PIPING USING SEPARATE CIRCULATOR PUMP (RECOMMENDED)
PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR
CH Models
PIPING USING DEDICATED CIRCULATOR PUMP (RECOMMENDED)
PIPING USING ZONE VALVE WITH EXISTING HEATING SYSTEM CIRCULATOR
Mechanical Aquastat
Zone Valves
Other Applications
Installation – Boiler Piping
- Plumb the circulator or zone valve on the BOILER SUPPLY line.
- Pipe the BOILER RETURN connection to the boiler return line.
- Be sure the return line is NOT plumbed to the suction side of any heating circulators. This may require moving the heating circulator off the boiler and tapping on packaged boilers.
- Failure to do so will result in overheating and tank damage when the heating system is in operation.
- Install a weighted flow check on the boiler return line. This is not necessary for systems utilizing a zone valve to control the water heater temperature.
- After completing the boiler piping, slowly open the boiler fill valve and pressurize the water heater loop. Check for leaks and repair as necessary.
- Proceed to the appropriate wiring section in this manual. EXPLOSION HAZARD. Do not install a high-pressure steam boiler (greater than 15 psig).
Note: if your application is not shown, contact AMTROL Technical Support at 401.535.1216.
installation – Digital Control Wiring
- Ensure the control installation is within the following application and operating parameters:
- Ambient temperature from 38° to 125°F.
- Relative humidity ranges from 20% to 90% (non-condensing).
- Boiler load rating up to 15A resistive, 1/4hp inductive 120VAC.
- Circulator load rating up to 15A, 1/4hp inductive 120VAC.
- Space heating load rating up to 8A 120VAC.
NOTE
Line-voltage and safety-circuit wiring that is external to the water
heater jacket when all panels are in place, and which is part of the
appliance, shall be protected by metal conduit, metal-clad cable or raceways.
Thermoelectric wiring shall be exempt from this provision.
NOTE
Strain relief shall be provided for all conductors leaving an enclosure.
For low-voltage wiring, strain relief at the point of exit from an enclosure
is not necessary if, by wire location or support, protection is provided
against accidental strain.
Oil Burner Controls
Gas Valve Controls
Other Applications
Note: if your application is not shown, contact AMTROL Technical Support at 401.535.1216.
Installation – Digital Control Set-Up
After wiring per the appropriate diagram in this manual, insert the white temperature sensor (thermistor) plug into the receptacle at the base of the digital control. Zone valves can be slow actuating. Therefore, the zone valve sensor contains a built-in temperature offset to account for the time it takes the zone valve to fully close. This results in potable water temperature that is representative of the digital control temperature set point. This is why it is important to install the correct sensor into the digital control. See Page 3 for information regarding the selection of a circulator or zone valve. Temperature settings above 120° F can create a scald hazard.
Settings To adjust , press and hold the SET button until the Temperature setting appears. Cycle through settings by depressing the SET button and using the ▼ and ▲ buttons to change the settings.
Diagnostic Error Codes Codes clear automatically when corrected or can be reset by interrupting power to the control for 5 seconds.
To silence an alarm, depress the ▼ on the keypad.
Operating Indicators Water sensor temperature may be shown for 30 seconds by pressing the ▲ button.
Start-Up Procedure
- Purge Heat Exchanger: The heat exchanger should be free of large air pockets to allow the circulator to operate properly. Using the diagram below as a guide, isolate the boiler return line and flush the loop until large air pockets are purged. After this, the air elimination equipment will collect smaller air bubbles.
- Fill Tank: Open the hot water fixture furthest from the heater. Open the cold water supply and allow the water to run until air stops emerging. Air pockets may appear at any hot water fixture. This is considered normal and will clear as hot water is used.
- Start Heater: Turn the power on to the unit. Digital Control models come pre-set to 120°F for safety. Mechanical controls should have the knob rotated to the 120°F mark. The circulator or zone valve should operate and the boiler should start.
- Check Operation: The water heater will begin to heat. Depending upon the size of the water heater, the output of the boiler and the space heating load, the unit should typically reach the set temperature within 15 to 60 minutes. If heating does not occur, consult the troubleshooting section in this manual. Note: Large heaters coupled with small boilers may exceed this period upon initial startup.
- Set Temperature: The control should be set to the minimum temperature consistent with the user’s needs. This maximizes efficiency and reduces scald potential.
MAINTENANCE
The water heater and system should be periodically checked by a licensed professional at least annually and more often as the system ages.
WARRANTY
CH and WH Models: Six (6) year limited warranty on heat exchanger and tank
assembly only. Visit www.amtrol.com for complete warranty details.
Purging Heat Exchanger (CH Series Shown)
Troubleshooting
PROBLEM | POSSIBLE CAUSES | SOLUTION |
---|---|---|
No hot water | 1. No power to unit |
2. Circulator air-bound
3. Faulty circulator or zone valve
4. Faulty control
5. Boiler inoperable
| 1. Check the circuit breaker, boiler emergency switch and boiler reset switch.
2. Purge air. Ensure the circulator is on Boiler Supply. Check air vents.
3. Check the circulator and zone valve. Repair or replace if necessary.
4. Check continuity. Switching circuits should close. If not, replace control.
5. Check boiler system. The boiler must operate to generate hot water.
Insufficient hot water| 1. Demand exceeds capacity
2. Temperature too low
3. The boiler lacks output for simultaneous heat & hot water
4. Fouled heat exchanger
5. Insufficient heat exchanger flow
| 1. Check sizing based on household size and boiler output.
2. Increase temperature setpoint.
3. Set up for priority. If the problem persists add storage or increase tank size.
4. Check Boiler Supply/Boiler Return during cold startup. If the difference is less than 20°F, clean the heat exchanger as outlined below. Install water treatment equipment to prevent recurrence.
5. Check for undersized or faulty circulators and stuck or undersized zone valves. Ensure all shutoff valves are open. Check for stuck flow check valve. Purge the boiler loop to remove air.
Water too hot| 1. Improper plumbing
2. Temperature set too high
3. Temperature sensor not fully inserted
4. Stuck zone valve
5. Flow check valve stuck open
| 1. If the Boiler Return is plumbed to the suction side of a heating circulator, overheating will occur when the home’s heat is on. Fix plumbing.
2. Reduce temperature setting.
3. Re-insert temperature sensor.
4. Repair or replace.
5. Clean, repair or replace.
Relief valve dripping or opening| 1. Thermal expansion tank undersized or missing
2. Thermal expansion tank set improperly
3. City pressure too high
4. System over temperature
5. Faulty relief valve
| 1. Install the properly sized thermal expansion tank.
2. Ensure precharge air pressure matches static water pressure.
3. Install a Pressure Reducing Valve (PRV) if city pressure is over 80psi.
4. Determine the cause of temperature conditions and correct the problem.
5. Replace relief valve.
Discolored water at the faucet| 1. Poor water quality
2. Sediment or suspended particles
| 1. Have water tested for contaminants.
2. Install sediment filter, and purge unit more often to avoid future problems.
The boiler will not operate when calling for
hot water
| 1. Improper or loose wiring
2. The boiler high limit has been reached
3. Post Purge (POS) set too high
4. Problem with boiler system
| 1. Check connections against wiring diagrams in this manual.
2. The boiler will periodically cycle on and off during operation.
3. Post Purge shuts the boiler off before reaching the domestic setpoint. If set too high, the boiler may not have enough energy to raise the water temperature to the point. Reduce POS or set it to 0 if the problem persists.
4. Have the boiler diagnosed for proper operation.
Replacement Parts
Description | ID | WH Series | CH Series |
---|---|---|---|
Heat Exchanger Replacement, WH-41 Single Wall | **** |
1
| 2700-5000| –
Heat Exchanger Replacement, WH-41 Double Wall| 2700-5002| –
Heat Exchanger Replacement, CH-41 Single Wall| –| 2703R003
Heat Exchanger Replacement, CH-80 Double Wall| –| 2702R002
Mounting Panel Only, Mechanical Control| 2| 2704R498| –
Mounting Panel Only, Digital Control| 3| 2704R525| –
Mechanical Temperature Control| 4| 2704-093|
Digital Temperature Control w/Panel| 5| 940R101| –
Temperature Sensor, Digital Control| –| 2704-259| –
Cold Water Inlet Tube, CH-41| 6| –| 2703R001
Cold Water Inlet Tube, CH-80| –| 2702R001
T&P Safety Relief Valve| 7| 2700R1106| 2700R1106
Top Outlet Union Tee| 8| 2700-635| –
To obtain replacement parts, contact the installer or place of purchase.
Technical support is available by calling AMTROL at
401-535-1216.
1400 Division Road, West Warwick, RI USA 02893
T: 800.426.8765 F: 800.293.1519
www.amtrol.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>