STERLING POWER BB1270 Saturn Battery Charger Instruction Manual
- June 17, 2024
- STERLING POWER
Table of Contents
Part No: BB1270
BB1270 Saturn Battery Charger
Sterling Power Products
12V to 12V 70A Battery to Battery Charger
Handbook
BB1270
E MARKING
E24 10R06/01 3789 00
TEMP1
Temperature sensor included
latest instructions https://sterling-power.com/products
/12v-to-12v-110a-dc-to-dc-charger-bb12110
INTRODUCTION
Dimensions drawing (not to scale)
Dimensions | 200mm x 130mm x 56mm |
---|---|
Weight | 1.0Kg |
WELCOME
Welcome to the Sterling Power Products Owners Handbook for the product
BB1270, the 12V to 12V battery to battery charger (70A input rated).
Please take your time to read and fully understand the contents of this
Handbook. These guidelines are developed with your safety and the products
performance in mind and failure to follow or understand these guidelines may
lead to voiding the product warranty or even leading to damage or injury for
you or your setup.
If you are unsure of any step or guideline then please consider reaching out
to Sterling via our web contact form or our phone service and we shall offer
our support.
Thank you for joining the Sterling family and we hope to serve your travels
well.
12V – 12V
70A
This 12V to 12V battery to battery charger is a device typically installed
between a starter battery (input) and a house / domestic / service battery
(output). The BB1270 is designed to charge up your 12V domestic / service /
auxiliary battery from the power generated from your alternator, whilst your
engine is running. It is designed to work with vehicles (old / new) and (boats
old / new). As this device is 70A rated on the input, we recommend running
from an alternator 90A+. This BB charges both lead acid style batteries and
lithium batteries.
Throughout this manual we will make reference to this product as the ‘BB’. The
term ‘12V’ is the nominal voltage, not the specific voltage.
Using this Handbook
This manual must be read throughout before installing this electronic
device. Do not lose these instructions – keep them safe. The most up to date
instructions can be found on sterling-power.com. Please refer to the latest
instruction manual before contacting Sterling. At Sterling, we endeavour to
include all of the product information that we can think of into the manual.
Installation of the electronic device must be carried out by qualified and
trained personnel only. The personnel must be familiar with the locally
accepted guidelines and safety measures.
Safety
Your safety is Sterling’s top priority. Please follow all precautions to
keep yourself safe. If you believe your unit requires repair then please
contact Sterling or your distributor. Do not attempt to service the unit
yourself.
Specifications
BB1270
Input voltage range | 9V-16V |
---|---|
Rated output power | 60A at 13.8V |
Rated input current | 70A |
Quiescent current | 10mA |
Efficiency rating | 92%-94% |
Self recovering protections: | under voltage protection input over voltage |
protection output over voltage protection over current protection
charge over temperature
Operational Temperature| -20 Deg C -> 60 DegC
Approval| CE | UKCA
E-Marking
Cooling method| Thermostatically Controlled Variable low speed fan
Dimensions| 200mm x 130mm x 56mm
Weight| 1.0Kg
SAFETY AND LEGAL
LEGAL GUIDELINES
Warranty and Terms
Your 100 % satisfaction is our goal. We realise that every customer and
circumstance is unique. If you have a problem, question, or comment please do
not hesitate to contact us. We welcome you to contact us even after the
warranty and return time has passed.
Each product manufactured by Sterling Power comes with at least a 2 year
limited factory warranty. Certain Products have a warranty period of time
greater than 2 years. Each product is guaranteed against defects in material
or workmanship from the date of purchase. At our discretion, we will repair or
replace free of charge any defects in material or workmanship that fall within
the warranty period of the Sterling Power product. The following conditions do
apply:
- The original receipt or proof of purchase must be submitted to claim warranty. If proof cannot be located a warranty is calculated from the date of manufacture.
- Our warranty covers manufacture and material defects. Damages caused by abuse, neglect, accident, alterations and improper use are not covered under our warranty.
- Warranty is null and void if damage occurs due to negligent repairs.
- Customer is responsible for inbound shipping costs of the product to Sterling Power either in the USA or England.
- Sterling Power will ship the repaired or warranty replacement product back to the purchaser at their cost.
If your order was damaged in transit or arrives with an error, please contact
us ASAP so we may take care of the matter promptly and at no expense to you.
This only applies for shipping which was undertaken by our company and does
not apply for shipping organised by yourself. Please do not throw out any
shipping or packaging materials. All returns for any reason will require a
proof of purchase with the purchase date. The proof of purchase must be sent
with the returned shipment. If you have no proof of purchase call the vendor
who supplied you and acquire the appropriate documentation.
To make a claim under warranty, call our customer care check telephone numbers
on www.sterling-power.com or www
.sterling-power-usa.com. We will make
the best effort to repair or replace the product, if found to be defective
within the terms of the warranty. Sterling Power will ship the repaired or
warranty replacement product back to the purchaser, if purchased from us.
Please review the documentation included with your purchase. Our warranty only
covers orders purchased from Sterling Power. We cannot accept warranty claims
from any other Sterling Power distributor. Purchase or other acceptance of the
product shall be on the condition and agreement that Sterling Power USA LLC
and Sterling Power LTD shall not be liable for incidental or consequential
damages of any kind. Some states may not allow the exclusion or limitation of
consequential damages, so, the above limitations may not apply to you.
Additionally, Sterling Power USA and Sterling Power LTD neither assumes nor
authorizes any person for any obligation or liability in connection with the
sale of this product. This warranty is made in lieu of all other obligations
or liabilities. This warranty provides you specific legal rights and you may
also have other rights, which vary from state to state. This warranty is in
lieu of all other, expressed or implied.
Copyright and Plagiarism
Copyright © 2021 Sterling Power. All rights reserved.
Reproduction, transfer, distribution or storage of part or all of the contents
of this document is strictly prohibited. If you wish to use all of this
document, or excerpts from it, Sterling Power must be contacted.
Liability
Sterling Power can not accept liability for:
- consequential damage due to use of this device
- possible errors in the manuals and the results thereof
Device Modification
Please do not modify the device unless you have been instructed to do so by
Sterling Power directly. Product modification shall be done at Sterling when
needed. Warranty shall be voided if personal attempts are made to modify the
device without Sterling’s approval.
Product Guidelines
Your Sterling Power product should only be utilised for it’s designated
purpose. Use the Battery to Battery Charger ONLY :
For DC to DC power conversion
With fuses protecting both the input and output DC cables
In a well ventilated, dry, dust-free and condensation free environment
When the Owners Handbook has been read and wholly understood
Transport and Storage
Ensure that the mains supply and battery leads are disconnected before
transporting or moving the unit. No liability can be accepted for damage in
transit once equipment has been unpackaged. Store the product in a dry
environment, between –20°C to 60°C.
Refer to the battery manufacturer’s manual for information on transportation,
stowage, charge rates, recharging and battery disposal for your battery care.
General Maintenance
The device must be switched off during maintenance and all cables removed
from the direct feed to or from the unit. It must also be protected against
unexpected switching off. Remove battery connections and ensure unit is off.
If repair is required, only use original parts. Unauthorised attempts to
repair Sterling units will lead to the warranty being voided. Only someone
with adequate understanding of electronics and the unit itself should attempt
a repair.
Ensure your connections are good and clean and aim to protect your unit from
humidity and water ingress.
Safety Precautions
Electrical appliances can be heavy. Please do not lift heavy units
unassisted.
Ensure that your product is correct for your intent. 12V battery. Incorrect
use can lead to damage.
Orientation is not critical to unit function, however may affect water ingress
rating.
Install device in a well ventilated space for cooling purposes.
Do not expose the unit to snow, rain, water, spray, condensation, pollution
etc, unless it is a waterproof unit. If it is a waterproof unit, only expose
it to situations it is correctly rated for.
Do not cover or obstruct the ventilation.
Device connects to common negative. Common negatives must be earthed.
In case of fire, use fire extinguisher equipment suitable for electrical
fires.
Avoid all possibilities of reverse polarity or short circuiting.
Check cabling and connections frequently and ensure the connections are
sufficient.
Always protect DC cabling with the appropriate fusing.
Ensure the unit is adequately and safely mounted to prevent displacement and
damage.
Always use a professional to install electrical products.
Ensure the product is correctly set up for your battery.
Keep out of reach of children
WARNING :
CROSS VOLTAGE THRESHOLD BATTERY TO BATTERY CHARGERS MUST BE INSTALLED WITH
CARE
A COMMON NEGATIVE IS PARAMOUNT TO OPERATION, HOWEVER, BE INCREDIBLY CAREFUL
NOT TO SHORT CIRCUIT OR REVERSE POLARITY ANY EQUIPMENT OR CABLE.
All electrical appliances carry the risk of electrical shock. This equipment
is designed to be used in combination with a permanent energy source (the
battery). Always isolate the DC before performing any maintenance or
inspection.
Do NOT remove the panelling to inspect the internals unless expressly told to
by Sterling. This is not a product designed to be user-serviced.
Do NOT use the device in situations where there is danger of gas / dust /
vapour explosions, or around potentially flammable produce.
PRODUCT INFORMATION
SIMPLE WIRING DIAGRAM
Basic installation diagram
Here, we hope to provide a very basic installation diagram for the vast
majority of installers to follow.
If a process is not mentioned here, the chances are that it is not a pre-
requesite to get the BB1270 to function.
The default charging profile is a standard sealed lead acid charging profile
of 14.4V and 13.3V float.
If you wish to charge a lithium battery, please refer to page 9 to change the
charging profile.
12V ignition signal, required for Euro 6 / Smart alternator use.
Ignition gives a binary on / off style signal to control the BB1270.
If ignition signal is not used, the BB needs to see 13.5V on the input
terminal to begin charging the output battery. When the input then drops below
12.8V the BB will stop charging.
Recommended installation orientation
The BB1270 can be mounted in any orientation. However, if the area is prone to
getting wet or damp, we recommend the first or second install.
UNDERSTANDING YOUR BB1270, PT.1
BB1270 Diagram
*Label rendered for clarity,
- The top mounting plate. Composed of 2x 5mm wide mounting feet. There are 2x 5mm wide mounting feet at the bottom, too.
- Location of 2x heat extracting fans. The air is sucked through the BB and the direction of air flow is demonstrated above.
- Display panel. More information on page 9.
- Connection blocks. This region is described in more detail overleaf. This is the area where all the physical installation connections to the BB1270 are made. Also, this region contains additional 2x 5mm mounting feet.
BB1270 Diagram
*Label rendered for clarity,![STERLING POWER BB1270 Saturn Battery Charger
-
Diagram 2](https://manuals.plus/wp-content/uploads/2024/02/STERLING-POWER- BB1270-Saturn-Battery-Charger-Diagram-2.png)
-
The left large green connector is for direct connection to the input / starter battery. 12V input connection. Ensure the cable thickness is 16mm2 / 6AWG. Ensure this cable is fused at ~80A fuse.
-
These 2 central connectors are for common negative cable. For convenience, use the left GND to connect to the input battery’s negative and use the right GND connector to connect to the output battery’s negative. Use similar sized cable as positive.
-
The right large green connector is for direct connection to the output / leisure battery. 12V output connection. Ensure the cable thickness is 16mm2 / 6AWG. Ensure this cable is fused at ~80A fuse.
-
This 12V output provides a 12V signal at 50mA. This can be used to trigger an operation / provide a 12V signal.
This 12V signal shall only become live if the Ground connector (11) is connected to the common negative rail. -
Ignition feed connector. The BB1270 can be operated based on an ignition signal – this is recommended if you have a smart alternator (Euro 6 engine). Wire a feed from your ignition into this terminal. Ensure that this feed is ~12V when the ignition is live and goes to 0V when ignition is turned off. Once the BB1270 receives its first successful ignition signal it shall render the unit dependent on an ignition signal going forward. Therefore, the BB shall not operate based purely on input voltage coming from the input battery but based on whether your ignition is live or not. You can reset this feature by removing the ignition feed and pressing / holding the front button down for 15 seconds and letting go.
-
Alarm. If the BB faults – this alarm connector shall put out a live 12V | 100mA. Therefore, you can wire in an audible 12V alarm or a 12V light / LED to convey a fault. These are optional fits. You can also use this connector to relay a 12V signal to another device to prompt an action if the BB were to fault. Ground connector (11) must be connected to the common negative rail for this alarm output to operate. More information on page 11.
-
Ground. To utilise connectors 8 or 10, a ground / negative (0V) feed needs to be connected here. For the ignition feed connector to operate, a negative feed is NOT required.
-
Vibration sensor on / off switch. Default off. If turned on, the BB1270 shall begin charging when the vibration sensor detects 2x vibration events. This shall override the ignition signal and allow you to install the BB without the need to install an ignition signal. This is also an operational method if you have a smart alternator / Euro 6 engine (or younger). This mode comes with cautions, please read page 10. Switching between on / off can be done at anytime. There may be a 10 second delay in unit operation between switches – no need to reset / reconnect the BB.
-
Temperature sensor connector. Here is where to install the temperature sensor – TEMP1. Connect the terminal end of the temperature sensor to the negative terminal of the output battery. If in a Lead or AGM setting the temperature sensor compensates the voltage being delivered by the charger based on sensor temperature. If in a lithium setting, there is no voltage compensation. In lithium, the charger stop charging if sensor detects 0DegC or lower.
-
For remote control connection – BBR
-
PANEL Controls | Battery Type Select
LED panel
Lead Acid Charging Profiles
Orange LED status:| Lithium Charging Profiles
Orange LED status:
---|---
Fast flashing = Bulk / Fast Charge
Slow flashing = Absorption
Solid = Float| Fast flashing = Bulk / Fast Charge
Slow flashing = Absorption
Orange LED status:
Fast flashing | Low battery voltage, battery needs a good charge |
---|---|
Slow flashing | Medium battery voltage, mid charge. |
Solid | Good battery voltage, nearer charge completion. |
Battery Type Select
When charger is on, press and hold the Select button for 5 seconds until the LEDs flash. Then, press the Select button to toggle through the 6 different battery types – the flashing orange LED shall depict the battery type. Type 2 LED shall light up to display the second profiles of the battery types. Once you have the LED on the battery type you, want wait until the LED stops flashing – after a few seconds the flashing stops and the LED stays on solid – this confirms setting.
Absorption time lengths:
As the BB can measure both current and voltage it shall make an intelligent
decision as to when to transfer from absorption to float mode. This algorithm
detects both the rate of rise of voltage and the rate of decline of current.
If the target absorption voltage has been met and the current has dropped to a
few amps the charger shall transfer to float mode.
LED sequence | Battery Type | Absorptions (V) | Float (V) |
---|---|---|---|
Lead I | 14.4V | 13.3V | |
Lead II | 14.6V | 13.5V | |
AGM I | 14.2V | 13.1V | |
AGM II | 14.7V | 13.6V | |
Lithium I* | 14.4V | 13.8V | |
Lithium II* | 14.2V | 13.6V |
Lithium* = live output voltage, ideal for waking up BMSs on batteries. Please
ensure your lithium battery has an internal or external BMS. If you want a
float voltage please use Lead or AGM profiles.
If temperature sensor connected, no voltage compensation on lithium profiles.
If temperature sensor detects 0 Deg C – BB stops charging.
Float to absorption trigger
voltages. If the charger is in float and the output batteries voltage is
dragged below the following voltages the charger shall go back to absorption.
Lead I = 12.6V
Lead II = 12.7V
AGM I = 12.4V
AGM II = 12.8V
Lithium I = 13.4V
Lithium II = 13.2V
Charge control modes – how to get the BB1270 to turn on and begin charging
Automatic Mode (Default)
This mode is the simplest way to install the BB1270, however, not the most
effective if you are using this BB on a modern vehicle that has regenerative
braking (Euro 6 engine or newer).
To activate the BB, you require 13.5V+ on the input terminal. You shall
achieve this voltage by charging up your input battery (starter battery) with
an alternator (for example).
When the input voltage drops below 12.8 (when you turn your engine off), the
BB shall turn off and go to sleep.
Input voltage
Charger on – 13.5 -> 16V
Charger off – <12.8V
Ignition feed Mode (requires 12V signal feed)
In this mode you control the BB based on an ignition signal. Essentially when
you are running your engine the signal is ~12V and BB works. When you turn
your engine off – signal turns to 0V – the BB turns off.
The BB also requires 11.0V+ on the input battery. If starter battery is lower
than this w/ live ignition, BB will not work.
WARNING, if ignition is live, but engine not running, flat starter
battery!
Input voltage + ign feed.
Charger on – 11V -> 16V
Charger off – <10V
By applying a live signal to the ignition connector you put the BB into
ignition dependent mode. The BB shall NOT work unless it has a live ignition
signal – even if you remove the ignition feed cable and provide 13.5V+ onto
the input terminal.
To reset the BB back to Automatic Mode, ensure BB is on –
I) Remove ignition cable from ign connector.
II) Press and hold SETUP button for around 15 seconds until the 3 LED battery
types flash at the same time.
III) Release button and charger reverts to Automatic Mode.
Vibration sense
Switch position ON.
This mode requires the BB to detect 2 vibration events in order for it to turn
on and charge. For example, turning an engine on shall provide sufficient
vibration to get the BB to begin charging.
This mode essentially acts like an ignition signal and is designed for
installers to do away with having to run an ignition feed.
WARNING, if vibration signal activates BB, shall drag starter battery
voltage to below 11V. Possible flat starter battery! The BB does monitor the
input battery and shall turn off after 2 minutes if the voltage does not climb
up.
Input voltage + vib. sense.
Charger on – 11V -> 16V
Charger off – <10V
Troubleshooting & Faults
Troubleshoot – checks to ensure the BB is installed correctly and receiving
the correct input and output voltages.
Firstly, ensure the BB1270 is wired up correctly. Ensure negatives are common
and the BB charger’s negative is connected to the starter battery’s negative –
avoid connecting to chassis negative. Voltages between common negatives should
be ~0V.
Secondly, to test the BB, remove (or turn off) any secondary charging source
like AC to DC battery chargers or solar chargers going to the battery banks.
Leave the primary charger connected (alternator) – ensure alternator is
working. We also recommend turning off any loads (inverters etc.).
How to test if the BB is charging:
With engine running (alternator charging), what is the voltage on the input
terminal of the BB? What is the voltage on the output terminal of the BB?
Measure these voltages at the BB’s terminals, not at the batteries terminals.
By default, the BB requires 13.5V+ to turn on and get going. If you are
getting alternator voltage at the input terminal (~14V) and 14V+ on the output
terminal the chances are your BB is working fine. If little to no current is
passing through the charger at these voltages then the batteries are either
full or they are duff. If the output voltage is between 13V-14V (but rising)
then you could have a situation where the output batteries were very low in
charge (or large in capacity) and the charger shall be charging at maximum
current. Provided this output voltage continues rising the BB is charging.
If your output voltage is less than 13V and your input voltage is healthy,
it could be three things:
- You have a large load on your output bank – turn load off.
- The BB may have enter a fault state an stopped charging.
- The BB is not working / failed.
If your input voltage is less than 13V, it could be several things:
Automotive: Your alternator’s voltage is at less than 13V (the alt. is in
regenerative braking mode – sometimes expected on modern Euro 5/6+ engines) –
take vehicle for drive and measure alternator’s voltage and set up the BB to
suit these needs. All vehicle manufactures have their own software /
characteristics for regen. braking. Resort to running ignition signal to BB to
ensure BB operates irrespective to fluctuating input voltage.
What output current rates to expect at lower input voltages
input voltage | output A |
---|---|
>13.6V | ~60A |
12.8V – 13.6V | ~55A |
<12.8V | ~45A |
Automotive or Marine: If your alternator’s voltage is ~14V then check
continuity between the alternator’s B+ terminal and the starter battery. If
you are getting ~14V on starter battery then check continuity between starter
battery and BB input terminal.
Automotive or Marine: If your alternator’s voltage is 0-13V (starter battery
voltage) then alternator may have failed. Or, requires increase rpm of engine,
possible belt slip.
Is your output voltage slightly higher or lower than expected – even with
no loads / chargers on?
Check if you have the temperature sensor connected. If so, no problems leaving
it there, it is simply voltage compensating for when the temperature at the
sensor is lower or higher than the benchmark 20DegC (69F). If lower, then the
voltage shall rise and vice versa. The further from 20DegC in either direction
leads to proportional increase or decrease in the voltage.
If the voltage at your output battery is 0.3V lower (or more) than at the
output of the BB – this is likely due to poor / thin cabling. And / or, due to
voltage drop across fuses / fuse holder / isolation switch / relay / diode
etc.. between the output of the BB and your output battery. Beef up the cable,
clean connections, ensure connections are as tight as possible, remove
unnecessary devices (such as isolation switches, relays or diodes) – these are
really not required here.
Fault LED – shall come on solid, if a fault is detected.
This LED is red colour.
The fault can be a single fault or multiple faults. There are 6 faults that
can be detected – all of which are mentioned in this table.
Problem| Possible Cause| Suggested solution| Recovery
Condition
---|---|---|---
Low Voltage Disconnect (LVD) on input – in Auto Mode| input voltage is lower
than 12.8V or no ignition signal is detected.| Turn engine on | ensure cable
thickness between input and starter battery is sufficient.| The fault shall
clear automatically when input voltage rises above 13.5V.
Low Voltage Disconnect (LVD) on input – in Ignition / Vibration Mode| input
voltage is lower than 10V and/or no ignition signal is detected.| Turn engine
on | ensure cable thickness between input and starter battery is sufficient.
~12V at ignition| The fault shall clear automatically when input voltage rises
above 11V + live ignition / vibration signal
Output Over Voltage Protection (output OVP)| output voltage has exceeded 0.6V+
on top of set absorption voltage.| check loads or chargers on output battery.
C.heck where high V is coming from| When output voltage drops below 0.3V on
top of set absorption voltage the BB resumes charge.
Input Over Voltage Protection (input OVP)| input voltage has exceeded 16V.|
likely alternator voltage has gone too high. If Euro 6 vehicle – this is okay,
BB shall reboot when V drops.| When voltage drops below 15.5V the BB shall
turn on and resume charging after 30 seconds.
Over Temperature Protection (OTP)| Charger’s internal temperature is too high|
Check input and output exhausts for blockages. 10mm| When charger temperature
reduces charging resumes
Fan Fault| Failed fan| objects may be jamming the fan, fan may be old, clogged
up.| When fan is operational the fault light turns off.
If the BB’s performance is reduced it could be because of voltages or
temperature:
This table shows the performance down rating of the BB when input voltage
drops at the input terminals of the BB. If you have a 24V input model, simply
double the voltage values.
Criteria | Output Power (% of Rated Current) | Remark |
---|---|---|
Input voltage less than 12.8V + live ignition | 65% | Power reduction due to |
impotent alternator performance / Euro 6 and/or poor connections
Input voltage less than 13.2V but higher than 12.8V + live ignition| 85%|
Power reduction due to impotent alternator performance / Euro 6 and/or poor
connections
Input voltage 13.5V or higher| 100%| Charger performance back to normal.
This table shows the performance down rating of the BB when internal
temperatures rise to certain DegC.
Temperatures could rise due to:
- High ambient temperatures.
- High continuous working with moderate ambient temperatures.
- Fan could be impeded, deteriorating or failed.
Criteria | Output Power (% of Rated Current) | Remark |
---|---|---|
If the temperature sensor in the inductor reaches ~105 DegC+ | 0% | The charger |
shall simply stop charging and wait to allow the unit to cool down
If the temperature sensor in the inductor reaches ~100 DegC+| 65%| Power
reduction due to high internal temperature.
If the temperature sensor in the inductor reaches ~90 Deg C+| 85%| Power
reduction due to high internal temperature.
If the temperature sensor in the inductor is <75 Deg C| 100%| No power
reduction.
These temperature are accurate based on +/- 5DegC
www.sterling-power.com
www.sterling-power-usa.com
Warranty (2 years return to factory)
Copyright © 2022
Sterling Power
All Rights Reserved
Documents / Resources
|
STERLING POWER BB1270 Saturn Battery
Charger
[pdf] Instruction Manual
BB1270 Saturn Battery Charger, BB1270, Saturn Battery Charger, Battery
Charger, Charger
---|---
References
- Sterling Power USA, Marine Grade AC Battery Chargers, Marine Battery Isolator, Advanced Alternator Regulators, DC Powered Battery Chargers & Alternator Powered Battery Chargers, Pro Connect Advanced Battery Relays, BB Chargers, Current Limiting Units
- Sterling Power Products
- Sterling Power USA, Marine Grade AC Battery Chargers, Marine Battery Isolator, Advanced Alternator Regulators, DC Powered Battery Chargers & Alternator Powered Battery Chargers, Pro Connect Advanced Battery Relays, BB Chargers, Current Limiting Units
- Sterling Power Products