TRIYON GHE80SS Gas Water Heater User Guide
- June 13, 2024
- TRIYON
Table of Contents
- TRIYON GHE80SS Gas Water Heater
- over wives
- BEFOREYOU BEGIN Gather required additional tools
- SCAN CODE for additional information and videos
- A Successful Install STARTS HERE
- WATER CONNECTIONS
- GAS CONNECTION
- ELECTRIC CONNECTION
- FINAL STEPS
- CUSTOMER SERVICE
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
TRIYON GHE80SS Gas Water Heater
over wives
BEFOREYOU BEGIN Gather required additional tools
SCAN CODE for additional information and videos
A Successful Install STARTS HERE
INSPECT SHIPMENT Check for any damage that may have occurred during shipping or handling.
PREPARE THERMALEXPANSION TANK Make sure the thermal expansion tank is properly sized for the application and pressurized to the building static water pressure.
LOCATE NEUTRALIZERAND NEUTRALIZERROCKS Empty neutralizer rocks from bag into condensate tee. Pour 1 Cup of Water into exhaust tee to prime
WATER CONNECTIONS
Step 1, Connect the Inlet and Outlet
Four water inlet and outlet connections at the top, side and bottom for easy piping
- Two 2″ Water Connections Ports on Front
- Two 2″ Water Connections Ports on Back
- One 1-1/2″ Water Connection Port on Top
INSTALLER TIP
- Remember to fill water heater before startup
GAS CONNECTION
Step 2 , Connect the Gas Line
For best performance
- Ensure that all gas connections, regulator(s), and meter are sized properly for the BTU/h rating (See Installation Manual for charts)
- Regulator should be a minimum of 8′ from the water heater
- If installing more than one water heater, make sure each water heater has a regulator
- Check all connections and fittings for leaks
NOTE: Heaters are not field convertible from LP to Natural Gas and vice versa.
VEN TING
Step 3, Hook Up the Intake and Exhaust
For optimum performance, proper venting is essential. Here are a few tips for installation
- Calculate total equivalent feet.
- 90° and 45° elbows reduce the equivalent vent length by the these values
-
Ensure that vent runs are sloped
(1/4″ per foot rise recommended) -
Install condensate drain / loop for air intake
-
Rheem recommends long sweep elbows when
possible
Direct Vent, Vertical Vent Horizontal Intake
Direct Vent, Horizontal Vent Vertical Intake
NOTE:
For Horizontal Power Direct Vent configurations,GHE119SS/SU models will need
to have a 45 degree elbow on the intake and a 90degree elbow on th exhaust.
MINIMUM AND MAXIMUM VENT LENGTHS
POWER VENT| Max Vent Length (Eq. Ft.) Rigid Pipe Diameter
INLET MODELS| 2″ (5 CM)| 3″ (8 CM)| 4″ (10 CM)
Inlet| Outlet| Inlet| Outlet| Inlet| Outlet
GHE80SU-130(A)
GHE80SU-160(A)
| 1 (0.31 m)| 20 (6.1 m)| 1 (0.31 m)| 135 (41.1 m)| 1 (0.31 m)| 185 (56.4 m)
GHE80SU-200(A)| N/A| N/A
GHE80SU-300(A)
GHE100SU-130(A)
GHE100SU-160(A)
| 1 (0.31 m)| 20 (6.1 m)
GH100SU-200(A)| N/A| N/A
GHE100SU-250(A)
GHE100SU-300(A)
GHE100SU-350(A)
GHE100SU-400(A)
| 65 (19.8 m)| 100 (30.5 m)
GHE119SU-500(A)| 60 (18.3 m)| 150 (46.7 m)
| Min Vent Length (Eq. Ft.) Rigid Pipe Diameter
All applicable models| 1 (0.31 m)| 15 (4.6 m)| 1 (0.31 m)| 15 (4.6 m)| 1
(0.31 m)| 15 (4.6 m)
MINIMUM AND MAXIMUM VENT LENGTHS
POWER VENT| Max Vent Length (Eq. Ft.) Rigid Pipe Diameter
INLET MODELS| 2″ (5 CM)| 3″ (8 CM)| 4″ (10 CM)
Inlet| Outlet| Inlet| Outlet| Inlet| Outlet
GHE80SU-130(A)
GHE80SU-160(A)
| 1 (0.31 m)| ** 20 (6.1 m)| 1 (0.31 m)| 135 (41.1 m)| 1 (0.31 m)| 185
(56.4 m)
GHE80SU-200(A)| N/A| N/A
GHE80SU-300(A)
GHE100SU-130(A)**
GHE100SU-160(A)
| 1 (0.31 m)| 20 (6.1 m)
GH100SU-200(A)| N/A| ** N/A
GHE100SU-250(A)**
GHE100SU-300(A)
GHE100SU-350(A)
GHE100SU-400(A)
| 65 (19.8 m)| ** 100 (30.5 m)
GHE119SU-500(A)| 60 (18.3 m)| 150 (46.7 m)
| Min Vent Length (Eq.Ft.) Rigid Pipe Diameter
All applicable models**| 1 (0.31 m)| 15 (4.6 m)| 1 (0.31 m)| 15 (4.6 m)| 1
(0.31 m)| 15 (4.6 m)
ELECTRIC CONNECTION
Step 4, Connect the Electrical
To ensure proper ignition:
- Ensure all electrical connections are secure
- Use correct polarity
- Connect to a 120VAC – 50/60 Hz power supply
- Ensure water heater is properly grounded back to the main breaker box with minimum 12 gauge
- Ensure breaker is sized properly for 7 AMP servicer water heated
INSTALLER TIPS
- Connect the yellow wires from the water heater to the exhaust pressure switch
- Connect the white wires from the heater to the flue temperature sensor
FINAL STEPS
Step 5 , Complete the Setup
Once power is applied to the water heater and the ‘On’ button is pressed, the LCD will automatically begin the Startup Wizard:
- Set the Time and Date
- Schedule Hours of Operation for the business – Enables Triton to save energy and money when the business is not operating
- Connect to WiFi – Enables users to receive leak and diagnostic alerts ,usage reports and more Follow the on-screen instructions to complete setup.
CUSTOMER SERVICE
Have Questions, Need Help Trouble shooting? Get the unit’s Model and Serial Numbers ready and contact us: US 1.800.432.8373 / Canada 1.800.268.6966Be sure to have your Model and Serial Numbers before calling customer service (located on the water heater’s Rating Label)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>