Brilliant Lighting 20351-05 2 Light Bathroom Mate Instruction Manual
- June 13, 2024
- Brilliant Lighting
Table of Contents
- Brilliant Lighting 20351-05 2 Light Bathroom Mate
- Product Usage Instructions
- Parts List
- For your Safety
- Introduction and Considerations
- Ventilation Requirements
- Installation
- Electrical wiring diagram
- Operation
- Specifications
- Warranty
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Brilliant Lighting 20351-05 2 Light Bathroom Mate
Product Information
NEWTON Bathroom Heaters
The NEWTON Bathroom Heaters are designed to provide instant heat to persons standing directly underneath them. The package includes a bathroom heater, a 9W R63 LED Globe Cool White, 275W heat lamps, an exterior vent, and a switch plate. This product is designed for installation in flat ceilings only and should not be mounted on a sloping ceiling or vertical wall. The heater lamps are not meant for extended periods of operation.
Product Usage Instructions
- Read all instructions before commencing installation, even if you are familiar with this type of product.
- Ensure that the fitting is installed by a qualified electrical contractor in accordance with the latest edition of AS/NZS 3000.
- Operate the product from a power source of the same voltage, frequency, and rating as indicated on the rating label.
- Install the unit above an area where “drying off” usually occurs for effective heat distribution.
- Do not install the product in a location where there is a possibility of water splashing onto the lamps.
- Locate and install the product in accordance with the requirements of AS/NZS 3000 and local building codes.
- Ensure adequate ventilation by allowing replacement air to enter the room equivalent to what is being extracted by the exhaust fan.
- If the room is airtight, ensure that there is airflow under the door or through a slightly open window.
- Ensure that there is enough space within the roof cavity for steam dissipation.
- If the roof cavity is restricted or not well ventilated, it is recommended to use duct and vent to extract steam to an outside area.
- Mount the unit at least 250mm away from vertical walls.
- Provide a minimum clearance of 100mm above the top of the unit.
- Ensure a minimum of 50mm clearance between the sides of the unit and joists, walls, or insulation.
- Follow the provided electrical wiring diagram for proper installation.
- Fix and tighten the clamps firmly to hold the flexible duct to the unit and the outer wall vent during installation.
- Ensure that the flexible duct does not obstruct or block the anti-draft stopper, as it would reduce overall airflow.
NEWTON Bathroom Heaters
20351/05 – 2 Heat Lamps
20352/05 – 4 Heat Lamps
Please read all instructions before commencing installation even if you are familiar with this type of product.
THIS FITTING MUST BE INSTALLED BY A QUALIFIED ELECTRICAL CONTRACTOR in accordance with the latest edition of AS/NZS 3000
Parts List
- Bathroom Heater
- 9W R63 LED Globe Cool White
- 275W Heat Lamps
- Ø100mm Duct 1.5m Length
- Exterior Vent
- Switch Plate
For your Safety
- To prevent electrical shock, please ensure that power is DISCONNECTED before installing.
- Be aware of the height of your installation. Refer to ‘Working at Heights “ guide from your local or State Authorities.
- This product must be used only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock, or injury to persons. If you have questions, contact the supplier or local agent.
- All wiring must be carried out by a licensed electrician in accordance with all applicable national / local codes and standards. Also check with the local council regulations regarding installation of exhaust fans.
- When cutting into the ceiling material, care must be taken to ensure you do not damage the existing ceiling structure, existing electrical wiring and other hidden utilities.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the unit.
- The lamps are extremely hot when in use. Allow all lamps to cool sufficiently before touching or replacement.
- For the purpose of avoiding any fumes leaking into your bathroom, the duct for the heater must not be laid together with ducts for air-fuelled water heaters or other open-fire appliances.
- Any alterations or additions to building wiring must be completed by a licensed electrician or person authorised by legislation to work on the fixed wiring of any electrical installation
Introduction and Considerations
- Read these instructions carefully before installing & using the product.
- Always operate this product from a power source of the same voltage, frequency and rating as indicated on rating label.
- The Infra-Red lamps are not designed to heat the entire room area, they provide instant heat to persons standing directly underneath them. Install the unit above an area where ‘drying off’ usually occurs.
- This product is designed for installation in flat ceilings only. Don’t mount on a sloping ceiling or a vertical wall.
- Heater lamps are not designed for extended periods of operation.
- Locate and install the product in accordance with the requirements of AS/NZS 3000 and local building codes.
- Do not install in a location where there is a possibility of water splashing onto the lamps.
Ventilation Requirements
- For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being extracted must be able to enter the room.
- Generally, air would be drawn under the door, or through a slightly open window. If the room is airtight, the fan will operate poorly. Air flow path should ideally pass over the steam source.
- It is also essential the there is adequate space within the roof cavity so the steam can dissipate.
- If roof cavity is restricted or not well ventilated it is recommended that duct and vent be used to extract steam to an outside area.
Clearance Requirements
- This unit must be mounted at least 250mm away from vertical walls.
- A minimum clearance of 100mm is required above the top of the unit.
- Additionally a minimum of 50mm clearance is required between the sides of unit and joists, walls or insulation.
Installation
- This unit must be mounted at least 2 metres above the floor and at least 250mm away from vertical walls.
- Remove the heat globes from the unit to prevent breakages.
- Remove the grille by releasing 4 springs in each corner of the unit.
- Ensure area behind the installation location is clear of all cables, pipes, joists or hidden utilities.
- Use the template provided to mark and cut a hole in the ceiling (Refer specifications for hole size).
- Remove rear terminal cover and connect wires as per wiring diagram on page 3. Refit terminal cover.
- Push the unit into the ceiling hole ensuring inbuilt clip fasteners hold unit securely in place.
- Additional screws can be applied around the metal flange plate to hold the unit to the ceiling.
- Secure grille with springs and insert lamps.
- Attach ducting if required to extract the air to the outer wall using 1.5 long flexible ducting, clamps and vent outlet grille provided. Fix and tighten the clamps firmly to hold the flexible duct to the unit and the outer wall vent.
- Ensure that the flexible duct, when connected to the unit doesn’t obstruct or block the anti-draft stopper, as it would reduce the overall airflow.
Electrical wiring diagram
Second heat switch not required for model with 2 heat lamps
The unit requires ‘permanent active’. The fitting is fitted with a thermal cut-out which will turn the motor (FAN) ‘ON’ when them internal temperature exceeds 80˚C.
- Double pole disconnecting device must be fitted in the circuit.
- Ensure the power is switched “OFF” at the mains before commencing installation.
- Remove the cover on the back of the enclosure to access the terminals.
- Connect wires as per electrical wiring diagram and markings adjacent to terminal block.
- Replace the cover removed earlier.
Operation
This unit uses Infrared heating lamps as a heat source. It also has an exhaust fan and an LED light.
- Heating: Switch the ‘Heat’ button ‘ON’ on the wall switch. The heat globes provide instantaneous heat from the moment they are switched ‘ON’.
- Exhaust Fan: Use the switch button ‘Fan’ to turn it ON and Off.
- LED Light: Operate the LED light independently from heat globes, using ‘Light’ On /Off switch button.
Cleaning
- Switch off the power before commencing cleaning and wait until the globes cool down.
- Regularly wipe globes and front fascia with soft cloth soaked with water or neutral detergent if required.
- Clean the exhaust fan from dust and dirt with dry or wet cloth if required.
- Clean the exhaust ducting kit and ensure airways are clean and there are no obstructions at the exit from the wall.
Replacement Lamps
- Heat Lamps – Hard Glass, Infrared, R125, 240V, 275W
- Light Lamp – R63, 240V, 9W Max
Specifications
Model No | 20351/05 (2 Heat Lamps), 20352/05 (4 Heat Lamps) |
---|---|
Fascia colour | /05 – White |
Rating | 240V, 50Hz, 594W (20351/05), 1144W (20352/05) |
Heat Lamps | 240VAC, R125, E27, 275W |
LED Lamp | 9W, 860lm, Cool White, Non dimmable |
Airflow | 240m3/h (at exit point from the unit) |
Cut out hole size | 345mm x 185mm (20351/05), 295mm x 295mm (20352/05) |
Dimensions
| 20351/05 – 400mm L x 225mm W x (180mm H excluding grille) 20352/05 – 362mm
L x 362mm W x (175mm H excluding grille)
Noise| <45dB
IP rating| IPX2
Weight| 3.0kg (20351/05), 3.6kg (20352/05)
Warranty
Brilliant Lighting warrants this product against defects in manufacture and
workmanship for a period of 3 years from date of purchase.. This warranty is
only valid for products installed by a qualified electrical contractor and
operated within the guidelines specified by Brilliant Lighting, and within the
correct operating voltage ranges as stated on the product’s rating label.
Warranty does not include damage or loss arising from incorrect installation,
operation or maintenance of this product, damage caused through modification,
incorrect installation, service by unqualified or unauthorised personnel or
lack of regular maintenance and cleaning. Proof of installation by qualified
personnel may be required, e.g.. Electrical Safety Certificate. Proof of
purchase must be supplied with all warranty claims.
This warranty is provided in addition to any other rights and remedies of the
customer under any law. In applications not intended for household, personal
or domestic use, liability is limited to replacement or reimbursement of
product only.
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure
and compensation for any other reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced if goods fail to be of
acceptable quality and the failure does not amount to a major failure.
Any claim under this warranty must be made within the specified warranty
period from date of purchase of this product. To make a claim under the
warranty, take the product (with proof of purchase – receipt or similar) to
the store where you purchased the product or contact Brilliant Lighting at the
address below.
This warranty is given by:
Brilliant Lighting (Aust) Pty. Ltd.
ABN 37 006 203 694 956 Stud Road Rowville, VIC 3178
Phone: 03 9765 2555
Email: info@brilliantlighting.com.au
Made in China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>