LG LSHD3689BD Studio 36 Inch Wall Mount Chimney Hood Installation Guide
- June 12, 2024
- LG
Table of Contents
- BEFORE YOU BEGIN
- IMPORTANT SAFETY INSTRUCTION
- PRODUCT SPECIFICATIONS
- Dimensions
- PRODUCT OVERVIEW
- PLANNING THE INSTALLATION
- Accessories
- Ducting Options
- ducting Calculation Sheet
- INSTALLATION INSTRUCTIONS
- Mounting the Range Hood
- WIRING DIAGRAM
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
INSTALLATION GUIDE
HOOD
LSHD3689BD LSHD3089BD
LSHD3680ST LSHD3080ST
HCED3615S HCED3015S
Read these instructions thoroughly before installing and operating the hood.
BEFORE YOU BEGIN
IMPORTANT:
- Installer: In the interest of safety and to minimize problems, read these installation instructions completely and carefully before you begin the installation process. Leave these installation instructions with the customer.
- Customer: Keep these installation instructions for future reference and the local electrical inspector’s use.
APPLIANCE dATA PLATE
- The appliance data plate contains the model and serial number information and the electrical requirements.
- It is located inside the hood behind the filters on the back side of the chassis.
Remove the filters to view it.
All specifications subject to change without notice. LG assumes no liability for changes to specifications.
IMPORTANT SAFETY INSTRUCTION
Read and follow all instructions when using the range to prevent the risk of
fire, electric shock, personal injury, or damage. This guide does not cover
all possible conditions that may occur. Always contact your service agent or
manufacturer about problems that you do not understand.
Download this owner’s manual at: http://www.lg.com
This is the safety alert symbol. This symbol alerts you to potential hazards
that can result in property damage and/or serious bodily harm or death.
All safety messages will follow the safety alert symbol and either the word
WARNING or CAuTION. These words mean:
WARNING
- Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
- Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
WARNING
- To avoid the possibility of explosion or fire, do not store or use combustible, flammable or explosive vapors and liquids (such as gasoline) inside or in the vicinity of this or any other appliance. Also keep items that could explode, such as aerosol cans away from cooktop burners, ovens and range hoods. Do not store flammable or explosive materials in adjacent cabinets or areas.
- If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
- do not use an additional speed control device with this unit.
- To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
- Your ventilator motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off and restart, have the product serviced.
- TO REduCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJuRY TO PERSONS, OBSERVE THE FOLLOWING:
– use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
– Before servicing or cleaning unit, switch power off at service panel and lock the electrical panel door to prevent power from being switched on accidentally. When the electrical panel door cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
WARNING
- TO REduCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJuRY TO PERSONS, OBSERVE THE FOLLOWING:
– Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
– Sufficient air is needed for proper combustion and exhausting of gases through the flue(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for
Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
– When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
– Ducted fans must always be vented to the outdoors.
CAUTION
For general ventilating use only. Do not use to exhaust hazardous or explosive
materials and vapors.
GENERAL SAFETY PRECAUTIONS
To reduce the risk of fire, electric shock, serious injury or death when using
the appliance, follow basic safety precautions, including the following:
WARNING
- Do not install or operate this hood if it has been damaged, dropped, has damaged electrical wires or is not working properly. If the product is damaged when received, immediately contact the dealer or builder.
- This range hood must be installed and grounded by a qualified installer according to these installation instructions.
- Install or locate this appliance only in accordance with these installation instructions and the requirements specified by the manufacturer of the cooktop or range. Improper installation, adjustment, alteration, service or maintenance can cause serious personal injury or property damage.
- The customer should not install, repair or replace any part of the range hood unless specifically recommended in the literature accompanying it. A qualified service technician should perform all other service.
- Keep all packaging materials away from children. Plastic bags can cause suffocation.
- Do not use an extension cord or adapter plug with this appliance.
- The installer must show the customer the location of the fuse box or circuit breaker panel box so that the customer knows where and how to turn the power off.
- Before installing or servicing the range hood, switch power off at the fuse box circuit breaker and lock the electrical panel door to prevent power from being switched on accidentally. When the electrical panel cannot be locked, securely fasten a prominent warning device, such as a tag, to the electrical panel.
- Read the owner’s manual completely before using the appliance. Clean the appliance only as instructed in the owner’s manual. use only the cleaners specified.
- Do not tamper with the controls.
WARNING
-
Never allow the filter(s) to become blocked or clogged. Do not allow foreign objects, such as cigarettes or napkins, to be sucked into the hood.
-
Clean the filter(s) and all grease-laden surfaces often to prevent grease fires and maintain performance.
-
If the cooktop and range hood are near a window, use an appropriate window treatment. Avoid long drapes or other window coverings that could blow over the cooktop and hood, resulting in a fire hazard.
-
Always run the fan(s) whenever the cooktop is operating.
-
Never leave the range or cooktop unattended when a burner (or element) is in use.
Boil-overs and greasy spills may smoke and/or ignite. -
Do not leave children alone or unattended in the area where the cooktop and range hood are in use. Never allow children to sit or stand on an appliance. Do not let children play with a range, cooktop or range hood. Do not store items of interest to children above or around the cooktop, range or range hood.
-
The minimum vertical distance between the cooktop surface and the exterior part of the hood must be no less than 26″ (66 cm). The vertical distance required may be longer for the range or cooktop being used. Consult the range or cooktop installation instructions for the minimum and maximum vertical distance from the appliance being used.
-
TO Reduce THE RISK OF FIRE, use ONLY METAL Duct WORK.
PRODUCT SPECIFICATIONS
General Specifications
All Models
Fan Speeds | 5 |
---|---|
Filters | Aluminum mesh filters |
Total Connect Load | 120 VAC, 60 Hz, 4 Amp. |
Lights | 120 VAC, 8 W LED light strip |
Model Specific
Model Number| LSHd3689Bd, LSHd3680ST, HCEd3615S, LSHd3089Bd,
LSHd3080ST, HCEd3015S
---|---
Filters| 2
Weight Specifications
Model Number | Weight |
---|
LSHd3689Bd, LSHd3680ST,
HCEd3615S| 37 lb. (17 kg)
LSHd3089Bd, LSHd3080ST,
HCEd3015S| 35 lb. (16 kg)
Dimensions
Tolerances: +1/16″, -0 (1.6 mm, -0), unless otherwise stated.
NOTE
The exhaust duct(s) and electrical wiring can be connected from either the top
or the back of the hood.![LG LSHD3689BD Studio 36 Inch Wall Mount Chimney Hood
- dimensions](https://manuals.plus/wp-content/uploads/2023/08/LG-LSHD3689BD- Studio-36-Inch-Wall-Mount-Chimney-Hood-dimensions.jpg)
Overall dimensions
Model | A | B | C |
---|
LSHD3689BD,
LSHD3680ST,
HCED3615S| 36″| 15
26
/16″| 1
22
/16″
| 30″| 15 26 /16″| 1
22
/16″
PRODUCT OVERVIEW
Parts
PLANNING THE INSTALLATION
WARNING
Observe all governing codes and ordinances during planning and installation.
Contact your local building department for further information. use only duct
work deemed acceptable by state, municipal and local codes. Cabinet Layout
WARNING
To reduce the risk of personal injury caused by reaching over a hot appliance,
cabinet storage space located directly above the range should be avoided.
1 Hood | 4 Mesh Filter |
---|---|
2 Icon Touch Control Panel | 5 Side Panel |
(Only for LSHd3689Bd, LSHd3680ST,
HCEd3615S)
3 LEd Strip Light
Accessories
Included Accessories
ducting
A minimum of 6″ round duct must be used to maintain maximum air flow
efficiency. space located directly above the range should be
Always use rigid metal ducts only. Flexible ducts could restrict air flow by
up to 50%.
Also use calculation (on page 12) to compute total available duct run when
using elbows, transitions and caps.
ALWAYS, when possible, reduce the number of transitions and turns. If long
duct run is required, increase duct size from 6″ to 7″ or 8″. minimum
recirculating (B ) If turns or transitions are required, install as far away
from hood duct output and as far apart as possible.
Minimum mount height between range top to hood bottom should be no less than
26″.
Maximum mount height should be no higher than 34″.
It is important to install the hood at the proper mounting height. Mounting
the hood too low could result in heat damage and fire hazard. Mounting the
hood too high will make it hard to reach and reduce its performance and
efficiency.
If available, also refer to the range manufacturer’s height clearance
requirements and recommended hood mounting height above range.
CAUTION
DAMAGE DURING SHIPPING / INSTALLATION:
- Please fully inspect unit for damage before installation.
- If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
- If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
- If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.
Ducting Options
WARNING
Fire Hazard
- NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages.
- All exhaust must be ducted to the outside.
- use metal ductwork only.
- Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
Sample ducting Options
ducting Calculation Sheet
Maximum duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet.
Ductwork design Tips
Wherever possible, reduce the number of transitions and turns to as few sharp
angles as possible. Two staggered 45° angles are better than one 90°.
Keep turns as far away from the hood exhaust as possible, and allow as much
space between bends as possible.
For best performance, use round ducts instead of rectangular, especially when
elbows are required. If multiple elbows are used, try to keep a minimum of
24″ of straight duct between them.
Avoid “S” or “back to back” use of adjacent elbows.
In regions where the weather gets extremely cold, use thermal breaks, such as
a short section of nonmetallic duct, to avoid indoor heat loss. Locate the
break as close as possible to the outside pass-through point.
Do not use flexible metal duct.
do not use ductwork that is smaller in cross-sectional area than the
recommended types above.
Electrical Supply
This appliance requires a 120V 60Hz electrical supply, and must be connected
to an individual, properly grounded branch circuit, protected by a 15 or 20
ampere circuit breaker or time delay fuse. Wiring must be 2 wire w/ ground.
Please also refer to the Electrical Diagram label on product.
Cable Lock
A cable locking connector (not supplied) might also be required by local
codes. Check with local requirements and codes, and purchase and install
appropriate connector if necessary.
Verify the Package Contents
unpack the parts box and verify that all parts and accessories have been
included. If any item is missing or damaged, please contact the dealer
immediately. Do not install a damaged or incomplete appliance.
Make sure you have everything necessary for proper installation before
proceeding.
INSTALLATION INSTRUCTIONS
WARNING
- Do not install the range hood unless the electrical service provided meets the range hood specifications.
- Observe all governing codes and ordinances during installation. Contact your local building department for further information.
- A qualified technician must complete the installation of this built-in appliance. More than one person is required to raise the hood into place. The owner is responsible to make sure
the hood is properly installed.
Mounting the Range Hood
Mounting under a Kitchen Cabinet
CAuTION
At least two installers are required due to the weight and size of the hood.
-
Measure from range top to desired hood bottom and mark line A. (26″ minimum from range top).
-
Plumb and mark center line.
-
Mark hood height line B. (18-7/16″ from line A)
-
Mark mounting spread from center line. (8-7/8″ on line B)
-
Fasten (2) M4 x 1-1/2″ screws into studs on line B but do not tighten all the way.
NOTE
Wood blocking may need to be added behind the drywall if no studs are present. Wall anchors may also be used but check local codes for compliance. Failure to use suitable wall anchors and screws to hold the weight of the hood could result in personal injury or damage to cooking surface or counter. 6
Remove the (2) aluminum mesh filters. -
Hang hood onto the mounting screws and hand tighten each screw. (Fig A1) Secure a third M4 x 1-1/2″ screw through inside of hood into wall for extra support (Fig A2)
-
Center and attach duct cover mounting bracket to wall just below the ceiling or soffit using (2) M4 x 1″ screws.
-
Install electrical and duct work. Seal duct work with aluminum duct tape
-
Power up hood and check for leaks around duct tape.
-
Place telescopic duct covers onto hood and extend inner (top) duct cover upwards and secure to duct cover bracket using (2) M4 x 8 screws. Reinstall mesh filters.
• If using hood in recirculating mode you must secure the air diverter plate onto wall before installing duct work and duct covers. You will also need to install charcoal filters and brackets.
WIRING DIAGRAM
Models | Volts | HZ | MAX Amps |
---|
LSHD3089BD
LSHD3080ST
HCED3015S
LSHD3689BD
LSHD3680ST
HCED3615S| 120| 60| 4
References
Read User Manual Online (PDF format)