Ptxson TX-H60 Oxy-Hydrogen Generator Instruction Manual

June 12, 2024
Ptxson

Oxy-Hydrogen Generator
Manual Book for Operation and Maintenance

TX-H60 Oxy-Hydrogen Generator

Models Available

TX-H60| TX-H100| TX-H150

ATTENTIONS

  • We are engaged in product improvement, Change may occur.

  • We are not responsible for occasional damage accidents under abnormal or specific working environment.

  • We are not responsible for damages or losts caused by misoperation.

  • No copy is allowed without permission.
    Danger : can cause human injury
    Warning   : can cause human injury
    Notice : may cause product damage or properly losses
    Note: means hint to operation and maintenance.

  • Any questions or any problems,please contact us or local distributors.

  • This manual book is part of machine,please take care to keep.

Goods Inspection after Arriving

  • Inpection whether there is any damage,such as shell damage or inside damage,lf so,please take a photo,and declare losses to the transportation company
  • Check product model,tech data(power supply,voltage,frequency) and accessories to judge whether the machine meets your requirements.

Please operate the machine according to this manual book.
Don’ t use the machine under abnormal working environment.
Any questions or any needs, please contact local distributors or us.
We are not responsible for the machine changed by others without our company’s paper approval.

Safety

**danger**

  • Water is forbidden into the inside of the machine because there are many electric parts.
  • Don’ t open shell before power off.
  • Don’ t open upper nut if therre is pressure inside machine

**warning**

  • The electrolytic sollution is highly corrosive.
  • Flame tempearture is 2800’C.Don’t misplace messily when burning.
  • Use plug with earth wire.
  • Ignition is forbidden when there is no pressure inside the machine.

notice

  • Clean electrolytic cells every two months.
  • Release the left gas after you shut down the machine

Warranty

4. 1 warranty
terms warrany period: We offer 12 months free maintenance from the purchasing day, and lifetime paid maintenace.
Following terms have no free maintenance:

  • Surpass warranty period-12months
  • Change warranty period without authorization
  • Operate or maintain the machine wrongly without manual book instruction.
  • Disassemble the machine or accessories privately

4. 2 war ranty range

accessories 12 months lifetime paid no warranty
cells
power supply
pressure switch
filter
manometer
fan
flame torch
T-junction
hose
power cord
funnel
powder
flashback arrestor

Note: warranty period of main set is 11 months

Equipment data

model TX-H60 TX-H100 TX-H150
max. gas prduct 75 L/H 95L/H 150L/H
voltage AC220V 1. 2A AC220V 1. 5A AC220V 2. 5A
AC110V 2. 5A AC110V 3.1A AC110V 5. 5A
water consumes 25 mL/H 30 mL/H 50 mL/H
max.water adding 1.0 L 1.0 L 4.2 L
solution density 15% 15% 15%
pressure range 0.13-0. 15Mpa 0.13-0. 15Mpa 0.13-0. 15Mpa
weight 7 Kg 8 Kg 14 Kg
size 450280360mm 480280360mm 520300540mm
flashback arresor
T —junction
cell QUA 1 1 2
flame torch 1 1 2
hose 1 1 4
powder 1 1 2

Note: “ ” has, ” ” has not

Graphic illustration

6.1 main setPtxson TX H60 Oxy Hydrogen Generator -
Grapice

  1. lifting
  2. trademark
  3. current
  4. fans
  5. on/off
  6. feeding inlet
  7. pressure valve pressure gauge
  8. gas output
  9. filter cup
  10. waterline
  11. power cord
  12. data sticker
  13. fans
    Note: TX-H60 has pressure releasing valve,and TX-H100 has pressure gauge.

Installation operation

7.1 make electrolytic solution

model TX-H60 TX-H100 TX-H150
ratio 1.0L 1.0L 4.2L

Add electrolytic powder(sodium hydroxide or NaOH) and water in a plastic basin or glass and ceramic basin, stir them, and then cool for 10 minutes. electrolytic solution ratio: 1590
**   Notice: metal basin is forbidden.
****
Warning :** Sodium hydroxide belongs to strong alkali,so its solution is very corrosive once the solution touches clothes or skin, please clean it using water repeatedly.

7.2 add electrolytic solutionPtxson TX H60 Oxy Hydrogen Generator -
Solution 1

  1. unscrew the inlet nut.
  2. put the funnel to avoid spattering.
  3. add electrolytic solution into the electrolytic cells.
  4. electrolytic solution must be lower than”normal waterline”, and must be higher than”feeding waterline”.
  5. tighen the inlet nut.

7.3 add filter solutionPtxson TX H60 Oxy Hydrogen Generator - Solution
2

  1. Disassemble the filter cup anticlockwisely.
  2. Add alcohol to the cup lower than 1/3 of the cup.
  3. Assemble the filter cup to the machine and tighten it. note: the filter solution is distilled water or alcohol which adjusts flame pureness and temperature.

7.4 power on testPtxson TX H60 Oxy Hydrogen Generator - Solution
3

  1. Check techdata label on the back of machine shell.We produce acrylic flame polisher with 110V and 220V power supply voltage.Power supply voltage and the voltage machine needs must be matchable to avoid damage to the machine.
  2. The plug must have the earth wire to avoid electric shock.
  3. The hose connects flame toch and gas output. Choose suitable copper nozzles according to your requirements.
  4. Power on, if both light and fan works, the machine is working well.

7.5 pressure testPtxson TX H60 Oxy Hydrogen Generator -
Operation
Close the flame torch, and gas pressure will become higher and higher.When it reaches its limit, current value will become zero,and machine will stop work. Then lift the pressure-releasing valve, there will be gas releasing.ln that case,the machine works well.
Working pressure range is from 0. 13Mpa to O. 15Mpa.lf pressure reaches to 0.15 Mpa, machine will stop working, while if pressure becomes 0.13 Mpa, machine will work again automatically.ln that case, machine works well.

7. 6 usage
Ignite in the copper nozzle, then let the flame burn the acrylic sheets or signs equably in suitable distance, not too near and not too far.Only burn one time equably.
note: For fist-time use or exchange electrolytic solution, when the machine produces gases, open the flame torch to release the left gas inside the machine, and then ignite the flame.( It needs only 20 seconds)

Equipment maintenance

  1. Add water timely: if waterline reaches the feeding waterline, add water into the machine to make waterline back to the normal waterline.( no need of electrolytic solution)
  2. Exchange electroytic solution each month or when the solution becomes dark and dirty, or useless because mixed with alcohol. Clean the electrolytic cell before adding new electrolytic solution.
  3. When add water, exchange solution or add alcohol, your must shut down the machine and turn off flame torch. If all is done, release the left gases before igniting the flame torch.

Simple breakdowns and solutions

breakdowns reasons solutions
red or yellow flame new machine let machine works for a while
add more filter so I ut ion pour out add itiona I filter soIution
dirty  copper nozzles clean  copper nozzles
less pressure I ow cur rent value exchange electrolytic solution
gas leakage turn off flame torch and power on the machine, using soap water

to find the leakage place  and mend it.
flameback| gas leakage| check leakage place
anti—flameback device damage| exchange flameback  arrestor device
no pressure| gas leakage| check leakage place
pressure gauge damage| exchange pressure gauge
no cur rent| power supply, current gauge, pressure device damage| exchange damaged parts
output of power supply is DC24V and DC10A pressure range is from O. 13Mpa to0. 15Mpa
electricity wire damage| check electricity wire breakdowns.