blacklinessafety EXO Diffusion and Pump Conversion User Guide
- June 1, 2024
- blacklinessafety
Table of Contents
blacklinessafety EXO Diffusion and Pump Conversion
Product Usage Instructions
EXO Placement:
Refer to the EXO Technical User Manual for detailed information on placing
the EXO device.
Powering On EXO:
- Press and hold the power button for two seconds to turn on EXO.
- If you see an O2 stabilizing message, wait for stabilization before proceeding.
- After startup sequence, press OK to start the Setup wizard.
Menu Navigation:
- Press the center button to access the main menu.
- Use the up and down buttons to navigate through menu options.
Charging EXO:
Use recommended EXO accessories for charging. Detailed charging instructions
are available in the EXO Technical User
Manual.
Notifications:
Notifications are communicated through lights, sound, and on-screen messages.
Acknowledge and address triggering conditions before clearing notifications.
Green Light:
A flashing green light indicates no connection to Blackline Live. A solid
green light means active data transmission.
Blue Light:
The blue LiveResponse light indicates remote monitoring personnel are
responding to alerts.
Frequently Asked Questions (FAQ)
-
Q: What should I do if I encounter a dangerous gas level notification?
A: Follow your company’s safety protocol immediately. Leave the area as recommended by Blackline Safety. -
Q: How do I know if EXO is connected to Blackline Live?
A: A solid green light indicates that EXO is actively transmitting data and is connected to Blackline Live.
OVERVIEW
EXO is a cloud-connected area monitor that continuously measures gas concentrations in the ambient environment at sites, facilities, and fence lines. EXO activates notifications when concentrations of toxic and combustible gases exceed configured setpoints.
HARDWARE
- A. Siren/Lights
- B. Diffusion cartridge cover
- C. LCD screen
- D. Connectivity light
- E. LiveResponse light
- F. Navigation buttons
- G. Power button
- H. Microphone
- I. SOS latch pull/PTT latch push
- J. Speaker
- K. Battery retention screws
- L. Battery power gauge
- M. Battery pack
- N. Serial and information label
- O. Interface port A and B
- P. Power port
- Q. Manual calibration inlet
EXO PLACEMENT
When placing EXO:
- Keep EXO upright and accessible.
- Do not hang EXO by its handle.
For more information on placing EXO, see the EXO Technical User Manual.
POWERING ON EXO
To power on EXO:
-
Press and hold the power button for two seconds. EXO will sound a chime, the top lights will flash, the screen will display the active features on EXO, and the green connectivity light will stop flashing and become solid, indicating EXO is connected.
If you see an O2 stabilizing message on EXO’s screen, it means EXO is not monitoring. Stabilization typically takes approximately 10 seconds but can take up to 20 minutes if EXO has been powered off for a significant period. -
After you power on EXO and complete the startup sequence, EXO opens the main menu with Setup wizard selected. Press OK to start the Setup wizard.
EXO will continue to monitor for gas in the area during the Setup wizard. Low urgency notifications, an SOS latch pull, or dangerous gas levels will override the Setup wizard.
MENU
EXO’s menu is where you can access functionality such as gas options,
messages, settings, and advanced info.
To use EXO’s menu:
- Press the center button to open the main menu and confirm menu selections.
- Use the up and down buttons to navigate options.
CHARGING EXO
Use any of the following EXO accessories to charge EXO. For more information
on the accessories, see the EXO Technical User
Manual.
- Trickle Charger
- Solar Panel
- Quick Charger
NOTIFICATIONS
EXO communicates notifications using lights, sound, and an on-screen message
specific to the event. Notifications must be acknowledged, and the triggering
conditions addressed, before they can be cleared from the device.
IMPORTANT: Always follow your company’s safety protocol for responding to
notifications. For low and high urgency notifications, Blackline Safety
recommends leaving the area.
-
GREEN LIGHT
A flashing connectivity light indicates that EXO is not currently connected to Blackline Live and is not sending data. A solid connectivity light indicates that EXO is actively transmitting data and is connected to Blackline Live. -
BLUE LIGHT
The blue LiveResponse light lets you know that remote monitoring personnel are responding to an alert by following your organization’s emergency protocol. When monitoring personnel have confirmed the safety of everyone in the area and resolved the alert, the blue LiveResponse light will turn off. -
YELLOW LIGHT
Yellow lights indicate two types of notifications. Both types of notification include yellow flashing lights, sound, and an on-screen message specific to the event.- Operational:
- Triggered by routine and expected device operations.
- Local to your device; monitoring personnel are not notified.
- Low urgency:
- Triggered by an unexpected condition that could pose a safety risk if not addressed in a timely manner.
- Local to your device and monitoring personnel are not notified.
-
RED LIGHT
A red light at the top of your device indicates a High urgency notification.- Triggered by events that require your immediate attention and action.
- If your organization is monitored, high urgency notifications are immediately communicated to monitoring personnel and automatically generate an alert in Blackline Live.
To acknowledge and mute a notification:
- Press and hold the up and down arrow buttons at the same time to mute the notification and acknowledge the banner message.
NOTE: For continuous gas exposure, EXO will unmute itself after two minutes for low urgency and one minute for high urgency if detected gas levels have not returned to normal.
BUMP TESTING AND CALIBRATING
Bump testing and calibration verify that your device’s gas sensors and
notification indicators are functioning correctly.
IMPORTANT: If you are bump testing or calibrating EXO Diffusion in a
windy environment, you must use the wind guard.
To bump test or calibrate EXO:
- Connect a gas cylinder to EXO’s manual calibration inlet using calibration tubing.
- Press the OK button to enter the main menu.
- Select Gas options, and then select Bump test or Calibration.
- Confirm your selection by selecting Yes. EXO will run an audio/visual self test.
- Follow the screen prompts to complete the bump test or calibration, ensuring that you select all the sensors you want to test. You will be prompted to bump test or calibrate until all the selected sensors have been tested.
LEARN MORE
Visit support.blacklinesafety.com to
find support and training materials for EXO, including the comprehensive EXO
Technical User
Manual.