BPL Medical Technologies ACURA V1 Volumetric Infusion Pump User Manual
- June 13, 2024
- BPL Medical Technologies
Table of Contents
ACURA V1 Volumetric Infusion Pump Experience the Relaibility VOLUMETRIC PUMP
Acura-V1 Happier Living Everyday
ACURA V1 Volumetric Infusion Pump
| Color Display
High definition 3.2” Color TFT display with user friendly interface
---|---
| Multiple Infusion Modes
In-built Flow rate, Time/volume,Dosage/Weight Infusion modes
| Double CPU
Double CPU ensures safety and reliability of infusion
| Bolus Modes
Dual bolus: Automatic and Manual along with Anti-Bolus function.
| Device Memory
2000 history records and last configuration memory
| Accurate Infusion
Precise control of the infusion rate and volume with Particular stage infusion
mode
| Automatic IV Set Calibration
Calibrated for all standard IV Infusion sets.
| Pressure Detection
3 level occlusion sensitivities setting (programmable) with picture
representation
| Alarms
Audio and visual alarms for alerts
| Fixing Clamp
Vertical & Horizontal rotatable fixation clamp
Product Specifications
Display | 3.2 inch Color TFT (240X320 Pixels) |
---|---|
IV Sets | Standard IV sets of 20d/ml and 60d/ml, with diameter 3.4-4.5mm |
Infusion Modes | Rate Mode, Time Mode, Drug/ Weight Mode, Drip Rate |
Mode(optional)
Infusion Accuracy| ≤ ±5% (after calibration)
Volume Limit| 1-9999 ml
Flow Rate Range| 0.1 ml/hr-1200m1/hr (20d/ml IV set) 0.1 ml/hr-150m1/hr
(60d/ml IV set)
BOLUS| Default 600m1/h, Values adjustable within 10-1200m1/hr (20d/ml IV set)
Default 150m1/h ,Values adjustable within 10-150mUhr (60d/ml IV set)
BOLUS Accuracy| ≤ ±5% (after calibration)
Purge Rate| 600mUhr (20d/ml IV set)
150m1/hr (60d/ml IV set)
KVO| 0.1-10ml/hr (after infusion)
Occlusion Level| 3 -level sensitivities setting
Bubble Detection| Ultrasonic with 3-level sensitivities setting, working
frequency: 2MHz±5% Effective bubble detection volume:≥0.025m1
Audio & Visual Alarm| Door open, AIR in Line, Occlusion, No operation, Power
OFF, Low Battery, Battery Err, Battery Lost, AC Lost, Sensor Err, Motor Err,
Circuit Err.,COM. Err, Overflowing etc.
Power Supply| 100V-240V AC, 50Hz/60Hz
Battery Type| Internal rechargeable Ni-MH DC12V 2000mAh
Battery Backup| 4 hours at 25m1/hr after fully recharged
Classification| Class I, CF, IPX2
Dimensions| 167mm(L) X 125mm(B) X 115mm(H) ( handgrip and clamp excluded)
Weight| 1.8Kg Approx.
Operational Conditions| Temperature: +5°C – +40°C
Relative Humidity ≤80%
Atmospheric Pressure 70KPa – 106Kpa
Storage & Transportation Conditions| Temperature: -22°C – +55°C
Relative Humidity : 10% – 90%
Atmospheric Pressure 70KPa – 106Kpa