ELAMOR Keyless Entry Door Lock Deadbolt - Details

Set up

After the installation is completed, it is necessary to correct the locking direction of the door lock through the “Self-test Function” of the device:

  1. Keep the door open, twist the back knob manually to extend the lock bolt and keep it extended.
  2. Press the key “ ”+“ ”+“ 9 ”+“ ” , and the device will automatically adjust the locking direction.
  3. After the adjustment is completed, the lock bolt will automatically retract and become the unlocked state, otherwise perform the above operation again.
  4. If the device enters the user, it needs to verify the master code or fingerprint before performing the “Self-test Function” .

Note:

  1. The master code is “ 123456 ” under factory default conditions. After adding master, the default code becomes invalid.
  2. If there is no master, the default code has administrator privileges.
  3. Users can set a 6-8-digit code.
  4. Users can prevent the code from being exposed to strangers by entering random numbers before and after the code, and the number of digits does not exceed 40.
  5. The “ ” key has function of locking and returning , and the “ ” key has the function of unlocking and confirming. Users can also unlock and lock by verifying fingerprint.
  6. If you enter the wrong code or fingerprint 5 times in a row, the system will be locked for 3 minutes.
    This state can be released after the time is up or the power is cut off.

Instructions(press “ ” or timeout to exit)
Add master code or fingerprint:

  1. Press “ ”+“ ”+“ 1 ”+“ ” .
    (Need to enter a master code before enter fingerprints)

  2. Verify the master code + “ ” confirm or verify the master fingerprint.

  3. Enter the master code + “ ” twice in a row or enter fingerprint 5 times.

  4. 10 master codes or fingerprint can be added, and the location number range is 001-010.

  5. The location number of the first master code or fingerprint added is 001 and so on.

Add user code or fingerprint:

  1. Press “ ”+“ ”+“ 2 ”+“ ” .
  2. Verify the master code + “ ” confirm or verify the master fingerprint.
  3. Enter the user code + “ ” twice in a row or enter fingerprint 5 times.
  4. 40 user codes or fingerprint can be added, and the location number range is 011-040.
  5. The location number of the first user code or fingerprint added is 011 and so on.

Add a one-time code:

  1. Press “ ”+“ ”+“ 3 ”+“ ” .
  2. Verify the master code + “ ” confirm or verify the master fingerprint.
  3. Enter the one-time code + “ ” twice in a row.
  4. The one-time code can only open the lock once, and the code will be automatically invalidated and deleted after use.
  5. 10 one-time codes can be added.

Delete user code (There are three ways):

  1. Press “ ”+“ ”+“ 4 ”+“ ” .

  2. Verify the master code + “ ” confirm or verify the master fingerprint.

  3. Enter the unneeded code or fingerprint + “ ” .

  4. Enter the location number of the unneeded code or fingerprint + “ ” .
    (For example, 002 represents the second master code, 012 represents the second user code)

  5. Enter “0000” + “ ” to delete all user codes or fingerprint except the master code or fingerprint.

  6. Master code or fingerprint need to be kept at least one.

  7. The newly added code and fingerprint will be filled to the front position.

Vacation mode:

  1. Press “ ”+“ ”+“ 5 ”+“ ” .
  2. Verify the master code + “ ” confirm or verify the master fingerprint.
  3. When vacation mode is enabled, no user code or fingerprint other than the master will be able to open the door until the mode is disabled.

Silent mode:

  1. Press “ ”+“ ”+“ 6 ”+“ ” .
  2. Verify the master code + “ ” confirm or verify the master fingerprint.
  3. Enable and disable silent mode.

Delayed auto-lock function:

  1. Press “ ”+“ ”+“ 8 ”+“ ” .
  2. Verify the master code + “ ” confirm or verify the master fingerprint.
  3. Enter the delay auto-lock time + “ ” .
  4. The time can be set for 5-30 seconds / input “0” + “ ” to disable the delay automatic locking function.

Self-test Function:

  1. Keep the door open, twist the back knob manually to extend the lock tongue and keep it extended.
  2. Press the “ ”+“ ”+“ 9 ”+“ ” , and the device will automatically adjust the opening direction.
  3. Verify the master code + “ ” confirm or verify the master fingerprint.
  4. After the adjustment is completed, the lock tongue will automatically retract and become the unlocked state, otherwise perform the above operation again.
  5. When the device cannot be used normally, it can be adjusted to the normal state through the “Self-test Function” .

Restore to factory default settings:
Method 1:

  1. Press and hold the reset button 5 seconds through the “ Reset-PIN ” until a long beep is heard.
  2. Release the reset button.
  3. The factory default settings are restored successfully.

Method 2:

  1. Press “ ”+“ ”+“ 0 ”+“ ” .
  2. Verify the master code + “ ” confirm or verify the master fingerprint.
  3. The factory default settings are restored successfully.

ELAMOR Keyless Entry Door Lock Deadbolt - Method

Functions

  1. Add master code: + + 1 +  Default Settings 123456
    10 master codes or fingerprint can be added, and the location number range is 001-010.
    The location number of the first master code or fingerprint added is 001 and so on.

  2. Add user code: + + 2 + Default Settings No
    40 user codes or fingerprint can be added, and the location number range is 011-040.
    The location number of the first user code or fingerprint added is 011 and so on.

  3. Add a one-time code: + + 3 + Default Settings No
    The one-time code can only open the lock once 10 one-time codes can be added.

  4. Delete user code: + + 4 + Default Settings /
    Enter the unneeded code or fingerprint + “ ” confirm.
    Enter the location number of the unneeded code or fingerprint + “ ” confirm.
    Enter “0000” + “ ” key to delete all user codes or fingerprint except the master.

  5. Vacation mode : + + 5 + Default Settings Off
    No user code or fingerprint other than the master will be able to open the door until the mode is disabled

  6. Silent mode: + + 6 + Default Settings Off
    Enable and disable silent mode.

  7. Empty

  8. Delayed auto-lock: + + 8 + Default Settings Off
    Enter the delay auto-lock time + “ ” confirm.
    The time can be set for 5-30 seconds input “0” + “ ” key to disable the delay automatic locking function

  9. Self-test Function: + + 9 + Default Settings  /
    After the installation is completed, it is necessary to correct the locking direction of the door lock through the “Self-test Function” of the device.
    When the device cannot be used normally, it can be adjusted to the normal state through the “Self-test Function”

  10. Restore to factory default settings Default Settings Above
    Press and hold the reset button 5 seconds through the “ Reset-PIN ”.
    Press “ ”+“ ”+“ 0 ”+“ ” + Verify the master code or fingerprint + “ ” confirm.