OCEANWELL 236J760 Manual Push Button and Cistern User Manual
- June 15, 2024
- OCEANWELL
Table of Contents
- OCEANWELL 236J760 Manual Push Button and Cistern User Manual
- Congratulations on your purchase
- Important information
- Accessories list
- Parts list
- Cistern dimensions
- Technical specifications
- Installation steps
- Installation of tank
- Cutting of flush bend
- Installation of water inlet connector
- Installation with a front access panel
- Installation with a top access panel
- Installation of button
- Two different installation methods
- Installation of button box
- 8. Installation of toilet
- Trouble Shooting
- Maintenance
- Inlet valve adjustment
- Inlet valve washer cleaning
- Flush valve removal and adjustment
- Push button operation failure
- Cleaning
- Read More About This Manual & Download PDF:
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OCEANWELL 236J760 Manual Push Button and Cistern User Manual
Please note: Image is for illustrative purposes only and may differ slightly to the actual product
Congratulations on your purchase
And welcome to our growing gang of savvy shoppers
We’re on a mission to bring you extraordinary bathroom products, for less.
From modern to traditional style ceramics, plus the gorgeous fixtures,
fittings and furniture to match. So, you can fall in love with your space
every single day.
As one of the UK’s largest independent bathroom stores, we’ve received
countless awards; including the National Business Awards UK, the Digital
Entrepreneur Awards and being placed on The Sunday Times Fast Track 100.
We hope your new product goes above and beyond your expectations. However,
should any problems occur, please: + log in to your account and contact our
customer services team via your self-serve portal —
betterbathrooms.com/CustomerAccount/Login + contact us via
betterbathrooms.com/content/contact-us
Important information
- Please read these instructions thoroughly and retain for future reference.
- Manufactured to BS EN14055 WC and urinal cisterns.
- Allinstallation work must be carried out to comply with the Water BylawRegulations.
- The installation should be designed to allow access for maintenance.
Accessories list
Parts list
Cistern dimensions
Technical specifications
Installation steps
- Installation of wall bracket
Mark fixing points of the wall bracket
Drill holeswsing a 8mm dril bit (not supplied) and insert wall plugs. (Notg: Before drilling always check
Slightly adjust the height of the wil bracket to horizontal position and lock it tightly
Installation of tank
Hook the cistern tank onto the bracket via the slots located on the rear of the tank
Slide the tank so that it is central with the unit space
Cutting of flush bend
Cut the flush bend to size and attach to the cistern, using the appropriate installed in a horizontal fittings. Ensure alignment to pan from cistern tank is square both vertically position to avoid water 4 and horizontally to allow seal to function correctly leakage
Installation of water inlet connector
Installation with a front access panel
Installation with a top access panel
Installation of button
Notice: The push button can be installed on the top and front panel of the vanity as shown picture except the square marked areas due to the space limitation.
Two different installation methods
Installation of button box
8. Installation of toilet
Trouble Shooting
For all troubleshooting solutions, please refer to the Maintenance section. Insufficient or too much water entering the cistern tank
-
Adjust the inlet valve using the adjustment screw.
Water filling into the cistern slowly -
If the water flows into the cistern slowly, the washer on the inlet valve could be blocked and mayrequire cleaning.
-
Remove and run under warm water and clean using a small brush to remove any blockage, if thisdoes not resolve the issue, check the water supply to the cistemn.
-
. If this is running freely, replace the inlet valve.
Tank fills correctly but insufficient water leaving the tank -
Adjust the flush valve volume.
Water running into the pan continually after flushing -
Establish if the water level in the cistem is reaching the overflow on the syphon, if yes, replace the inlet valve. If it doesn’t, replace the upper section of the syphon.
Maintenance
For all maintenance measures below, you will need to gain access to the
cistern tank by removing panels/tops on your WC unit, (this access will differ
depending on your WC unit), and for the water supply to be turned off
Once you have gained access, remove the screws in the tank face/lid and this
will release the second section of the face/lid by unclipping from the tank.
Inlet valve adjustment
Twist the adjustment screw as shown in the direction required.
Inlet valve washer cleaning
- Unscrew the washer section from the inlet valve .
- Place the washer under warm running water and brush to remove any blockage.
- Then replace and tighten back into position.
Flush valve removal and adjustment
The flush valve is made of two parts, the bottom section which is secured to
the cistern tank and the upper section which can twist and pull away from the
bottom section.
During this maintenance the bottom section can remain in position
To adjust the volume of water leaving the tank, move the slider as shown. If you need to remove the flush valve to check the washer or remove the washer for cleaning, take the flush valve out and take the washer down as the process showed below.
Push button operation failure
- Take the button down as the steps below, normally press the half flush & full flush, observe whether the button can bounce back or not. If not, please replace the button.
Cleaning
To maintain the surface of the push button surface, wipe with a clean damp
cloth and wipe dry, do not use any abrasive cleaning agents or materials.
If any harsh chemicals come into contact with the surface of the product,
rinse and wipe clean immediately.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>