Riobel TRU13W1LM Wall Mounted Thermostatic Trim Instruction Manual

June 15, 2024
Riobel

Riobel TRU13W1LM Wall Mounted Thermostatic Trim

Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-
product

( Note: This is the trim only. Order 1005N, 3/4″ thermostatic rough valve to complete)

PARTS AND TOOLS

HELPFUL TOOLS

Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-1

  • For safety and ease of installation, the use of these helpful tools is recommended.

Parts List

Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-2

  • A. Valve Body Sleeve
  • B. Double-Sided Gasket
  • C. Escutcheon
  • D. Trim Ring Extension, O-Ring, & Trim Ring
  • E. Anti-Scald Ring
  • F. Handle Assembly
  • G. Decorative Handle Cap & Screw

Note: Extension kit is available. Call customer service or refer to the exploded parts page.

CAUTION:  TIPS FOR REMOVAL OF OLD FAUCET:

Always turn water supply OFF before removing existing faucet or disassembling the valve. Open faucet handle to relieve water pressure and ensure that complete water shut-off has been accomplished.

Icon Legend

Installation Instructions

Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-4

  1. Remove and discard valve body dust cover to begin trim installation.
  2. Install Valve Body Sleeve (A) onto valve body.Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-5
  3. Install Double-Sided Gasket (B) onto back of Escutcheon (C) as shown.
  4. Install both Escutcheon (C) and Gasket (B) over valve onto wall surface.Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-6.
  5. Install Trim Ring Extension, O-Ring, and Trim Ring assembly (D) onto Escutcheon (C). Extension kits are available. Refer to the exploded parts page or call customer service
  6. Install Anti-Scald Ring (E) onto valve body threads.
    • NOTE: Set water temperature to 100°F before installing the handle assembly.Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-7
  7. Ensure red dot is visible and at top of Anti-Scald Ring (E).
  8. Take the Handle Assembly (F) and remove the Decorative Handle Cap and Screw (G). Install the Handle Assembly (F) onto the cartridge.Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-8
  9. Insert and tighten the Decorative Handle Cap Screw (G).
  10. Install the Decorative Handle Cap (G) onto the Handle Assembly.Riobel-TRU13W1LM-Wall-Mounted-Thermostatic-Trim-fig-9
  11. Pull Handle (F) and turn clockwise and counter-clockwise to test water temperature.
  12. Installation is complete.

Contacts

For warranty or additional information, contact:

US Customers

WESTERN CANADA

ONTARIO

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Riobel User Manuals

Related Manuals