Product Information
The EUV POD Barcode Reader GD-BAR01 is a tool that performs the following functions automatically or manually: 1. RFID Reading. 2. Pellicle Detect 3. Mask ID Read 4. EIP ID Read. It is important to note that the maintenance of this equipment must be carried out by trained and qualified personnel.
Home Page
The Home page is the main page of the EUV POD Barcode Reader GD-BAR01. It contains the following functions:
- System ON: Push Button of executing auto run.
- System OFF: Push Button of Stopping the process.(Press more than 3 secs)
- SECS Connection: Communication status of SECS
- Status: Status of this tool.(Initialization Idle RFID Reading POD ID Reading MASK ID Reading Completed END)
- Ready to Unload/Ready to load: Ready to Load or Ready to Unload Status.
- Alarm Reset: Push button of Alarm resetting.
- POD ID: POD ID data.
- MASK ID: Mask ID data.
- RFID LEFT: RFID reading data (left).
- RFID RIGHT: RFID reading data (right).
The Home page also contains a Menu button with the following options:
- Login: User Login.
- Manual: Switch to manual mode.
- E84: Switch to E84 setting page.
- IO: Switch to I/O monitor page.
- Log: History log and SECS Log.
- On Line: SECS On-line.
- Off Line: SECS Off-Line.
- Exit: Exit Gudengview.
- ALARM: Alarm List.
- RFID Write: RFID Writing manual page.
- CCD: Pellicle camera screen.
- Minimized: Minimize the Gudengview window to reveal the desktop.
EB NO. Writing
In the automatic starting, the EBNO input blank will appear only when the comparison process fails, and the EBNO can be written. (MASK ID is different from the content of RFID).
Outline and safety
This operation manual is aimed at explaining how to use the Barcode reader(GD-
BAR01). Before operating this tool, please be sure to read this book
carefully, and understand the contents recorded in this book in order to be
able to use this tool flexibly. Also, please take care of this book so that it
can be taken for reference immediately when necessary.
< Who should read this book>
The purpose of this book is written on the premise of enabling users to have a
deeper understanding of the tool.
Notation of this book
- 【 】button: The button displayed on the operation panel and touch screen.
- 「 」Equipment status: Indicates the current status of the tool
- 『 』Indicator: The indicator lamps displayed on the operation panel and touch screen.
Danger
With wrong operation, it may cause serious injury to the user and other
imminent danger.
Warnig
With wrong operation, it may cause trouble to the user. or may cause damage to
items.
Notice This Transmitter must not be co-located or operating in
conjunction with any other antenna or transmitter.
Warning: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user authority to operate
the equipment.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Please read this operation manual carefully and operate correctly under the condition of safety first.
Warning Labeling Location
Operational Description
This tool performs the following functions automatically or manually:
- RFID Reading.
- Pellicle Detect
- Mask ID Read
- EIP ID Read
Operation
The maintenance of this equipment must be carried out by trained and qualified personnel. It is strictly forbidden for ordinary operators to operate or disassemble the equipment arbitrarily to avoid dangerous incidents.
(一) Home page
Function description of Home page:
- System ON: Push Button of executing auto run.
- System OFF: Push Button of Stopping the process. (Press more than 3 secs).
- SECS Connection: Communication status of SECS.
- Status: Status of this tool.(Initialization、Idle、RFID Reading、POD ID Reading、MASK ID Reading、Completed、END)
- Ready to Unload/Ready to load: Ready to Load or Ready to Unload Status.
- Alarm Reset: Push button of Alarm resetting.
- POD ID: POD ID data.
- MASK ID: Mask ID data.
- RFID LEFT: RFID reading data (left).
- RFID RIGHT: RFID reading data (right).
Menu button:
- Login: User Login.
- Manual: Switch to manual mode.
- E84: Switch to E84 setting page.
- I/O: Switch to I/O monitor page.
- Log: History log and SECS Log.
- On-Line: SECS On-line.
- Off-Line: SECS Off-Line.
- Exit: Exit Gudengview.
- ALARM: Alarm List.
- RFID Write: RFID Writing manual page.
- CCD: Pellicle camera screen.
- Minimized: Minimize the Gudengview window to reveal the desktop.
EB NO. Writing
In the automatic starting, the EBNO input blank will appear only when the
comparison process fails, and the EBNO can be written. (MASK ID is different
from the content of RFID).
(二)Manual Operation:
Press[Manual] button, the screen will switch to the manual operation page.
Composition of manual operation page:
To operate the tool manually,users have to perform stop function on Home Page
first. Then the status field will display “stop”. Next, please press the
【Manual】 button to switch to the manual operation page.
- Green: Indicates moving.
- Gray: Indicates not moving.
- Ori Initial: Press this PB to return to the original point of QR-code CCD Axis.
- LEFT JOG+: Jog forward (left side from operator).
- RIGHT JOG-: Jog backward (right side from operator).
- Move to MASK ID: Move to the setting position of MASK ID reading.
- Move to EIP ID: Move to the setting position of EIP ID reading.
- QR-Photograph: Trigger the QR-code read at MASK ID reading or EIP ID reading position.
- :Display the data read from the CCD.
- POD ID: Display the POD ID of the product.
- MASK ID: Display the MASK ID of the produc.
- RFID LEFT: Display the data read from the left RFID.
- RFID RIGHT: Display the data read from the right RFID.
- Move speed: Set the moving speed of QR-code CCD axis.
- Inching speed: Set the jog speed of QR-code CCD axis.
- Left Position: Set the position of mask ID reading.
- Right Position: Set the position of EIP ID reading.
- Position: Display the current position of the QR-code CCD axis.
- Buzzer On/Off: Mute or turn on the buzzer.
CCD adjustment:
Enter the CCD setting page, users can watch the CCD screen and adjust the
position of CCD axis at the same time. CCD adjustment must be operated by
Gudeng engineers or trained personnel.
(三)I/O List:
I/O is Input and Output. X represents input contacts, Y represents output
contacts.
(四)System On operation screen
- Step 1: Preparation
- Press the 【SystemOn】 button to start automatic operation, and the status display will change to a green background display.
- To cancel the automatic operation, press 【SystemOFF】 button for 3 seconds, and the automatic operation will stop.
- Step 2: The action of autorun
- Initialization => Idle(Ready to Load) => RFIDRead => Pellicle detect => Move to EIP ID reading position => Move to Mask ID reading position => Completed(Ready toUnload) => END.
- To cancel the automatic operation, press 【SystemOFF】 button for 3 seconds, and the automatic operation will stop.
(五)User Log in
When you click 【Login】on the Home Page, the following screen will pop up
.
- Choose the user name.
- Key in the password, then press 【Login】.
- When the system is turned on, it will automatically log in to the OP operator.
- The operator cannot operate the following buttons “Manual, OnLine, OffLine, Exit, Minimized”, and other personnel need to log in to enter the screen.
- The default password of Manager is 1234.
(六)E84 Communication status and alarm display:
- Auto: The system will automatically switch the E84 mode to auto.
- Manual: The system will automatically switch the E84 mode to manual.
(七)SECS Control State:
When the system is turned on, the default mode is Online-Remote, wait for
the Host to connect, and the general state is Online-Remote after connection;
- OFF-LINE: switch to OFFLINE.
- ON-LINE: Switch to online mode when Host is connected.
- Local: Switch the mode to Online-Local.
- Remote: Switch the mode to Online-Remote.
(八)Log:
- Event Log: Display the event history
- SECS Log: Display the SECS Log
(九)RFID Write(Manual Mode):
- Enter the string that will be written into the MASK ID of RFID, press the 【RFID write】on the right to execute the write function, and feedback the result of this RFID writing OK or NG.
- Press “RFID Read” on the right to read the current RFID content, and feedback the RFID reading result OK or NG.
(十)CCD:
- On this screen, you can see the latest picture of scanned Pellicle and the test result.