Ptxson TX-H60 Oxy-Hydrogen Generator Instruction Manual
- June 12, 2024
- Ptxson
Table of Contents
Oxy-Hydrogen Generator
Manual Book for Operation and Maintenance
TX-H60 Oxy-Hydrogen Generator
Models Available
TX-H60| TX-H100| TX-H150
ATTENTIONS
-
We are engaged in product improvement, Change may occur.
-
We are not responsible for occasional damage accidents under abnormal or specific working environment.
-
We are not responsible for damages or losts caused by misoperation.
-
No copy is allowed without permission.
Danger : can cause human injury
Warning : can cause human injury
Notice : may cause product damage or properly losses
Note: means hint to operation and maintenance. -
Any questions or any problems,please contact us or local distributors.
-
This manual book is part of machine,please take care to keep.
Goods Inspection after Arriving
- Inpection whether there is any damage,such as shell damage or inside damage,lf so,please take a photo,and declare losses to the transportation company
- Check product model,tech data(power supply,voltage,frequency) and accessories to judge whether the machine meets your requirements.
Please operate the machine according to this manual book.
Don’ t use the machine under abnormal working environment.
Any questions or any needs, please contact local distributors or us.
We are not responsible for the machine changed by others without our company’s
paper approval.
Safety
**danger**
- Water is forbidden into the inside of the machine because there are many electric parts.
- Don’ t open shell before power off.
- Don’ t open upper nut if therre is pressure inside machine
**warning**
- The electrolytic sollution is highly corrosive.
- Flame tempearture is 2800’C.Don’t misplace messily when burning.
- Use plug with earth wire.
- Ignition is forbidden when there is no pressure inside the machine.
notice
- Clean electrolytic cells every two months.
- Release the left gas after you shut down the machine
Warranty
4. 1 warranty
terms warrany period: We offer 12 months free maintenance from the purchasing
day, and lifetime paid maintenace.
Following terms have no free maintenance:
- Surpass warranty period-12months
- Change warranty period without authorization
- Operate or maintain the machine wrongly without manual book instruction.
- Disassemble the machine or accessories privately
4. 2 war ranty range
accessories | 12 months | lifetime paid | no warranty |
---|---|---|---|
cells | |||
power supply | |||
pressure switch | |||
filter | |||
manometer | |||
fan | |||
flame torch | |||
T-junction | |||
hose | |||
power cord | |||
funnel | |||
powder | |||
flashback arrestor |
Note: warranty period of main set is 11 months
Equipment data
model | TX-H60 | TX-H100 | TX-H150 |
---|---|---|---|
max. gas prduct | 75 L/H | 95L/H | 150L/H |
voltage | AC220V 1. 2A | AC220V 1. 5A | AC220V 2. 5A |
AC110V 2. 5A | AC110V 3.1A | AC110V 5. 5A | |
water consumes | 25 mL/H | 30 mL/H | 50 mL/H |
max.water adding | 1.0 L | 1.0 L | 4.2 L |
solution density | 15% | 15% | 15% |
pressure range | 0.13-0. 15Mpa | 0.13-0. 15Mpa | 0.13-0. 15Mpa |
weight | 7 Kg | 8 Kg | 14 Kg |
size | 450280360mm | 480280360mm | 520300540mm |
flashback arresor | |||
T —junction | |||
cell QUA | 1 | 1 | 2 |
flame torch | 1 | 1 | 2 |
hose | 1 | 1 | 4 |
powder | 1 | 1 | 2 |
Note: “ ” has, ” ” has not
Graphic illustration
6.1 main set
- lifting
- trademark
- current
- fans
- on/off
- feeding inlet
- pressure valve pressure gauge
- gas output
- filter cup
- waterline
- power cord
- data sticker
- fans
Note: TX-H60 has pressure releasing valve,and TX-H100 has pressure gauge.
Installation operation
7.1 make electrolytic solution
model | TX-H60 | TX-H100 | TX-H150 |
---|---|---|---|
ratio | 1.0L | 1.0L | 4.2L |
Add electrolytic powder(sodium hydroxide or NaOH) and water in a plastic basin
or glass and ceramic basin, stir them, and then cool for 10 minutes.
electrolytic solution ratio: 1590
** Notice: metal basin is forbidden.
****Warning :** Sodium hydroxide belongs to strong alkali,so its solution
is very corrosive once the solution touches clothes or skin, please clean it
using water repeatedly.
7.2 add electrolytic solution
- unscrew the inlet nut.
- put the funnel to avoid spattering.
- add electrolytic solution into the electrolytic cells.
- electrolytic solution must be lower than”normal waterline”, and must be higher than”feeding waterline”.
- tighen the inlet nut.
7.3 add filter solution
- Disassemble the filter cup anticlockwisely.
- Add alcohol to the cup lower than 1/3 of the cup.
- Assemble the filter cup to the machine and tighten it. note: the filter solution is distilled water or alcohol which adjusts flame pureness and temperature.
7.4 power on test
- Check techdata label on the back of machine shell.We produce acrylic flame polisher with 110V and 220V power supply voltage.Power supply voltage and the voltage machine needs must be matchable to avoid damage to the machine.
- The plug must have the earth wire to avoid electric shock.
- The hose connects flame toch and gas output. Choose suitable copper nozzles according to your requirements.
- Power on, if both light and fan works, the machine is working well.
7.5 pressure test
Close the flame torch, and gas pressure will become higher and higher.When it
reaches its limit, current value will become zero,and machine will stop work.
Then lift the pressure-releasing valve, there will be gas releasing.ln that
case,the machine works well.
Working pressure range is from 0. 13Mpa to O. 15Mpa.lf pressure reaches to
0.15 Mpa, machine will stop working, while if pressure becomes 0.13 Mpa,
machine will work again automatically.ln that case, machine works well.
7. 6 usage
Ignite in the copper nozzle, then let the flame burn the acrylic sheets or
signs equably in suitable distance, not too near and not too far.Only burn one
time equably.
note: For fist-time use or exchange electrolytic solution, when the
machine produces gases, open the flame torch to release the left gas inside
the machine, and then ignite the flame.( It needs only 20 seconds)
Equipment maintenance
- Add water timely: if waterline reaches the feeding waterline, add water into the machine to make waterline back to the normal waterline.( no need of electrolytic solution)
- Exchange electroytic solution each month or when the solution becomes dark and dirty, or useless because mixed with alcohol. Clean the electrolytic cell before adding new electrolytic solution.
- When add water, exchange solution or add alcohol, your must shut down the machine and turn off flame torch. If all is done, release the left gases before igniting the flame torch.
Simple breakdowns and solutions
breakdowns | reasons | solutions |
---|---|---|
red or yellow flame | new machine | let machine works for a while |
add more filter so I ut ion | pour out add itiona I filter soIution | |
dirty copper nozzles | clean copper nozzles | |
less pressure | I ow cur rent value | exchange electrolytic solution |
gas leakage | turn off flame torch and power on the machine, using soap water |
to find the leakage place and mend it.
flameback| gas leakage| check leakage place
anti—flameback device damage| exchange flameback arrestor device
no pressure| gas leakage| check leakage place
pressure gauge damage| exchange pressure gauge
no cur rent| power supply, current gauge, pressure device damage| exchange
damaged parts
output of power supply is DC24V and DC10A pressure range is from O. 13Mpa to0.
15Mpa
electricity wire damage| check electricity wire breakdowns.