QAZQA 105156 Panel Light Instruction Manual

June 13, 2024
QAZQA

QAZQA 105156 Panel Light - icon 1105156 Trans DL 14 White Incl.LED CCT 105157 Trans DL 18 White Incl.LED CCT
105158 Trans DL 22 White Incl.LED CCT 105159 Trans DL 30 White Incl.LED CCT

Surface mounting installation

QAZQA 105156 Panel Light - mounting

PANEL LIGHT 105156
incl.LED QL7001145
650lm Module
450lm Lamp
6W LED
220-240V~50Hz
3000K/4000K/6500K
Selectable
CRI>80
30000 h
15000 ON/OFF| PANEL LIGHT 105157
incl.LED QL7001162
1200lm Module
960lm Lamp
12W LED
220-240V~50Hz
3000K/4000K/6500K
Selectable
CRI>80
30000 h
15000 ON/OFF
---|---
PANEL LIGHT 105158
incl.LED QL7001164
1850lm Module
1440lm Lamp
18W LED
220-240V~50Hz
3000K/4000K/6500K
Selectable
CRI>80
30000 h
15000 ON/OFF| PANEL LIGHT 105159
incl.LED QL7001165
2500lm Module
1920lm Lamp
24W LED
220-240V~50Hz
3000K/4000K/6500K
Selectable
CRI>80
30000 h
15000 ON/OFF

Turn on the power

Step 1: Draw the boreholes in the appropriate places, drill the holes and insert the dowels. Used on Suitable material such as wooden walls or lightweight walls. The metal holder with the 2 screws and the 2 washers screw on.
Step 2: Open the lid of the connection box on the back of the luminaire
Step 3: Prepare the powerless supply line according to the legal guideline. The line ends through the supplied silicone seal.
The cable according to marking connect. Insert the silicone seal into the connection box.
Step 4: Set the DIP switch to the desired light color(3K = 3000 K = warm white, 4K = 4000 K = neutral white, 6K = 6500 K= cold white).
Step 5: The lid of the connection box and the strain relief with the 4 screws fasten. Make sure that the silicone seal fits properly to the ensure splash water protection (IP44).
Step 6: Place the lamp on the metal holder and with a short right turn lock.

Overall Size

QAZQA 105156 Panel Light - Size

Recessed mounting installation

QAZQA 105156 Panel Light - installation

Step 1: Cut out the ceiling hole with the appropriate size.
Step 2: Open the lid of the connection box on the back of the luminaire.
Step 3: Prepare the powerless supply line according to the legal guideline. The line ends through the supplied silicone seal.
The cable according to marking connect. Insert the silicone seal into the connection box.
Step 4: Set the DIP switch to the desired light color(3K = 3000 K = warm white, 4K = 4000 K = neutral white, 6K = 6500 K= cold white).
Step 5: Insert the metal holder into the recess of the lamp and turn it to the right of the metal holder. The 2 spring holders in the outer opening of the insert metal holder , lift the spring slightly. The 2 spring holders on the set the required  dimension.
Step 6: Push the two springs up and insert the lamp into the ceiling hole. Make sure that the cable is not jammed.

Overall Size

QAZQA 105156 Panel Light - Size

This product contains a light source of energy efficiency class FQAZQA
105156 Panel Light - qr code

Replaceable (LED only) light source by a professional.

Replaceable control gear by a professional.

SAFETY INSTRUCTION

Please study the instruction manual and below information carefully before installing or using this product.
Please keep this user manual for further reference

  1. The luminaires may only be installed by authorized and qualified technicians according the valid regulations for electrical installation.
  2. Maintenance of the luminaires is limited to their surfaces. During maintenance no moisture can come into contact with any areas of the terminal connections or voltage control parts.
  3. The electrical supply must be switched off at the outset, preferably by means of a switch in the distribution box, before any installation, maintenance or repair work is undertaken.
  4. Exterior lighting must not be installed during rain.
  5. Take account of the minimal separation distance from other objects and the room required around the fitting.
  6. If in any doubt, consult a professional, taking local installation requirements into account. Some countries stipulate that lighting may be installed only by registered installers.
  7. Clamping screws in electrical connections must be adequately tightened. This is particularly the case with 12V low voltage conductors.
  8. When replacing a halogen lamp, wait for it to cool, for a minimum of 5 minutes.
  9. Clean with a clean, dry cloth or brush, use no solvents or abrasives. Avoid dampness on all electrical components
  10. Take account of all available technical information.
  11.  Take note of the symbols when connecting wires: N =Neutral L =Live =Earth
  12. Meaning of symbols:

For indoor use only, where direct contact with water is impossible
This icon indicates the level of water-proof and dust-proof
Protection Class I: the fitting must be earthed
Protection Class II: the fitting is doubled insulated and does not require earthing
Protection Class III: the fitting is low voltage Minimum distance from lighted objects (meters)
Only the self-shielded halogen lamp should be used with the luminaire
Strip the wire to the indicated length (mm) ;different items require different length
Connect using the specified cable; different items require different cables
The type of lamp and maximum size and wattage indicated in each lighting unit must not be exceed; different items require different kind of light sources with different bulb icons
The armature is designed to work only with the indicated voltage. Different items require different working voltage.
The luminaire can be used in combination with a dimmer
The reference light angle and light space of the luminaire

This luminaire cannot be disposed together with normal domestic waste in standard rubbish can, but you have to bring it to a staging area for electrical waste

FittinQ B.V.
Smaragdweg 52, 5527 LB Hapert, The Netherlands
www.qazqa.nl

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

QAZQA User Manuals

Related Manuals