1 IP66-1P65
2 IP66-1P65-1P44
3 1P66-1P65-1P44-1P43-1P21

| 3945 CORVUS Ceiling and Wall Lamps - 3
---|---

A cracked safety glass lampshade must be replaced. Beschädigtes Glas ersetzen.

CONNECTION TO THE NETWORK

Protection class Schutzklasse

N| blue (neutral wire)| L| brown/black (phase)| ****| yellow/green
---|---|---|---|---|---

SUBJECTION TO THE WALL

3945 CORVUS Ceiling and Wall Lamps - 5

Technical data: see fixture label
Inglés: This product contains a light source of the energy efficiency class F.

SAFETY INSTRUCTIONS

  1. Electrical appliances must only be connected by qualified persons.
  2. Important! Before starting installation work disconnect the main cable from the power supply – remove the fuse or turn the switch to «OFF». The power supply connection must be done with a suitable connecting box, as seen in the illustrations.
  3. The lamps with an index of protection 20 (IP20) cannot be used outdoors.
  4. Lamps marked with the symbol may not be installed on easily flammable surfaces such as wood, or carpet.
  5. Do not attach lamps on surfaces that are damp, freshly painted, or otherwise e electrically conductive.
  6. Connect the wires of the lamp with the same color as the wires of the wall or the cell. PE or = green/yellow = ground wire. N =blue=neutral wire. L=brown (black) = phase.
  7. Use the fixation system according to the weight of the lamp.
  8. Keep away the wires and connections from heat sources.
  9. Make sure that the wiring is not damaged during de drilling /fixing procedure.
  10. Be sure to always use the correct type of bulb (see information on the label!).
  11. Keep these instructions in a safe place.
  12. Use the sleeves to cover the main supply wiring to the fitting.
  13. Cleaning is limited to the outer surfaces, shades or protective glass, reflectors, and covers. It is important to ensure that no moisture enters the terminal compartment or reaches any live parts! Gold and brass finishing lamps can be cleaned only with a soft cloth (do not use cleaning agents of any kind).
  14. Use low-pressure halogen lamps with low ultraviolet radiation (UV-STOP). 15. Suitable only for indoor use, at 25ºC.

EXPLANATION OF PROTECTION CLASSES:
** Protection class I: This lamp has an earth terminal. The earth wire (yellow and green) must be connected to the terminal indicated by the symbol.
velleman DCM268 AC &amp DC CLAMP METER - FIG 7** Protection class II: This lamp is double insulated and must not be connected to an earth wire.
All the technological LED lamps are constructed with
Led systems cannot be replaced.

STAMP OF THE COMPANY

The manufacturer guarantees the proper functioning of this equipment, repairs, or spare parts of the model owing to faulty manufacture 3 years after the surrender date. Responsibility will not be accepted, however, for damages or injury caused through misuse, For any claims the sale ticket must be presented. The company agrees to repair any defect or malfunction found in the item and any damages said defect or malfunction might directly provoque. If the repair should fail to satisfy the customer and/or the object fail to present the optimum condition for the use to which it is destined the guarantee holder will have the right to the substitution of the acquired item for another of identical characteristics or a complete refund of the purchase price.

PRODUCTO FABRICADO EN ESPAÑA
C.I.F B-96498233
Camino Valencia, 104. 46190 RIBA-ROJA DEL TÚRIA (Valencia – España)

Documents / Resources

| CORVUS 3945 CORVUS Ceiling and Wall Lamps [pdf] Instructions
3945, CORVUS Ceiling and Wall Lamps, 3945 CORVUS, Ceiling and Wall Lamps, 3945 CORVUS Ceiling and Wall Lamps, Wall Lamps, Lamps
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals