LANQUAD K58S55 5.8GHz Microwave Motion Sensor Owner’s Manual
- June 16, 2024
- LANQUAD
Table of Contents
- LANQUAD K58S55 5.8GHz Microwave Motion Sensor
- Product Information
- Product Usage Instructions
- Frequently Asked Questions
- Introduction
- Features And Applications
- Ordering Information
- Specification
- Pin Description
- Operation Modes And Verification Result
- Verification Result
- Installation Guide
- FCC STATEMENT
- Contact
- Documents / Resources
LANQUAD K58S55 5.8GHz Microwave Motion Sensor
Product Information
Specifications
- Product Name: K58S55 5.8GHz Microwave Motion Sensor
- Operating Frequency Range: 5.725GHz – 5.875GHz
- Transmission Power: 4.0dBm – 9.0dBm
- Power Supply: 5V – 12V DC
- Output High: 4.3V
- Output Low: 0.4V
- Current: 12mA (typical)
- Installation Height: Customizable (up to 10m)
- Detection Range: Customizable (up to 20m)
- Delay Time: Customizable (up to 5s)
- Photocell Threshold: Customizable (Lux)
- Operating Temperature: -20°C to 85°C
Features
- Supports ISM 5.8GHz frequency band
- Compact size: 19mm x 19.8mm
- Built-in anti-interference algorithm for excellent performance
- Customizable detection range, time delay, and ambient threshold
- Supports Quick-Test and Aging modes for easier verification
Pin Description
- Pin 1: RX – External input signal (customizable)
- Pin 2: GND – Ground
- Pin 3: OUT – Digital Output (customizable)
- Pin 4: Vin – PWM Power Supply
Operation Modes
- Normal Detection Mode: Power on -> Light ON for 3s (default, customizable) -> Off for 2s -> Normal detection mode
- Quick-Test Mode: Power ON and OFF for 3 times -> Light flashes 3 times -> Quick-Test mode. Delay time = 5s, regardless of photocell. Quick-Test mode lasts for 4 minutes and then the sensor turns into normal detection mode.
- Aging Mode: Power ON and OFF for 10 times -> Light flashes 5 times -> Aging mode. Light always ON, regardless of photocell, until power on again. This mode makes customer’s verification easier. Note: These modes require matching between the sensor and driver side. Refer to sales/FAE team for more information.
Product Usage Instructions
Installation
To install the K58S55 5.8GHz Microwave Motion Sensor, follow the steps below:
- Choose a suitable location for installation. The sensor can be mounted on the ceiling or wall.
- Ensure that the installation height is within the customizable range (up to 10m).
- Use appropriate mounting hardware (screws, brackets, etc.) to securely attach the sensor to the desired surface.
Customization
The K58S55 sensor offers various customizable parameters to suit your specific requirements. Follow the instructions below to customize the sensor:
- Refer to the user manual or contact the sales/FAE team for detailed information on customizing the sensor.
- Make necessary adjustments to the detection range, time delay, and ambient threshold according to your needs.
- Ensure proper matching between the sensor and driver side for the desired operation modes (Normal Detection, Quick-Test, Aging).
Usage
Once the K58S55 sensor is installed and customized, it can be used for various applications. Follow the instructions below to use the sensor:
- Connect the sensor to a compatible power supply within the specified voltage range (5V – 12V DC).
- Ensure that the power supply has a ripple of less than 100mV.
- Observe the LED light on the sensor. It will indicate the current mode of operation (Normal Detection, Quick-Test, Aging).
- Based on the desired mode, the sensor will detect motion within the specified range and generate control signals accordingly.
- Use these control signals to switch on/off lights or trigger other devices in your smart lighting, security monitoring, or intelligent control system.
Maintenance
To ensure optimal performance of the K58S55 sensor, follow the maintenance guidelines below:
- Regularly clean the sensor’s surface using a soft cloth or brush to remove any dust or debris.
- Avoid exposing the sensor to extreme temperatures or humidity.
- Check the sensor’s connections periodically to ensure they are secure and free from corrosion.
Troubleshooting
UIf you encounter any issues with the K58S55 sensor, refer to the troubleshooting guide provided in the user manual or contact the customer support team for assistance.
Frequently Asked Questions
- Q: Can I customize the detection range and time delay of the sensor?
- A: Yes, the K58S55 sensor offers customizable detection range and time delay. Refer to the user manual for instructions on how to customize these parameters.
- Q: Can I use the sensor with LED lights?
- A: Yes, the K58S55 sensor can be used with LED lights for smart lighting applications. It generates control signals to switch the lights on/off based on detected motion.
- Q: Can I use the sensor for security monitoring?
- A: Yes, the K58S55 sensor is suitable for security monitoring applications. It detects motion in the designated range and triggers appropriate actions, such as activating alarms or recording video.
- Q: How do I verify the installation height of the sensor?
- A: The installation height can be verified by referring to the provided installation height verification result. It shows the detection areas based on different mounting positions (ceiling or wall).
Introduction
K58S55 is a compact microwave sensor, which is operating at ISM 5.8GHz band. It works on the principle of the ‘Doppler effect’. If a movement in the detection zone changes the echo pattern, the sensor responds and generate control signal to switch light on. The compact size, low power consumption, customized detection distance and time delay make K58S55 ideal for scenarios of smart lighting, security monitoring, intelligent control system.
Features And Applications
Features | Applications |
---|
Support ISM 5.8GHz Size: 19*19.8mm Operating Voltage: 5-12V
Customized detection range, time delay, ambient threshold.
180°detection range when wall mount 360°detection range when ceiling mount
Built-in anti-interference algorithm. Excellent performance.
Support modes of Quick-Test and Aging. Easier for customer’s verification.
|
LED Lights
Security Monitoring; Intelligent Control System.
Ordering Information
Product Name
| ****
PCB Oil
| ****
Delay (s )
| ****
Photocell
| ****
Variance
---|---|---|---|---
PBA-K58S55
| ****
– WF
(white)
| ****
– 030
(Could be customized)
| ****
L(with) N(without)
| A B
…
(Could be customized)
Absolute Maximum Rating Note1
Parameter | Designation | Rating | Unit |
---|---|---|---|
Vin | Input Voltage | 12 | Vdc |
Topt | Operation Temperature | -20~85 | ℃ |
Tstg | Storage Temperature | -45~150 | ℃ |
ESD | Human-Body Model |
Note2
| 2| KV
Note 1: Stresses above those listed under Absolute Maximum Ratings may
cause permanent damage to the device.
Note 2: MIL-STD-883C. Human body equivalent capacitance of 100pF and
resistance of 1.5kΩ.
Specification
Parameter | MIN | TYP | MAX | Unit | Comment |
---|---|---|---|---|---|
Frequency range | 5.725 | 5.80 | 5.875 | GHz | ISM 5.8GHz |
Transmission power | 3 | dBm | |||
Power supply | 5 | 9 | 12 | V | DC |
Output High | 4.0 | 4.3 | V | ||
Output Low | 0.4 | V | |||
Current | 12 | mA | |||
Installation height Note 3 | 3 | 5 | m | ||
Detection range Note 4 | 4 | m | Could be customized | ||
Delay | 1sec ± 0.5sec to 30min ± 1min | Could be customized | |||
Photocell threshold | 10 | 20 | Lux | Could be customized | |
Operating temperature | -20 | 85 | ℃ |
Note 3: Has impact on detection range
Note 4: Measurement averaged over 360° detection range with 3m
installation height of ceiling mount
Pin Description
Note5
Pin NO. | Pin Name | Description |
---|---|---|
1 | RX | External input signal. Could be customized. |
2 | GND | Ground |
3
|
OUT
| Digital Output (could be customized)
– High/Low (1-Motion;0-Still)
– PWM
4| Vin| Power Supply
Note 5 : Pin1-Pin4 Compatible with 2.0mm/2.54mm pin
Operation Modes And Verification Result
Operation Modes
Verification Result
The module could be ceiling- or wall- mounted. The detection areas are given as below. (Variation exists due to mechanics, installing methods, etc)
- Note 6: Typical test environment,Tester: 170cm, 65kg, speed: 1m/s
- Note 7: Power supply 9V, Ripple < 100mV, Ta = 25℃.
- Note 8: The result given above is for reference. Variance exists due to test environment changes.
Installation Guide
- No inductance beneath sensor module as inductance may introduce interference with sensor.
- Keep power supply as clean as possible. 100uF capacitor is recommended on power supply side.
- Keep antenna plane at least 3mm away from nearby stuffs.
- Too big (eg, playground)or too small space (< 2m²) shall be avoided as sensor’s performance might degrade.
- No metallic stuff in front of antenna.
Revision History
Date | Comment | Revision |
---|---|---|
11/11/2023 | First Release | A |
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: This device may not cause harmful interference, and This device must accept any interference received, including interference that may cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement.
The device can be used in portable exposure condition without restriction.
Integration instructions for host product manufacturers according to KDB 996369 D03 OEMManual v01
Conditions on using Lanquad Semiconductor Co.Ltd regulatory approvals:
- Customer must ensure that its product (the“CUSTOMER Product”) is electrically identical to Lanquad Semiconductor Co.Ltd reference designs. Customer acknowledges that any modifications to Lanquad Semiconductor Co.Ltd reference designs may invalidate regulatory approvals in relation to the CUSTOMER Product, or may necessitate notifications to the relevant regulatory authorities.
- Customer is responsible for ensuring that antennas used with the product are of the same type, with same or lower gains as approved and providing antenna reports to Lanquad Semiconductor Co.Ltd.
- Customer is responsible for regression testing to accommodate changes to Lanquad Semiconductor Co.Ltd reference designs, new antennas, and portable RF exposure safety testing/approvals.
- Appropriate labels must be affixed to the CUSTOMER Product that comply with applicable regulations in all respects.
A user’s manual or instruction manual must be included with the customer product that contains the text as required by applicable law. Without limitation of the foregoing, an example (for illustration purposes only) of possible text to include is set forth below:
List of applicable FCC rules
FCC Part 15 Subpart C 15.249 & 15.207 & 15.209& 15.205
Specific operational use conditions
- Operation Frequency: 5730~5835MHz
- Number of Channel: 36 Channels
- Modulation Type: CW
- Antenna Type: PCB antenna
- Antenna Gain(Peak): 3.5 dBi (Provided by customer)
The module can be used for mobile or portable applications with a maximum 3.5dBi antenna. The host manufacturer installing this module into their product must ensure that the final composit product complies with the FCC requirements by a technical assessment or evaluation to the FCC rules, including the transmitter operation. The host manufacturer has to be aware not to provide informationto the end user regarding how to install or remove this RF module in the user’s manual of the end product which integrates this module. The end user manual shall include all required regulatory information/warning as show in this manual.
Limited module procedures
Not applicable. The module is a Single module and complies with the requirement of FCC Part 15.212.
Trace antenna designs
- Applicable.
RF exposure considerations
The device can be used in portable exposure condition without restriction and if RF exposure statement or module layout is changed, then the host product manufacturer required to take responsibility of the module through a change in FCC ID or newapplication. The FCC ID of the module cannot be used on the final product. In these circumstances, the host manufacturer will be responsible for reevaluating the end product (including the transmitter) and obtaining a separate FCC authorization.
Antennas
Antenna Specification are as follows:
- Antenna Type: PCB antenna
- Antenna Gain(Peak): 3.5 dBi (Provided by customer)
This device is intended only for host manufacturers under the following conditions: The transmitter module may not be co-located with any other transmitter or antenna; The module shall be only used with the External antenna(s) that has been originally tested and certified with this module. The antenna must be either permanently attached or employ a ‘unique’antenna coupler.
As long as the conditions above are met, further transmitter test will not be required. However, the host manufacturer is still responsible for testing their endproduct for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheralrequirements, etc.).
Label and compliance information
Host product manufacturers need to provide a physical or e-label stating “Contains FCC ID: 2BDOX-K58S55 With their finished product.
Information on test modes and additional testing requirements
- Operation Frequency: 5730~5835MHz
- Number of Channel: 36 Channels
- Modulation Type: CW
- Antenna Type: PCB antenna
- Antenna Gain(Peak): 3.5 dBi (Provided by customer)
Host manufacturer must perfom test of radiated & conducted emission and spurious emission, etcaccording to the actual test modes for a stand-alone modular transmitter in a host, as well as for multiple simultaneously transmitting modules or other transmitters in a host product. Only when all the test results of test modes comply with FCC requirements, then the end product canbe sold legally.
Additional testing, Part 15 Subpart B disclaimer
The modular transmitter is only FCC authorized for FCC Part 15 Subpart C 15.247 & 15.207 & 15.209 & 15.205and that the host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification. If the grantee markets their product as being Part 15 Subpart B compliant (when it also contains unintentional-radiator digital circuity), then the grantee shall provide a notice stating that the final host product still requires Part 15 Subpart B compliance testing with the modular transmitter installed.
Contact
Lanquad Semiconductor Co.,Ltd
- Tel: +86-25-8690 6106
- Web:www.lanquad.com
Scan
Documents / Resources
|
LANQUAD K58S55 5.8GHz Microwave Motion
Sensor
[pdf] Owner's Manual
2BDOX-K58S55, 2BDOXK58S55, K58S55 5.8GHz Microwave Motion Sensor, K58S55,
5.8GHz Microwave Motion Sensor, Microwave Motion Sensor, Motion Sensor, Sensor
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>