BT Inc BT-CSIV1 Intravenous Injection Training Arm User Guide
- June 12, 2024
- BT Inc
Table of Contents
BT Inc BT-CSIV1 Intravenous Injection Training Arm
Cautions
This manual describes how to use BT-CSIV Properly. Read it carefully to avoid damaging the product and injuring yourself. Pay attention to the following series of warnings.
- Use only components provided or approved by BT Inc.
- Do not disassemble, repair, or modify this product on your own.
- Keep the product away from water. If the product gets wet, do not turn it on. You could be injured by electric shock.
- Do not use the product near strong magnetic fields or high voltage power lines. The product might malfunction due to electromagnetic waves.
- Do not use the product under a condition of thunder and lightning. It can cause the product malfunction and increases the risk of electric shock.
- Do not use the product in locations with temperatures below 0 °C or above 40°C. (Operation temperature : 0°C ~ 40°(, Storage temperature : -10°C ~ 50°()
- Do not keep the product near hot places such as heaters. Transformation of product or internal damage might occur.
- Never clean the product with chemical substances such as solvent, benzene or thinner, as these may cause ignition, electric shock or cause the surface to deteriorate.
- BT Inc. can change or adjust the product specification without any notice in order to improve the product.
Components
- Left Arm manikin
- Arm manikin – 1 ea
- Skin pad (Vein tube installed) – 2ea
- Pump Driving Device
- Arm manikin mount (Volumetric pump installed) – 1 ea
- Microcomputer (installed) – 1 ea
- Volume pump Control – 1 ea
- Timer Switch – 1 ea
- One-touch fitting for connection tube – 2ea
- Accessories
- Mount – 1 ea
- Simulated blood (30ml) – 1 ea
- Plastic bottle – 1 ea
- Power source adapter (9VDC) – 1 ea
- Battery Holder – 1 ea
- Connection tube – 3ea
- Storage case – 1 ea
Features and Functions
- Arm manikin
- Skin pad (Vein tube installed)
- Blood circulation controller (Installed in Arm Manikin Manikin Mount)
- Timer switch
- Rapid blood circulation switch
- Blood IN connector
- Blood OUT connector
- Power supply connector
- Plastic bottle
- Plastic bottle IN connector
- Plastic bottle OUT connector
- Connection tube
- Mount
Installation
- Please arrange the product as the figure below.
- Either Adapter or Battery can be used as the power supply.
- Drop a few drops of simulated blood in a plastic bottle with some water and shake it.
- Installation of Skin-Pad
- Take the separate paper on the back of the Skin-Pad off.
- Insert the Skin-Pad into the gap of the back-side of the hand.
- Insert the Skin-Pad into the gap all the way to the end of Arm manikin.
- Connect the silicon tube as shown below.
User Manual
- As described in “5. Installation”, connect the power supply and connection tube.
- If you connect the power supply properly, You can hear a short buzzer sound.
- Press the Rapid Blood Circulation Switch to fill the blood vessel of Skin pad with simulated blood.
- The purpose of Rapid Blood Circulation Switch is to fill simulated blood into the empty Skin-pad rapidly.
- After you press the Timer Switch once, you can hear one buzzer sound in about two second. Then the LED lamp turns on and blood flows for 5 minutes.
- When you press the Timer Switch more than once, you can hear buzzer sounds as shown in the chart below. Then, blood will flow for several minutes as shown below.
- When you press the Timer Switch 7 times, you can hear three buzzer sounds. Then blood circulation will stop.
- When you press the Timer Switch for 3 seconds, blood circulation will stop automatically .
- After termination of the operation, you can hear the three buzzer sounds. (beep – beep — beep)
- If you want to restart, just press the Timer Switch again.
- After finishing the practice, please keep the product as described in “Chapter 7. Cleaning and Storage”.
Cleaning and Storage
- After finishing the practice, you need to disconnect the white connector from the Plastic Bottle and then press the Rapid Blood Circulation Switch to remove blood in the tube.
- Fill the bottle with clean water after expelling simulated blood. (You can reuse the simulated blood if you keep the blood in an empty container)
- Reconnect the white connector to the Plastic bottle.
- Press the Rapid Blood Circulation Switch in order to circulate the clean water to clean up the tube.
- Disconnect the white connector from the Plastic Bottle and then press the Rapid Blood Circulation Switch to remove clean water in the tube just as “(1 )”.
- After pouring the water out of the bottle, disconnect the connection tubes.
- If water leaks out from the end of connector, remove water with the tissue paper or soft cloth.
- Please keep the product carefully in the Storage case.