Jitesy KT09 IPL Hair Removal Device User Manual

June 16, 2024
Jitesy

Jitesy Logo IPL Laser Hair Removal Device
User’s Manual
(Household type)Jitesy KT09 IPL Hair Removal
Device

Please operate this product under the guidance of a professional

General Information

1.1 Instrument description

  1. Depilatory apparatus
  2. Ice cooling function
  3. Cycle Icon
  4. Skin occlusion sensing
  5. 6 gear sizes
  6. Power switch / gear adjustment
  7. Light out button
  8. Air inlet
  9. Charging port
  10. Air outlet

Jitesy KT09 IPL Hair Removal Device - Air

1. 2 Package details
Open the outer box and inner box to find the following items
♦ Hair removal device
♦ Power adapter
♦ Instruction book
♦ Shaver Sunglasses

1.3 Product specifications

Instrument principle IPL Photon beauty technology
Net weight of instrument 210g
Irradiation area 3.2CM

2
Instrument spectrum| z530nm
Rated voltage| 12V-3A
Input power| 36W
Operating environment| Temperature: -10° – 35° Humidity:30%-75%

Product Description

The instrument adopts the international advanced photon cosmetology IPL technology. IPL laser is a light-heat irradiation technology to treat skin.
Strong pulse light is used to directly irradiate skin hair follicles to generate photo biochemical effects. On the one hand, it can rearrange the regeneration of collagen fibers and elastic fibers in skin, restore skin elasticity, improve facial micro circulation, and eliminate or reduce wrinkles; on the other hand, strong pulse light energy penetrates the skin and is preferentially and selectively absorbed by pigment groups and capillaries in the tissue; on the premise of not damaging normal skin tissues, the heat energy causes blood to solidify and the pigment groups to be thermally decomposed and destroyed, thereby treating capillary dilation, removing color spots, removing redundant hair and the like. This technology is developed by a global leading beauty company and applied by global beauty experts to reduce the function of hair follicles, remove excess hair for a long time, be gentle and easy to operate, fast, instantly have silky smooth skin, and no longer have the confusion of shaving and waxing.

Users and contraindications

3.1 Users
The depilator is an instrument suitable for men and women to remove excess hair. It is a purely physical process. According to the treatment schedule, it can be used to remove hair for a long time. Some parts do not need follow-up maintenance, while some parts need 6 months, 9 months, 12 months for subsequent maintenance at different times.
3.2 Unsuitable population/ contraindications

  1. People with suitable skin
    Please ref er to the skin comparison chartJitesy KT09 IPL Hair Removal
Device - Fig

  2. If the skin type is VI, please do not use this instrument, otherwise it is likely to cause adverse reactions to the skin, such as pigmentation and pigment shedding, severe redness or scorching.

  3. Do not use this instrument for pregnant or nursing women, as the instrument has not been tested for pregnant or nursing women.

  4. Epilepsy or light-induced epilepsy or chronic migraine patients are forbidden to use. Luminescence may cause severe head discomfort or migraine symptoms when such patients use instruments.

  5. Those with implanted devices in the body are forbidden to use, such as cardiac pacemakers, incontinence devices, insulin pumps, silicone implants, heart rate regulators, subcutaneous injection ports, body piercing or other artificial substances. This instrument has not tested this population, so its function is not clear.

  6. Please do not use this instrument when taking any of the following drugs
    1 DAt present and in the past week, the skin has been treated with a-amino acid(AHA), B-hydroxy acid(BHA), local isotretinoin and azelaic acid;
    2Those who have taken any form of ACCUTANE A acid or ROACCUTANE A acid in the past six months. This treatment will make the skin more sensitive to laceration, trauma and irritant substances.
    3Those who take anticoagulant drugs include those who take a large amount of aspirin, the degree of which cannot be stopped at least one week before the course of treatment so as to facilitate the drug components to be discharged out of the body.
    4 For those taking photosensitizers or drugs, please ref er to the instructions in the medicine box. If it indicates that there may be photo- allergic reaction, photo-toxic reaction or sunlight should be avoided after taking the medicine, please do not use the instrument.

  7. Please keep the instrument out of the reach of children. Minors and children under 14 years old are not recommended to use it. The instrument has not been studied in children’s population, which may lead to unpredictable effects.

  8. After sunbathing or using a sun bed, and those using non-tanning products are not recommended to use imme-ately. If you are not sure whether your skin is tanned or sunburned, we recommend to do a skin sensitivity test and wait for 24 hours.

  9. Tattooed areas with dark brown and black spots do not use directly, which may absorb a large amount of light energy and cause skin discomfort.

  10. It is forbidden to use around the eyes, near the eyebrows, on the nostrils, ears, neck, nipples, genitals or around the anus. These parts are sensitive and vulnerable

  11. It is not recommended to use in areas where hair regrowth is desired because the depilation effect lasts a long time. It is not recommended for patients with light allergy or light allergy history. If there is a history of skin cancer or potential malignant skin tumor, it is not recommended. Hemorrhoids, psoriasis, eczema, sunburn, herpes simplex, wounds or rashes are prohibited. The above situation will make the skin susceptible to light allergy and increase the probability of skin discomfort.

  12. Don’t leave the instrument in the same position for too long, or leave light at the same position for many times, which may generate too much heat and make skin uncomfortable.

  13. Sensitive and delicate skin will show a little red after use, which is a normal phenomenon and will disappear within 48 hours. Users need not worry too much and can contact customer service in time for any operation questions. When using the instrument, please do not cover the vent. The vent is used to cool the instrument. Covering the vent may cause overheating of the insttument and enter the automatic protection program.

  14. The instrument must not be affected with damp or water. It is forbidden to use the instrument when showering. It is forbidden to place the instrument beside the bathtub or sink. It is forbidden to use the instrument when the plug or power line is damaged. If there is any signal indicating that any part is damaged, please stop using the instrument. It is forbidden to open the protective cover or disassemble the instrument without permission, touch the internal parts, nor dismantle nor repair the instrument without permission. Always keep

Use and Operation Method

4.1 Preparation for use

  1. Please remove the hair on the skin surface first, and do a good job of skin pre-treatment, so that the hair under the skin surface can fully absorb the light source and ensure the effect of the treatment. If the hair does not exceed 2mm, it may not need to be shaved.
  2. Clean the skin and make sure its surface is free of any hair, completely dry and free of any oily substances. Before using the depilator, it is strictly prohibited to apply products such as condensing agent nor aloe gel,

4.2 Use steps

  1. Please remove the hair on the surface of the skin first. After wetting the hair, use the wet scraping method,
    Do a good job of skin pre-treatment, which can make the hair below the skin surface absorb the light source and ensure the effect of curative effect. If the hair does not exceed 2mm, it can not be

  2. Clean the skin and make sure there is no hair, dry and oily substances on the surface. Do not apply condensing agent before using photon hair remover. 7

  3. please clean the head filter of the machine with a soft cloth first.

  4. before depilation with this instrument, please wet the hair first and then scrape it with a hair scraper.

  5. connect the power adapter and the instrument circuit is normal.

  6. press and hold the “power on key” until the display is turned on. The screen lights up, the snowflake displays, and the screen displays the gear (the default gear).

  7. press the power switch to adjust the gear. By default, the freezing point is automatically turned on, and the two keys (power on key and light out key) can be pressed for 3 seconds at the same time to tum off , and vice versa Ready (the first flash is bright, please wear goggles to reduce eye discomfort.)

  8. please wear the sunglasses provided by the manufacturer to reduce the glare caused by the flash.

  9. press the depilator vertically on the skin at 90 ° to ensure that the skin is in full contact. The skin sensing symbol appears on the screen. At this time, the flash of the instrument is ready.
    (when the hair removal instrument is used for the first time, there will be a “micro current” feeling due to skin discomfort, which is a normal reaction of the human body and not caused by machine leakage).

  10. after the machine is attached to the skin, gently press the “flash button” of the instrument, and the instrument will emit a flash accompanied by a clear “crackling sound”. At this time, you will feel the warm feeling generated by the flash synchronously (if the temperature is too high, it means that the gear you have selected is too high, and it is recommended to start from the first gear).

  11. after using the instrument to send out a flash, replace the depilation part. When the energy is ready, repeat the above steps to depilate the selected part.

  12. use the first gear to test the skin. If there is no adverse reaction after 24 hours, the energy gear can be adjusted through “power on key”. The energy gear is divided into 6 gears.

  13. follow the above steps to depilate the selected part. One depilation treatment course is generally polished three times. Take off the whole body for the second time and the third time.

  14. please flash as close as possible to the previous flashing part, so as to fully deal with the required part.

  15. after use, please press and hold the “power on key” to shut down the machine and cut off the power supply. Finally,(gear display flashes 10 times) clean the head and fuselage.

There are two treatment modes: [manual flash] and [automatic flash], which are convenient for you to use on different body parts: -[manual flash] mode is suitable for small areas or bending parts, such as knees and armpits. Just press the flash button to send out a flash. -[auto flash] mode is convenient for large areas such as legs. Long press the flash button for 3-5 seconds, and when the cycle sign appears on the display screen, slide the instrument along the skin to automatically flash.
12.Efficacy cycle reference table
♦ Week 1-4 2-3 times a week
More than 75% gross hair starts to fall off naturally
♦ Week 5-6 2 times a week
Newborn hair fall off and suppress Growth
♦ Week7-8
1 time per week Hair thinning and less, No rebound
♦  Week8
1-2 times a week according to hair growth
Selective use (use again when hair grows out until no hair grows any longer)
♦ One hair removal treatment is three times of irradiation. The second and the third time should be done after the whole hair removal parts are covered the first time. Avoid shooting the same place three times in succession.
♦ The higher the gear position, the better the effect. In the early stage, it is recommended to use 1 gear first. After the skin is adapted, use 2-4 blocks.
After the skin is adjusted, you can choose to use 5th gear. The time between treatments can be based on individual hair growth rate. The situation of various parts of the body varies too.
4.3 Skin sensitivity test
Before using for the first time or after using it after sunscreen, please do the skin sensitivity test on each treatment site, which is a necessary step. The purpose is to check the skin’s response to the course of treatment and determine the gear position suitable for each individual.
4.3.1. Select the low gear 1 or 2
4.3.2. Follow the above methods of operation and pay attention to the contraindications; select the skin area to operate.
4.3.3. Check the skin reaction after 30 minutes
4.3.4. If the test site is normal, you can continue to use it. If the skin is red and swollen, please test it again after 24 hours.
4 .4 End of use

  1. The skin may have a slight redness or tingling or warm feeling. These reactions are completely harmless and will soon disappear.
  2. You can apply lotion, cream and fragrance to the treatment area without any worries. If the skin is stinging or red and swollen, please wait and use body lotion, moisturizer, or cosmetics after these conditions disappear. If you feel tingling after the application, please wash them off with water.

4. 5 Clean and save
Please tum off the power of the device, remove the plug, and let the instrument cool down. Soak the clean soft cloth with a little water and use it to clean the filter and skin contact surface, then place the instrument at temperature 0-60 degree in dry place with no dust.

Problem Checking and Solving

This part outlines the most common problems encountered with this instrument. If you can’t use the following information to solve the problem, please contact Customer Service Center.

Problems Checking

Problems| Possible causes| Solution
No display| Power cord not connected well| Reconnect the power cord
No shining light| The instrument is not in close touch with skin| It can only shine under the three requirements:
a. stay close to the skin
Not pressed the light button| b.Press the light button
Energy not refilled fully| c.refill the energy fully
ERROR 1 on the screen| Machine over-heated protection| Recommend shutdown and cooling for 10 minutes before restart
Shows normal but no light| Instrument running for a while, not shining for the second press| Unplug power after shutting down.
Then re-plug again.

Product Warranty

The warranty period for the whole machine is one year from the date of purchase of the instrument. If one of the following conditions occurs within one year, even during the warranty period, it can not be processed by warranty. If you need repair, please contact customer service.

  1. Damages caused by not following the requirements of the product manual;
  2. Damages caused by the misuse in the middle of the process (washing, soaking, etc.);
  3. Damages caused by use beyond the permitted environment (such as high temperature, corrosion, etc.);
  4. Damages caused by abnormal external force (fall, squeeze, impact, etc.);
  5. Damages caused by natural force majeure (fire, flood, lightning, etc.);
  6. Damages caused by privately use non-manufacturer accessories and extensions;
    Listed above, if any changes take place, the company’s newly formulated relevant regulations and national updated laws shall prevail.

Customer Service

Dear customer, first of all, thank you very much for choosing our hair removal equipment. We have the opportunity to provide you with the highest quality service to make you more satisfied. Please read this manual carefully after purchasing. If you have any questions, please communicate with us in time, we will do our best to help you.

  1. If you have any use problems, please contact us, we will provide timely sales services to solve your use doubts;
  2. If the product has quality problems and cannot be used normally, please contact us in time for after-sales service. We provide worry-free replacement services.

Applicable skin tone and body hair color

Jitesy KT09 IPL Hair Removal Device - Hair Color

Due to the way the IPL technology itself works.
IPL isn’t suitable for the darkest skin tones.
IPL is also not recommended for red, grey or very light (blonde) hair.

Jitesy Logo

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals