Product Information
Specifications:
- Model: BDUP2601
- Power consumption: 1/10 HP (2.5A)
- Power supply: 120V~ 60Hz
- Max. flow rate: 330 GPH
- Max. pump height: 39 ft
- Max. water temperature: 35°F
Product Usage Instructions
Safety Information:
Please read and understand the following safety instructions before using
the Transfer Pump:
- WARNING: Ensure that the pump is used in a safe and appropriate manner to prevent any potential hazards.
Installation:
-
Place the Transfer Pump in a suitable location near the water source.
-
Connect a 5/8 in. outlet hose (not included) to the outlet side of the pump (A). The outlet hose should be as short as possible and no longer than 25 ft.
-
The inlet hose (B) must reach the surface of the water source, and the outlet hose must be kept below the water level.
Powering On: -
Plug the cord of the Transfer Pump into a grounded A/C outlet that supports 115 volts and is protected by a ground-fault circuit-interrupter (GFCI).
-
If the outlet hose is restricted or raised, the pump (A) may deliver less water. Ensure that the outlet hose is not obstructed or elevated to maintain optimal performance.
Frequently Asked Questions (FAQ)
Q: What is the maximum flow rate of the Transfer Pump?
A: The maximum flow rate of the Transfer Pump is 330 gallons per hour
(GPH).
Q: Can I use a longer outlet hose than 25 ft?
A: It is recommended to use an outlet hose that is as short as possible
and does not exceed 25 ft in length.
Q: What is the maximum water temperature that the Transfer Pump can
handle?
A: The Transfer Pump can handle a maximum water temperature of 35°F.
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the product.
DANGER
-
ELECTRICAL SHOCK HAZARD.
This pump is non-submersible. Keep the motor dry at all times. Do not wash the motor. Do not immerse. Protect the motor from wet weather. Do not allow any part of cord or receptacle ends to sit in water or in damp locations. Failure to follow these warnings will result in death or serious injury and/or property damage. -
FIRE/EXPLOSION HAZARD.
Pump only clear water. Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc.
Do not use in a flammable and/or explosive atmosphere. Failure to follow these warnings could result in death or serious injury and/or property damage. -
RISK OF ELECTRIC SHOCK.
These pumps have not been investigated for use in swimming pool areas.
WARNING
-
ELECTRICAL SHOCK ALERT.
Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. -
ELECTRICAL SHOCK ALERT.
Connect this product to a properly-grounded 120 volt circuit equipped with a Ground Fault Circuit Interrupter (GFCI) device. -
ELECTRICAL SHOCK ALERT.
Do not handle pump or pump motor with wet hands or when standing on a wet or damp surface or in water. -
ELECTRICAL SHOCK ALERT.
Protect pump from extreme heat, cold and humidity. This unit is not waterproof and is not intended to be used in showers, saunas, or other potentially wet locations. The moto is designed to be used in a clean, dry location with access to an adequate supply of cooling air. Ambient temperature around the motor should not exceed 104’F (40’C). For outdoor installations, motor must be protected by a cover that does not block airflow to and a ound the motor. This unit is not weatherproof, no is it able to be submersed in water or any other liquid. Do 「not use in or near swimming pool or spa -
ELECTRICAL SHOCK ALERT.
BE CERTAIN the pump power source is disconnected before installing or servicing pump -
ELECTRICAL SHOCK ALERT.
In any installations where property damage and/or personal injury might result from an inoperative or leaking pump due to power outages, outlet hose blockage, or any other reason, a backup system(s) should be used. In order to safely use this product, familiarize yourself with this pump. -
ELECTRICAL SHOCK ALERT.
Protect electrical cord from sha「p objects, hot surfaces, oil and chemicals. Avoid kinking the co「d. Replace or repair damaged or worn cords immediately -
PERSONAL INJURY ALERT.
Pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly. Refer to troubleshooting. -
CHEMICAL ALERT.
This product contains chemicals known to the state of California to cause cancer and birth defects or other eproductive harm.
CAUTION
-
PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT
This pump operates on 120 volts. Make certain that the power source conforms to the requirements of your equipment. -
PRODUCT DAMAGE MAY RESULT
This pump is not designed to handle salt water, brine, laundry discha「ge or any other liquid that may contain caustic chemicals and/or foreign materials -
PRODUCT DAMAGE MAY RESULT
The maximum temperature of the pumped liquid must not exceed 130°F (54°C). The minimum allowable temperature is 40°F (4°C). -
PRODUCT DAMAGE MAY RESULT
Be sure the wate「 source and piping are clea「 of sand, dirt and scale. Debris will clog the pump and void the warranty. -
PRODUCT DAMAGE MAY RESULT
Failure to protect the pump and piping from freezing will cause damage and void the warranty -
PRODUCT DAMAGE MAY RESULT
Do not run pump dry. Impeller and seal damage will result. -
PERSONAL INJURY MAY RESULT
Release all pressure within the system before servicing any component. Provide a means of pressure relief for installations where the outlet hose can be shut off or obstructed. -
PROPERTY DAMAGE MAY RESULT
Drain all liquids from the system before servicing. -
PERSONAL INJURY AND/OR PROPERTY DAMAGE MAY RESULT
Secure the outlet hose before starting the pump. An unsecured outlet hose will whip, possibly causing personal injury and/or property damage. -
PERSONAL INJURY MAY RESULT
Do not touch motor while operating pump. Motor is designed to operate at high temperatures.
PACKAGE CONTENTS
PREPARATION
Before beginning installation of product, make sure all parts are present.
Compare parts with package contents list. If any part is missing or damaged,
do not attempt to assemble the product.
Estimated Installation Time: 5 minutes
No tools required for assembly.
INSTALLATION INSTRUCTIONS
NOTE: Pump (A) depends on the liquid flowing through it for lubrication. DO NOT RUN THE PUMP (A) DRY!
- Mount pump (A) solidly on a stable platform. Pump (A) should be located so that the water source is within reach of 6 ft. inlet hose (B).
- Check to be sure there is a washer in the inlet fitting of inlet hose (B). Install inlet hose (B) on the inlet side of pump (A). Make sure all connections are tight. If connections leak, pump (A) will not operate.
PRIMING AND STARTUP
-
To prime pump (A), fill the pump cavity through the outlet to wet the impeller.
-
Install a 5/8 in. outlet hose (not included) on the outlet side of pump (A). Outlet hose should be as short as possible and no longer than 25 ft.
Inlet hose (B) must reach below the surface of the water and the outlet hose must be kept above water. -
Turn on pump (A) by plugging the cord into a 115 volt, 60 Hz grounded A/C outlet protected by a ground-fault circuit-interruptor (GFCI). If the outlet hose is restricted or raised, pump (A) will deliver less water.
-
If pump (A) does not start to pump water within 30 seconds, unplug and re-check the installation and plumbing as follows.
-
Check to be sure pump (A) is located so that the water source is within reach of 6 ft. inlet hose (B).
-
Check to be sure all inlet connections are air and water- tight and inlet hose (B) is as short as possible.
-
Check to be sure inlet hose (B) is below the surface of the water source.
-
Check to be sure the outlet hose is less than 25 ft. in length and is above the surface of the outlet water.
-
Then repeat steps 1 through 3.
-
-
To reduce friction, do not coil or kink the hoses. When pumping from a well or stream, raise the inlet hose (B) a few inches off the bottom to avoid pumping in debris which can damage the pump (A).
-
This unit is shipped with a puddle vac (C) accessory which allows it to remove water from flat surfaces.
After attaching inlet hose (B) in step 2, attach the puddle vac (C) onto the end of the inlet hose (B) and place it on the surface to be pumped.
CAUTION: Before water is completely gone, unplug the pump. DO NOT RUN PUMP DRY!
CARE AND MAINTENANCE
-
Always drain pump (A) when not in use. If pump is going to be out of use for a month or longer, flush with fresh water and remove face plate cover. Using a screwdriver (not included), remove impeller.
Clean inside pump (A) cavity and apply a generous coating of petroleum jelly (not included) to the inside of the cavity and the impeller before replacing the impeller. The pump should be checked frequently for proper operation. If anything has changed since the pump was new, it should be repaired or replaced.
-
How to Replace Brushes
NOTE: Motor brushes (not included) are normal wear items and must be replaced periodically.-
Be sure pump (A) is disconnected from power source.
-
Unscrew brush cap located along the side of the motor.
Remove brush and spring and spring cover by pulling them straight out of the brush holder. -
Install new brush and spring assembly (not included), keeping the new brush curvature aligned the same as the previous brush.
-
Replace cap.
-
-
How to Replace Impeller
NOTE: Replace the impeller when it has been worn or damaged by foreign objects, improper liquid or running dry.- Remove four face plate screws, face plate and gasket.
- Remove damaged or worn impeller.
- Clean the inside of the pump cavity and remove any foreign materials that might prevent the impeller from moving easily.
- Apply petroleum jelly to the inside of the pump cavity and the outside of the new impeller (not included).
- Align the flat on the new impeller with the flat on the motor shaft. Push into place while twisting blades in a clockwise direction.
- Place new gasket on pump cavity face, align holes and replace cover. Tighten all four screws evenly and snugly.
TROUBLESHOOTING
Technical data
Model | BDUP2601 |
---|---|
Power consumption | 1/10HP(2.5A) |
Power supply | 120V~ 60Hz |
Max.flow rate | 330GPH |
Max.pump height | 39Ft |
Max.water temperature | 35 ℃ |
Amazon customer
Aliex press customer
Global: support-ae@prostormer.cn
USA: support@prostormer.cn
Europe: support-eu@prostormer.cn
Japan: support-jp@prostormer.cn
PROSTORMER Customer Support Team
Facebook Q PROSTORMER
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>