Safety Precautions

Be sure to read the Safety Precautions before using the POS system.

  • Before connecting, make sure the operating voltage is AC100 ~ 240V. Otherwise, you may damage the system.
  • Do not install the system in an extremely hot or cold place.
  • Avoid exposing the product in direct sunlight or in an enclosed space for a long period of time.
  • Be careful not to place the system near other high-frequency electromagnetic devices; there is a strong possibility it will lead to a system malfunction or system error.
  • Do not place heavy objects on the system.
  • Please do not allow external substances to be contaminated inside the system.
  • Do not change the motherboard’s battery by yourself. It can damage the system.
  • Before disassembling the system, disconnect all power and cables.
  • Do not remove or repair the system by yourself. We highly recommend an engineer’s assistance or an experienced technician to open the system, especially the LCD and touch panels which could be easily broken.
  • An electrical outlet is needed near the device and it should be easily accessible.
  • Risk of explosion if battery is replaced by an incorrect type. Replace only with the same type of batteries recommended by the manufacturer.
  • This device complies with the EMC (Electromagnetic Compatibility) Regulations, for business purposes. Distributors and users are advised of this matter.
  • Do not use excessive force when using or pressing the touch panel. Do not use objects with sharp edges on the touch panel.
  • Please exchange the equipment if you mistakenly sold or purchased this product.
  • Cleaning and Maintenance is relevantly necessary for POS terminal to be operated well.

POS Terminal Security Guideline
Operating System Security
System-provided and managed by the operating system’s default security settings must be configured.
Touch Screen Security Guideline
Please take special care with the touch panel as it is vulnerable to scratches.

  • Do not use excessive force when using or pressing the touch panel. Do not use objects with sharp edges on the touch panel.
  • Be careful not to spill any liquid on the screen.
  • Turn off the power switch and unplug all cables before cleaning the screen and/or the system.
  • Use a soft, clean, dry cloth for cleaning the system, and do not use chemicals or detergents.

Package Contents

imu pos ARC-HM Smart Pos System - Package Contents

  • Component images are for reference only and may vary by model and option.

Product Overview

ARC POS

I/O Port

Opening I/O cover
**** Turn off the product before connecting the input/output ports.
Press the I/O cover hook and remove it upwards.

imu pos ARC-HM Smart Pos System - cover

ARC POS I/O Ports

  1. COM 5 x 1 (RJ11 for Multi Pad)
  2. Mini DP
  3. USB x 2

imu pos ARC-HM Smart Pos System - cover1

CUBE I/O Ports

  1. DC 12V
  2. LAN
  3. USB (Type C)*
  4. USB (Type A)
  5. Mini DP
  6. Audio
  7. USB
  8. COM 1/2/3
  • Through DP Alt mode, it is possible to connect with other display devices.

Connecting product

Connecting ARC POS and CUBE PC
Connect ARC POS and CUBE using DP Cable as shown in the figure.

imu pos ARC-HM Smart Pos System - CUBE PC

Connecting Power
**** Plug the adapter’s DC cable into the system and then connect the power cord.

  1. Connect the adapter cable to DC 12V of the CUBE I/O port.
  2. Connect the power cord to the adapter.
  3. Connect the power cord to a power outlet.

imu pos ARC-HM Smart Pos System - Connecting Power

Turning on Product

** After installing all peripheral devices, turn on the power.
You can turn the power on and off in the same way on both ARC POS and CUBE.
Powering on the ARC POS**
The power button is located at the bottom right, and when you touch
the button, the power is turned on and the LED lamp lights up. Each
LED shows differing color according to operating status.

  1. LAN LED: LAN connected (RED)
  2. POWER LED: Power on (BLUE)
  3. Power button

imu pos ARC-HM Smart Pos System - Connecting Power1

Powering on the CUBE
The power button is located on the side, and when you touch the button, the power is turned on and the left and right LED lamps light up.

  1. Power button: Power on (White)
  2.  Deco LED (White)

Dimension of Product

ARC POS

imu pos ARC-HM Smart Pos System - Dimension

CUBE

imu pos ARC-HM Smart Pos System - CUBE

Specification

ARC-H(M)

Display| 12.2″ LED Backlight (1920×1200 / 16:10 Ratio)
PCAP 10 Point Multi-touch
Audio| 3W x 1, Speaker
Secondary Display| 8″ Customer Display / LED Backlight (1280×800 / 16:10 Ratio) PCAP 10 Point Multi-touch
I/O Ports| Serial(RJ11) x 1/ Mini DP x 1 / USB 2.0 x 2
Certifications| Operating : 0~40℃ at 20~90% humidity
Temperature| CE, FCC, KC
CUBE
Processor| Intel® Celeron® Processor J6412 (Finless)
Storage| Standard. 128GB (1 x M.2 2280 SATAIII) or Premium. 256GB (PCIe 3.0 NVM (option)
Memory| 4GB (1 x SODIMM DDR4 3200MHz up to 16GB)
Graphics| Intel® UHD Graphics for 10th Gen Intel® Processors
Connecting device| 802.11 b/g/n/ac Wireless & Bluetooth 5.1 combo card
I/O Ports| USB 3.0(Type A) x 1/ USB 3.2 Gen2(Type C, DP alt mode support) x 1
LAN(RJ45) x 1 / Mini DP output(Dual display support) x 1
4pin 12V DC INPUT x 1 / RS232(RJ45) x 3, USB 2.0 x 2
I/O Ports 2(Optional)| USB 2.0 x 4 / RS232(RJ45) x 2
Power| 60W / 12V DC input
OS| Windows 10 IoT Enterprise(64bit) / Windows 11(64bit)
Temperature| Operating : 0~40℃ at 20~90% humidity
Certifications| CE, FCC, KC