EAGO DA333F8 Steam Shower Tub Combo Instruction Manual
- June 17, 2024
- EAGO
Table of Contents
- EAGO DA333F8 Steam Shower Tub Combo Instruction Manual
- Important safe information
- Installation wiring diagram
- Electrical parts specification
- Parts instruction
- Technical drawing for water and electricity
- Installation instruction
- F8 Control panel keys and operating instructions
- User’s manual for cleaning the steem generator
- Maintenance service card
- Steam shower room trouble shooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EAGO DA333F8 Steam Shower Tub Combo Instruction Manual
EAGO
EAGO Sanitary Ware Co. ,Ltd,
Factory Add:Shiling Development Zone,Xiaotang Town , Nanhai District, Foshan
City,Guangdong ,China
National Service Hotline 800-8301359
Important safe information
- Please read this instruction and assemble the steam shower according to it.
- The leakage protection switch must be installed. Besides, please try it to check whether it is safe enough before formal using.
- To avoid being shocked by the electricity, users are not allowed to install or replace wires by themselves, please ask a professional electrical engineer to do such work.
- The ground line of the product must be connected to the earth permanently.
- There is a ground wire on the pump, to avoid being shocked by the electricity, users should connect this wire to the ground. The diameter of the cooper-core wire shouldn’t less than 1.5square millimeters.
- To avoid being hurt, it is strictly forbidden to touch the pump while it is working.
- It is not allowed to refit, append or scissor the steam shower and bathtub.
- It is strictly forbidden to use the steam shower after drink or eat some hypnotic medicine.
- Children should be guided by parents while using.
- Do not use any strong chemical liquid such as Vitriol, Hydrochloric acid, Lye and so on to clean the steam shower.
- Please be sure the water level should be above all the jets before press the Pump Key.
- If you use the massage function, please be sure not block the Water Filter.
- If the steam shower with 3KW/4.5KW/6KW steam generator, the diameters of wires which are used not less than 2.5squre millimeter/ 4squre millimeter/ 6squre millimeter.
- Especially note: The using water temperature should not pass 60 centigrade or 140 Fahrenheit.
- Warning: To avoid being shocked by the electricity, please be sure to connect the DFCI/RCD to the ground plug. It is not allowed to take off the Self-cleaning Cup Lid during using the steam function, or the steam will jet out to hurt users.
Installation wiring diagram
Electrical parts specification
Parts instruction
Parts package
Technical drawing for water and electricity
Size: 1500mmX1500mmX2260mm
Installation instruction
Install the shower base
1. Take the shower base out from the carton and put it on the floor
carefully.
2. Put the level ruler on the shower base to check the level Adjust the
adjustable leg if the shower base is not horizontal. Illustrated in the
drawing A.
Install the back panels
1. Take the No.1 panel out of the carton and put it on the shower base
carefully.Please be sure to make one person to stand beside to hold it on
safely.
2. Take the No.2 mid panel out and put it beside of the No.1 back panel
carefully. Insert the No.2 panel to the aluminum profile of the No.1 back
panel. Then make one person hold on the No.1 and the No.2 panels, the other
person uses a Philip Screwdriver to fix them with 4x10mm self-locking screws.
Illustrated in drawing A. Use the same way to fix the No.3 right back panel to
the No.2 mid back panel as well.
Install front fixed glass doors
1. Put the No.1 lower aluminum track on the floor. Slide the No.2 left fixed
door into the No.1 track, then use a Phillip Screwdriver to fix No.1 and No.2
together with 3.5x30mm self-locking screws. Illustrate in the drawing A.
2. Slide the No.2 left door into the No.4 upper aluminum track, use a Phillip
Screwdriver to fix them together with 3.5*30mm self-locking screws as
well.Also according to the illustration in the drawing A.
3. Use the same way to install the No.3 right fixed door to the No.1 and No.4
aluminum tracks .
Install the Fixed Glass Doors to the Back Panels and the Shower Base
1. Cover the No.5 right corner aluminum profile onto the No.3 right installed
fixed glass doorframe (Illustrated in drawings A).
Use the same way to cover the No.6 left corner aluminum profile on the No.2
left installed fixed glass doorframe.
2. Please ask two persons to carry on the left and the right installed fixed
glass doors, and put them on the shower base carefully.
Then one person holds on the glass doors, another person uses a Phillip
Screwdriver to fix them to the left and the right back glass panels with
4x10mm self-locking screws. Illustrated in drawing B.
Install Movable Door.
Hang up the movable door to the upper aluminum track (Illustrated in the
drawing A), and then press the lower wheel to hook it into the lower aluminum
track (Illustrated in the drawing B). Note: There is a Spring in the Upper
Wheel. If there is a gap between the Movable Door and the Fixed Door, or the
Movable Door can not swing very well, please adjust the Upper Wheels.
Adjust Way: Use a Phillip Screwdriver to adjust the Screw at the bottom of the
Upper Wheel, to make the Movable Door vertical.
Install the handles with a Hexangular Wrench. Illustrated in the drawing C.
Install Accessories
1. Install the Glass Shelf: Use a Phillip Screwdriver to fix the Glass Clip
to the back panel with 4x16mm screws, 4mm plastic cushion, 6mm plastic cushion
and 4mm nuts, illustrated in the drawing A. Then put the Glass Shampoo Holder
on the track of Glass Clip and use a Phillip Screwdriver to fix them well.
Illustrated in the drawing B.
2. Install the Up and Down Hand Shower Socket: Use a Phillip Screwdriver to
install the Up and Down Hand Shower Socket to the back panel with 4x16mm
screws, 4mm plastic cushion, 6mm plastic cushion and 4mm nuts. Illustrated in
the drawing C.
3. Connect the hand shower chain to the hand shower socket. Illustrated in
the drawing D.
4. Fix back panels to the shower base with 6x30mm screws, 6mm spring cushion,
12mm stainless steel cushion and so on. Illustrated in the drawing E.
Connect Wires
1. Put the top cover onto the steam shower carefully (Illustrated in the
drawing A).
2. Use a Phillip Screwdriver to fix the Top Cover to Back Panels with 4x10mm
self-locking screws and Stainless Steel Cushion. Illustrated in the drawing B.
3. Find out the Ventilator sign, the Lamp sign, and the Loud Speaker sign
which are on the behind of the back panel, then connect the relative wires of
these spare parts to the relative sockets. Illustrated in the following
drawing.
Connect Fittings and Water Pipes
1. Connect the head shower pipe to the head shower joint. Connect the water
outlet pipe to the shower base and connect the steam pipe to the steam outlet,
illustrated in the drawing A.
2. Connect the hot water inlet pipe and the cold water inlet pipe separately
to the relative joints. Illustrated in drawing A, B and C.
3. Especially note: T he thermostatic faucet is an optional function, just
when customers require to install this spare part and we will do, the standard
steam shower is without the thermostatic function. Illustrated in drawing D
and E.
F8 Control panel keys and operating instructions
User’s manual for cleaning the steem generator
Notice:
- Strictly prohibit to use the cleaning function while any other function is on;
- Strictly prohibit to use any other alkaline cleaning compound to clean steam generator;
Strictly prohibit to use any solid cleaning agent to clean steam generator, in order to avoid blocking the pipe.
We recommend that you use citric acid solution to clean steam generator!
Maintenance service card
Eago guarantees to keep:
Eago series’ products in good repair against the maintenance service card and
purchasing receipt since the purchasing date. If it Is the product quality
problem, it will be free maintenance or change the spare parts. If the problem
is not caused by the products itself or over-exceed the one-year guarantee, it
will charge the repairing fees and spare parts costs.
Steam shower room trouble shooting
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>