Warnings

  • Electric shock: Disconnect or turn off power before installing or servicing luminaire.
  • All electrical wiring to be completed by a qualified licensed electrician in accordance with local and National/Canadian Electrical Code.
  • Ensure supply voltage corresponds with the correct ballast/driver voltage.
  • Avoid exposing wiring to metal edges and sharp objects. Ensure that the luminaire is properly grounded to prevent electric hazards. Before powering up fixture, perform appropriate testing to ensure the fixture is properly grounded.
  • Fire: Keep flammable and combustible materials away from the light source and/or lens. Use correctly rated supply conductors as indicated by product labeling.
  • Burn: Allow luminaire to cool before handling luminaire.
  • Personal Injury: Wear safety glasses and gloves when handling the luminaire to avoid physical injury. Avoid direct eye contact with light source. Always support the weight of the luminaire.
  • Intended Use: Certain airborne contaminants can diminish integrity of acrylic and/or polycarbonate. Certain airborne contaminants may also adversely affect the functioning of LEDs and other electronic components, depending on various factors such as concentrations of the contaminants, ventilation, and temperature at the end-user location. Failure due to the effect of contaminants is not covered under our standard terms of warranty. Manufacturer is not responsible for any injuries due to the improper installation or handling of its products.

Product Usage Instructions:

Suspended Mount`A’ Size Stem Mount

  • 48

  • 37

  • `B’ Speedy Hanger, Surface, Chain, A/C

  • 39

  • Length `C’

  • Speedy Hanger, Chain, Surface, Air Craft Cable, & Stem –
    `B’

  • `C’ Length

  • 45 1/16

  • 2- 11/16 Knock-outs At each end

  • 3 -7/8 Knock-outs

Sliding Mounting Bracket for Surface Mount (Optional for Suspended Mount)

  • Length `C’
  • Recommended Location for Stem Mount `A’
  • 2- 11/16 Knock-outs At each end
  • 3 -7/8 Knock-outs
  • Optional Sliding Mounting Brackets (2pcs.)

Surface Mount Instructions

Squeeze at these point locations to release lower sub-assembly from housing

  1. Remove the 2 screws on only one side.
  2. Squeeze tabs to release from housing and disconnect the ballast quick-connect wiring.
  3. Punch out knock-out at preferred side.
  4. From page one, use hole location to fasten channel to surface by using #1/4-20 screws (Hardware by others).
  5. Disconnect/Turn-Off power. Make the necessary wiring connections and ground connections in accordance with local electrical and/or building codes.
  6. Re-install lower reflector sub-assembly compartment.

Release Tabs located on reflector to disconnect from housing

FAQ

  • Q: What should I do if I experience an electric shock?
    A: If you experience an electric shock, immediately disconnect or turn off the power before taking any further action. Seek medical attention if necessary.

  • Q: Can I complete the electrical wiring myself?
    A: All electrical wiring should be completed by a qualified licensed electrician in accordance with local and National/Canadian Electrical Code.

  • Q: How do I ensure the luminaire is properly grounded?
    A: To ensure proper grounding, avoid exposing wiring to metal edges and sharp objects. Perform appropriate testing before powering up the fixture to ensure it is properly grounded.

  • Q: Can I install the luminaire near flammable materials?
    A: No, it is important to keep flammable and combustible materials away from the light source and/or lens to prevent fire hazards.

  • Q: What precautions should I take when handling the luminaire?
    A: When handling the luminaire, wear safety glasses and gloves to avoid physical injury. Avoid direct eye contact with the light source and always support the weight of the luminaire.

  • Q: What is the intended use of the product?
    A: The product is intended for use in various environments, but it is important to note that certain airborne contaminants can diminish the integrity of acrylic and/or polycarbonate. Additionally, certain contaminants may adversely affect the functioning of LEDs and other electronic components. Ensure proper ventilation and consider the concentration of contaminants in the end-user location.

LHBU Series Installation Instruction

ERP: IIS00378 Date: 07/14/2023 Rev 1.0

NOTES

  • Installation should be completed by an individual familiar with the construction and operation of the luminaire.
  • Installation of luminaire must be in accordance with national and local building and electrical codes.
  • Carefully read and follow all warnings and instructions before installing or servicing the luminaire.
  • Instructions do not cover all details and all possible product configurations
  • Do not restrict luminaire ventilation.
  • Ensure LED luminaire is not covered with material that will prevent convection or conduction cooling.
  • Do not exceed luminaire’s maximum ambient temperature.
  • Ensure LED luminaire has the correct polarity before installation.
  • These products have maximum rated output voltage that exceeds the voltage limits that cannot be accessible based on voltage restrictions for Class 2 circuits in Canadian Electrical Code. This output complies with the definition of Class 2 per Canadian Electrical Code. This product complies with this requirement

WARNINGS

Electric shock:

  • Disconnect or turn off power before installing or servicing luminaire.
  • All electrical wiring to be completed by a qualified licensed electrician in accordance with local and National/Canadian Electrical Code.
  • Ensure supply voltage corresponds with the correct ballast/driver volt- age.
  • Avoid exposing wiring to metal edges and sharp objects.
  • Ensure that the luminaire is properly grounded to prevent electric haz- ards.
  • Before powering up fixture, perform appropriate testing to ensure the fixture is properly grounded.

Fire:

  • Keep flammable and combustible materials away from the light source and/or lens.
  • Use correctly rated supply conductors as indicated by product labeling.

Burn

  • Allow luminaire to cool before handling luminaire. Personal Injury:
  • Wear safety glasses and gloves when handling the luminaire to avoid physical injury.
  • Avoid direct eye contact with light source.
  • Always support the weight of the luminaire.

Intended Use:

  • Certain airborne contaminants can diminish integrity of acrylic and/or polycarbonate.
  • Certain airborne contaminants may also adversely affect the functioning of LEDs and other electronic components, depending on various factors such as concentrations of the containments, ventilation, and temperature at the end-user location.
  • Failure due to the effect of contaminants is not covered under our standard terms of warranty.

Manufacturer is not responsible for any injuries due to the improper installation or handling of its products.

Viscor-LHBU-Series-Ceiling-Light- \(1\)

SUSPENDED MOUNT

Viscor-LHBU-Series-Ceiling-Light- \(2\)

SLIDING MOUNTING BRACKET FOR SURFACE MOUNT (Optional for Suspended Mount)

Viscor-LHBU-Series-Ceiling-Light- \(3\) Viscor-LHBU-
Series-Ceiling-Light- \(4\)

Instructions for Surface

  1. Remove the 2 screws on only one side.
  2. Squeeze tabs to release from housing and disconnect the ballast quick-connect wiring.
  3. Punch out knock-out at preferred side
  4. From page one, use hole location to fasten channel to surface by using #1/4-20 screws (Hardware by others).
  5. Disconnect/Turn-Off power. Make the necessary wiring connections and ground connections in accordance with local electrical and /or building codes.
  6. Re-install lower reflector sub-assembly compartment. Viscor-LHBU-Series-Ceiling-Light- \(5\)

Instructions for Suspended Mounting

  1. Use suitable mounting hardware (see mounting accessories on spec sheet) to make connection to ceiling by means of chain or aircraft cable.
  2. Punch out knock-out at preferred side and make the necessary wiring connections and ground connections in accordance with local electrical and /or building codes.

Instructions for Stem Mount

  1. Use sliding mounting bracket to position to the recommended location as per table on page 2.
  2. Tighten with built-in screw to lock in sliding mounting bracket.
  3. Punch out knock-out at preferred side and make the necessary wiring connections and ground connections in accordance with local electrical and /or building codes.