Product Information

Specifications

  • Product   Name: Alkaline Water Undersink Faucet
  • Model: IVYEL PL-MAX

Installation Precautions

Before installing the Alkaline Water Undersink Faucet, please take note of the following precautions:

  • Use tap water as the source of water. Do not use underground water, polluted water, or water with high hardness.
  • Avoid using warm water as the source of water.
  • Do not use water unsuitable for drinking based on the Waterworks Law.

Precautions While Using

While using the Alkaline Water Undersink Faucet, please keep in mind the following precautions:

  • Always clean the power plug before use and ensure it is free from any remains or dust.
  • If the power cable or power plug is damaged, or if the outlet is loose and can be shaken easily, stop using it and contact the maintenance service.
  • Avoid bending, damaging, modifying, pulling, or twisting the electric cord to prevent electric shock, short circuit, or fire.
  • Do not pull or insert the power plug with wet hands to avoid the risk of electrocution.
  • Ensure that the outlet used is rated higher than 10A to prevent fire due to overheating.
  • Always unplug the power plug when repairing or inspecting the product or when exchanging parts to avoid the risk of electrocution.
  • Avoid connecting the device directly with warm water above 30 degrees Celsius, as it may cause malfunction or accidents.
  • Do not use water with high hardness or water that is not suitable for drinking.

Name of Each Part (Main body)

The Alkaline Water Undersink Faucet consists of the following main parts:

  • [Main body part 1]
  • [Main body part 2]
  • [Main body part 3]

Name of Each Part (FAUCET)

The faucet of the Alkaline Water Undersink Faucet is comprised of the following parts:

  • [FAUCET part 1]
  • [FAUCET part 2]
  • [FAUCET part 3]

Component Parts (Faucet)

The faucet of the Alkaline Water Undersink Faucet is composed of the following components:

  • [Faucet component 1]
  • [Faucet component 2]
  • [Faucet component 3]

How to Use

To use the Alkaline Water Undersink Faucet, follow these steps:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

Setting Volume

To set the volume of water from the faucet, follow these instructions:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

pH Level Adjustment

To adjust the pH level of the water, please follow these steps:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

Usage Environment and Condition

The Alkaline Water Undersink Faucet can be used in the following environments and conditions:

  • [Environment/Condition 1]
  • [Environment/Condition 2]
  • [Environment/Condition 3]

Filter Configuration

The Alkaline Water Undersink Faucet has a filter configuration that consists of the following components:

  • [Filter component 1]
  • [Filter component 2]
  • [Filter component 3]

Filter Replacement

To replace the filter of the Alkaline Water Undersink Faucet, follow these steps:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

Product Usage Method

The Alkaline Water Undersink Faucet can be used by following these instructions:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

pH Concentration

For optimal pH concentration, please follow these guidelines:

  • [Guideline 1]
  • [Guideline 2]
  • [Guideline 3]

Installation Preparation

Before installation, make sure to prepare the following:

  • [Preparation item 1]
  • [Preparation item 2]
  • [Preparation item 3]

Installation

To install the Alkaline Water Undersink Faucet, please follow these steps:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

Installation Structure

The installation structure of the Alkaline Water Undersink Faucet is as follows:

  • [Installation structure description]

Fuse Change

If you need to change the fuse of the Alkaline Water Undersink Faucet, please follow these instructions:

  1. [Step 1]
  2. [Step 2]
  3. [Step 3]

Troubleshooting

If you encounter any issues with the Alkaline Water Undersink Faucet, refer to the troubleshooting guide provided by the user manual.

Specifications

The specifications of the Alkaline Water Undersink Faucet are as follows:

  • [Specification 1]
  • [Specification 2]
  • [Specification 3]

FAQ

Here are some frequently asked questions about the Alkaline Water Undersink Faucet:

  1. [FAQ 1]
  2. [FAQ 2]
  3. [FAQ 3]

Electricity Safety Information

  • Please follow the following instructions below as they are there to prevent any unexpected risk or damage.
  • Safety-related information is divided according to the magnitude of the urgency of the risk and the expected loss.
  • If the instructions are not followed, death or serious injury is possible
  • If the instructions are not followed, significant physical or material harm is possible
  • If the instructions are not followed, minor physical or material harm is possible
  • This symbol represents the operations that may be dangerous and the need for attention
  • When this symbol is present, instructions must be followed carefully to avoid any risk

Cause of electric shock and fire

  • Always clean the power plug before using it by wiping off any remains or dust on it. If either the power cable or the power plug is damaged or if the outlet is loose and can be shaken easily, stop using it and call the maintenance service.
  • An electric shock or short circuit could cause a fire.

Do not bend the electric cord

  • Do not damage, modify, bend, pull, or twist the electric cord.
  • It may cause an electric shock, short circuit, and or cause fire.

Cause of electrocution

  • Do not pull or insert a power plug with wet hands. It may cause electrocution

Use of the correct outlet

  • Please only use an outlet that is rated higher than 10A. Octopus wiring may cause fire due to overheating

When repairing product

  • Unplug the power plug when repairing or inspecting a product or when exchanging parts. It may cause electrocution

Do not use warm water!

  • Do not connect the device directly with warm water (greater than 30℃).
  • It may cause malfunction or accident.
  • Do not use water with high hardness.
  • Do not use water that is not suitable for drinking

Installation Precautions

Tap water as a source of water

  • It is recommended to use tap water as the source of water.
  • Do not use underground water,  polluted water, and water with high  hardness as source water
  • Do not use warm water as the source of water
  • Do not use water unsuitable for drinking  (Unsuitable source water based on Waterworks Law)

Prohibition of arbitrary disassembly or renovation

  • Do not use the power cord after arbitrarily disassembling or renovating it.
  • Do not arbitrarily disassemble or renovate the product, it could become the cause of electric shock or fire

Avoid installing on sloped and shaky areas

  • Do not install the product in sloped areas.
  • Do not apply excess strength or force on the product.
  • Please install the main unit on a leveled surface.
  • Do not install the product in sloped or shaky areas.
  • It may cause damage when dropped or due to collision

Cause of electrocution and short circuit

  • Do not use it in moist areas such as a bathroom.
  • Do not spray water on the product or clean the product with water.
  • It may cause electrocution and short-circuit

Do not bend the hose

  • Make sure the water hose doesn’t get tangled or bent, it could become the cause of leakage or short circuit.

Avoid heated area

  • Do not install near heating equipment such as a stove or electric heater.
  • Do not install in direct contact with fire or exposed to direct sunlight If may cause malfunction or fire.

Precautions While Using

  • Closely supervise children when using the product

In case of water shortage

  • Please unplug the power cord in case of water shortage.
  • It could become the cause of product malfunction.

Prohibition of any impact on the product

  • Do not assert any excessive shock to the product.
  • It could become the cause of electric shock or product malfunction

No movement of the product while operating

  • Please do not move the product while it is still operating.
  • Do not tilt the product over 45 degrees while moving the product.
  • It could become the cause of product malfunction.

Precautions While Using

  • Do not use as a supply of water for fish
  • Do not use alkaline water or acidic water as supply water for fish tank with goldfish, tropical fish, etc

Do not insert any sharp objects

  • Do not insert any sharp wires or drivers into the product. It could become the cause of electric shock or product malfunction.

When cleaning (electrocution, fire)

  • When cleaning, do not use benzene, thinner, cleanser, or pesticide.
  • Do not place the bowl with water, drug, food, or small metal on top of the product.
  • If it enters inside the product, it may cause electrocution, fire, or malfunction.
  • When disposing of any appliances or water filters, please follow the specified procedure.
  • It becomes the cause of environmental pollution
  • When installing parts, please use the parts provided by our own company. (Water valves, water hoses, water filters, etc.)
  • Otherwise, it could become the cause of leakage or product malfunction.
  • When replacing the water filter, please only use the filter from our own company
  • It could become the cause of abnormality of water quality or taste.
  • Do not install the product in locations where there is a risk of freezing in winter.
  • The appliance is not to be used by persons (including children) with reduced physical, sensory, or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction
  • Children may not play with the product and should be supervised when in use.

Name of Each part (Main body)

IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-19

Name of Each Part (FAUCET)


Parts (Faucet)

Obtaining alkaline water

IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-25

  1. Touch the ALKALINE button to select the desired level (level 1~4)
  2. After choosing the desired level of alkali water, touch the on/off button to get water
  3. Press the on/off button to stop the water after getting the desired amount of alkali waterIVYEL-PL-MAX-Alkaline-Water-Machine-FIG-26
  4. Touch the Acidic button to select the desired level (level 1~2)
  5. After choosing the desired level of Acidic water, touch the on/off button to get water
  6. Press the on/off button to stop the water after getting the desired amount of acidic water
  7. Touch the Purified button.
  8. Press the on/off button to get water
  9. Press the on/off button to stop the water after getting the desired amount of Purified water

Setting volume

  1. Hold the ALKALINE button for 5 seconds to enter volume set mode
  2. Choose the desired volume setting by pressing the ALKALINE button (1~6)
  3. When the desired volume level is set, after about 4 seconds to volume setting is complete.
  • <>
  • Level 1: Button sound 1
  • Level 2: Button sound 2
  • Level 3: Button sound 3
  • Level 4: Button sound 4 + Announcement
  • Level 5 : Button sound 2 + Announcement2 (default setting)
  • Level 6: Button sound 3 + Announcement3
  • Level 7 : Button sound 1 + Announcement1 + Melody 1
  • Level 8 : Button sound 3 + Announcement2 + Melody 2
  • Level 9 : Button sound 3 + Announcement3 + Melody 3

pH level adjustment

  1. Touch the Alkaline key and the Acidic key at the same time for 3 seconds.
  2. With a Button sound, the set “LE Mode” is displayed.
    • [ LE MODE L↔E↔4 Repetitive Lighting ]
    • At this time, numbers are displayed in setup value.
  3. Set the desired value with the Menu Value buttonIVYEL-PL-MAX-Alkaline-Water-Machine-FIG-30
    • pH level adjustment (Level 1~7)
    • Level 1: Low pH ~ Level 7: High pH The number displayed on the screen indicates the set level.
  4. How to LE Mode release When touching “ON/OFF”

Usage environment and condition

  1. Do not use source water unsuitable by Waterworks Law standards.
  2. Do not use it in a place with high temperatures such as the bathroom.
  3. Do not use it in a place with high moisture or temperature.
  4. Do not use it in chemical drug storage or area-generating gas.
  5. Do not use in places affected by air including air pressure, wind, sunlight, salt, etc.
  6. Please use it in a stable location without a slope.
  7. Do not use in place with low water pressure (below 14.2psi) and source water quantity (under 1ℓ/min).
  8. Usage condition
  • Temperature: +5℃ ~ +50 ℃
  • Moisture: ±70%
  • Air pressure: 1013hpa ~ 877hpa

Filter Configuration

Compound filter (lifespan: 6 months) Filter material name and country of origin

  1. High-density FELT film
  2. Carbon block filter
  3. Granular activated carbon filter
  4. Sediment filter
  5. Non-woven cloth filter
  6. Antibacterial ceramic
  7. Super ceramic
  8. Anion ceramic
  9. Calcium (chlorine remove bowl)
  10. High-density FELT film

Filter Replacement

  • To drink clean water, exchange the filter regularly according to the filter exchange period. Please replace it every 6 months or 1000 gallons of use, whichever comes first.
  • Filter exchange period may differ depending on usage amount, water quality, and water pressure.
  • If you use more water, the filter will have to be replaced sooner. Even if you use less water, there is a risk of bacterial growth from impurities trapped during the usage period. Therefore, a timer is set to remind you to replace the filter 6 months after the initial filter replacement.
  • Even if the filter exchange icon does not operate, exchange in any of the following cases.
  • When there is a smell or odd taste Exchange filter when the icon telling filter exchange on the display unit flashes.
  • When it is time to replace the filter, an alarm alerts you every time you use water, followed by the flashing of the sign “filter” on the faucet and an audio announcement saying, “Please replace the filter.” Even if the volume is muted, this audio announcement will be announced when it’s time to replace the filter.
  • After the filter replacement alert comes on, we recommend that you replace the filter within a week. You can continue to use the water as usual without any issues during this period. It is safe to drink and utilize normally.
  • After replacing the filter, it is required to do a filter reset.

Resetting the filter

  1. In standby mode HoId the PURIFIED button for 5 seconds to reset the filter
  2. sound“dding” with fiIter reset is complete, the filter will stop blinking.
  • It is normal for black water to come out from the new filter due to the activated carbon.
  • After replacing the filter, please run purified water for about 3 minutes before use. After 3 minutes, if black water continues to come out, please keep running the water until clear water comes out.
  • If water does not come out after replacing the filter, please try running it several times as it may be in the process of priming the water.
  • Filters may be purchased on our website: Ivyelshop.com

Replacing Compound FilterIVYEL-PL-MAX-Alkaline-Water-Machine-
FIG-34

Product Usage Method, pH Concentration

pH measurement method

  • Drop 3 drops of pH measurement liquid in the container and fill 10cc with water to be measured. Shake 2~3 times and color changes.
  • Compare color with colorimetric table and read the color’ value to complete measurement.

pH concentration color table

  • Do not put pH-measured water into the eye or drink it.
  • Seal pH-measured water and store it in a place away from children’s hands.
  • Do not place near fire. It may cause fire

Storage and management method after usage

  1. Make sure the power is off when moving the unit.
  2. When cleaning, do not let water enter inside the main unit.
  3. Do not block output or bend, twist, or press the hose.
  4. Use a smooth cloth to lightly wipe the surface of the main unit.
  5. Do not store in hot, moist places.

Installation

How to cut water tubing

  • When cutting the hose Cut at right angles without tilting
How to Connect and Disconnect Push Fittings

IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-38

  • If you press the convex protrusion of the fitting with your fingernail or a screwdriver and pull the hose, it will detach.
  • Push the hose all the way into the fitting (about 2mm) and connect it.

Preparation before Installation

  • Check all the components of the product. 30mm hole cutter, power drill, wrench, etc.

Precautions before installation

  • Sink top thickness (0.4~1” thickness is possible).
  • Sinkhole drilling (Need a 1-1/4” hole).
  • When installing natural marble, use a special hole cutter for turning and lock the main valve before installation.

Alkaline Water Undersink Faucet Installation Preparation

IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-39

  • Mark the position for installing the faucet on the sink and attach Use the drill to create a groove.
  • 1-1/4″ hole cutter to the electric drill. Drill the sink at a low speed.IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-40
  • To connect the main body of the ionizer, turn the connection part counterclockwise to disassemble it.
  • Note: When connecting the faucet model to the main body, no display will appear on the ionizer’s screen. All settings will be adjusted through the faucet.IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-41
  • While pressing the IN and OUT fittings on the lower part of the main body of the ionizer with your fingernail or a crosshead screwdriver, push the hose inwards, then pull it out to disconnect.
  1. To turn off the cold water valve, turn the valve clockwise.
  2. Use a wrench to disconnect the flexible hose connected to the cold water valve.IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-42
  3. Please check if there is a packing (black O-ring) inside the adapter, and connect it to the cold water valve.
  4. Connect the flexible hose(from step 2) back to the top part of the adapter.IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-43
  5. Turn the nut of the adapter counterclockwise to detach it.
  6. After cutting approximately 8 inches of the 1/4″ hose, please pass it through the detached nut. Push it all the way to connect it to the end of the adapter, and then tighten the nut securely by turning it clockwise.IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-44
  7. Please connect the 1/4″ hose connected to the main valve adapter to the IN side of the pressure-reducing valve.
    • (Arrow must point towards the machine)
  8. Cut approximately 8 inches of the 1/4″ hose connect one end to the OUT side of the pressure-reducing valve, and connect the other end to the IN side of the dust filter. (Arrow must point towards the machine)IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-45IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-47

Installation structureIVYEL-PL-MAX-Alkaline-Water-Machine-
FIG-47

Fuse Change

IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-48

The fuse is located at the upper portion of the back of the unit.

  1. The fuse can be removed if rotated counter-clockwise with a screwdriver.
  2. Insert the new fuse (3.15A)
  3. Tighten the fuse by rotating it clockwise with a screwdriver.
  • Note: When changing the fuse, please make sure to unplug the power cord first. Not doing so may cause an electric shock.

TROUBLESHOOTING

If there is ANY TROUBLE IN OPERATING this device, please read the instructions carefully and use the checklist below. Please call your local representative if there is still a problem.IVYEL-PL-MAX-Alkaline-Water-Machine-
FIG-50

Specifications

IVYEL-PL-MAX-Alkaline-Water-Machine-FIG-49

  • The above specifications are subject to change without notice for performance improvement.
  • Residential use only
  • website: Ivyelshop.com

Documents / Resources

| Ivyel IVYEL PL-MAX Alkaline Water Machine [pdf] User Manual
IVYEL PL-MAX Alkaline Water Machine, IVYEL, PL-MAX Alkaline Water Machine, Alkaline Water Machine, Water Machine, Machine
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals