Cavius ApS 2208 Mains Powered Smoke Alarm Device User Guide

June 13, 2024
Cavius ApS

Cavius ApS 2208 Mains Powered Smoke Alarm Device

Product Information

  • Product: Mains powered smoke alarm device
  • Model no.: 2208
  • Country: UK

Alarm Signals:

  • Alarm Signal 1 (— — —): Life-threatening alarms
  • Alarm Signal 2 (- – -): Non-life-threatening alarm
  • Smoke Alarm Signal: — — —
  • Heat Alarm Signal: — — —

Other Information:

  • The smoke alarm will sound the alarm signal and flash a red LED when smoke is detected.
  • The alarm signal will be transmitted to other connected alarms, which will sound the alarm after a short delay.
  • The CAVIUS Wireless Family has two different alarm signals.
  • The smoke alarm should not be painted.
  • The smoke alarm is designed for private homes.
  • The smoke alarm complies with the Radio Equipment Directive 2014/53/EU.
  • The smoke alarm operates at an RF frequency of 868 MHz with a maximum transmitted power of 20 dBm.
  • Proper disposal of the smoke alarm is required as electronic waste.
  • The user guide should be read carefully before installation and retained for future use.

Product Usage Instructions

Test Function:

  1. After installation, and at least once per quarter, test all alarms to ensure proper operation and range.
  2. Visually check the LED every week to see if it flashes correctly (every 48 seconds).
  3. To initiate a test signal, press and hold the test button on any alarm for at least 10 seconds.
  4. All connected alarms should receive the test signal within a short time, emitting a short beep and flashing the LED every 8 seconds for 2 minutes.
  5. Note that only the originating alarm’s red LED will flash for identification.

Pause/Hush Function:

  • If the smoke alarms are triggered by non-emergency situations like cooking or fireplace, they can be paused for 10 minutes.
  • To pause the alarms, press the test button on the originating smoke alarm (indicated by the flashing LED).
  • It is important to locate the source of the alarm before using the hush function to ensure it is not a life-threatening situation.

Safety Instructions:

  • The device comes with a 3V lithium battery. Handle batteries with care and keep battery-powered devices out of reach of children.
  • Do not attempt to recharge or burn the batteries.

Installation Warning:

  • To prevent injury, the smoke alarm must be permanently fixed to the ceiling or wall according to the installation instructions.
  • The installation, along with associated supply and interconnecting wiring, should be done by a professional in accordance with BS 7671:2018.

Regulatory Compliance:

  • The smoke alarm complies with Directive 2014/53/EU.
  • Full Declaration of Conformity (DoC) can be downloaded at
    www.cavius.com.

Mains powered smoke alarm device
Model no.: 2208
The smoke alarm is designed for private homes.

PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FU- TURE USE.

SAFETY INSTRUCTIONS

The device comes with a 3V lithium battery. Batteries are to be handled with care and battery powered de-vices should be kept out of reach of children. Do not try to recharge or burn the batteries.

TEST FUNCTION

After installation, and at least once per quarter, test all of your alarms to ensure they are operating cor-rectly and are within range of each other.
It is recommended to check visually every week if the LED flashes correctly (every 48sec.).

Press the test button on any alarm for at least 10 seconds.This will send out a test signal from the alarm; all other connected alarms should receive the signal within a short time. The alarms will emit a short beep and the LED will flash every 8 seconds for 2 minutes.

NOTE: Test function also transmits a weaker RF signal to ensure an optimal operation in normal con-ditions.
When the test signal is sent out, the alarms will re-spond in two ways:

  1. A single beep every 8 seconds indicates that the alarms are connected and functioning.
  2. Three short beeps every 8 seconds indicates a smoke sensor fault. The alarm should be cleaned by running the vacuum (on a low setting) around the smoke alarm chamber and tested again.
    If required this indication can be stopped early on each alarm by a short press of the test button.
    TIP: It is safe to cover the sound output holes with your finger or a cloth during the testing to minimize the sound level emitted.
    If the problem continues, please visit www.cavius.com for any trouble shooting.

NORMAL MODE

In normal mode the LED will flash every 48 seconds to show correct operation.
The green LED is on when the alarm is connected to mains power. It may take up to 1 minute to indicate that mains power has been connected.

ALARM MODE:

When the smoke is detected, the smoke alarm will go into ‘Alarm Mode’. It will sound the alarm signal and the red LED will flash.
The smoke alarm will also transmit the alarm signal to the other connected alarms, which will also sound the alarm signal after a short delay.

The CAVIUS Wireless Family have two different alarm signals:

  • Alarm signal 1 (— — —) is life threatening alarms.
  • Alarm signal 2 (- – -) is a non life threatening alarm.
  • Smoke alarm signal: — — —
  • Heat alarm signal: — — —

Please note that only the originating alarm’s red LED will flash, so it can be identified.

PAUSE/HUSH FUNCTION

If the smoke alarms are to set into a false alarm by cooking, fireplace, etc. they can be paused for 10 minutes by pressing the test button on the originating smoke alarm only (indicated by the flashing LED).
The reason for this is that it is necessary to locate the source of the alarm before using the hush function. This is to make sure that it is not a life threatening situation.

LOW BATTERY SIGNAL:
Your product has a sealed battery back-up with a 1 year life in battery mode without mains power, and up to 10 years normal life with mains.
When the battery is starting its end of life, a short beep will sound out every 48 seconds for 30 days.
Only the alarm with the low battery will sound, no oth-er connected alarms will sound.

MAINTENANCE & TROUBLE SHOOTING:

  • The smoke alarm should be vacuum cleaned once per quarter, to remove dust particles, and it can be wiped with a damp cloth. (Do not open the alarm).
  • High humidity condensing which can be resolved by drying the smoke alarm.
  • If the smoke alarm does not work when the test but-ton is pushed, the probable cause is a power failure.
  • If the problem continues, please visit www.cavius.com for any trouble shooting.

OTHER INFORMATION:

  • Do not paint the alarm.
  • Disposal: Please dispose properly at the end of life. This is electronic waste which should be recycled.
  • Complies to the Radio Equipment Directive 2014/53/EU
  • RF frequency: 868 MHz.
  • Maximum radio-frequency power transmitted: 20 dBm
  • Full DoC to 2014/53/EU (RED) can be downloaded at www.cavius.com

WARNING: Please remove dust cover after in-stallation. Smoke will not be able to reach the chamber while dust cover is in place.

  • WARNING: All alarms should be assumed as due to actual fire and the dwelling should be evacuated immediately.
  • WARNING: To prevent injury, this apparatus must be permanently fixed to the ceiling/wall in accordance with the installation instructions.
  • WARNING: Batteries shall not be exposed to exces-sive heat such as shine, fire, or the like. Note the local country regulations regarding installation.
  • WARNING: This is a mains powered unit and can be hazardous to install. We recommend that the installation, together with any associated sup-ply and interconnecting wiring, is only to be done by a professional in accordance with BS 7671:2018.
  • Hereby, Cavius declares that the radio equipment type 2208 is in compliance with Directive 2014/53/EU.
  • The full text of the EU declaration of conformity is available at the following internet address: www.cav-ius.com

The CE and RED declaration of conformity and DoP can be downloaded from: http://www.cavius.com The paper version of the DoP is available free of charge upon request.
Carrier assumes no responsibility for any errors, which may appear in this manual. Furthermore, Car-rier reserves the right to alter the hardware, software, and/or specifications detailed herein at any time with-out notice, and Carrier does not make any commit-ment to update the infor mation contained herein.
Manufacturer: Carrier Fire & Security Danmark A/S, Ellekær 9A, 2. Th, DK-2730. Made in China.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>