Puretec SOL-E3 Series Volumetric Water Softening Appliance
Product Information
Puretec SOL-E3 Volumetric Water Softening Appliance
- Manufacturer: Pro-Switch Pty Ltd
- Model Number: ATS5200.103
- Licence No.: WM 74593
- Designed for metropolitan supply water, but can be used in other situations with appropriate consultation with a local Puretec dealer.
- Flush system for 5 minutes or more after any period of non-use more than 2 weeks.
- Water softener salt is not supplied.
- Chlorine tolerance is 1ppm – high chlorine levels permanently damage the softening resin and are not covered under warranty. If chlorine exceeds this limit, a carbon pre-filter such as the WH2 or CFS Series is recommended to prolong the resin life.
- Installation should be completed by qualified tradespeople. Faulty operation due to unqualified persons will result in voided warranty coverage.
Product Usage Instructions
- Keep batteries out of reach of children as they can cause severe or fatal injuries if swallowed.
- If you suspect that your child has swallowed or inserted a button battery, immediately call the 24-hour Poisons Information Centre 13 11 26 (in Australia).
- For correct operation and installation, observe the instructions provided in the user guide.
- Ensure that the information and illustration provided in the user guide is applicable to your particular unit.
- Do not use with water that is microbiologically unsafe or without adequate disinfection before or after the system.
- Flush the system for 5 minutes or more after any period of non-use that exceeds 2 weeks.
- Water softener salt is not supplied.
- Chlorine tolerance is 1ppm – high chlorine levels permanently damage the softening resin and are not covered under warranty. If chlorine exceeds this limit, a carbon pre-filter such as the WH2 or CFS Series is recommended to prolong the resin life.
- Installation should be completed by qualified tradespeople. Faulty operation due to unqualified persons will result in voided warranty coverage.
Note: The installation record provided in the user guide can be filled for future reference. Make sure to get your water thoroughly tested and select the location of your water softener carefully.
Warning: THIS PRODUCT CONTAINS A BUTTON BATTERY
- If swallowed, a lithium button bettery can cause severe or fatal injuries within 2 hours.
- Keep batteries out of reach of children.
- If you suspect your child has swallowed or inserted a button battery, immediately call the 24-hour Poisons Information Centre 13 11 26 (in Australia).
Caution
- DO NOT OVERTIGHTEN.
- DO NOT USE LIQUID SEALANTS.
Puretec Customer Service
Thank you for purchasing a Puretec Softrol Volumetric Water Softening System. Your system is a proven performer manufactured from only quality materials and components. It will give years of reliability and trouble free operation if maintained properly. This user guide is designed for Puretec SOL-E3 Water Treatment Systems. Be careful to ensure the information and illustration is applicable to your particular unit.
Caution: Do not use with water that is microbiologically unsafe or without adequate disinfection before or after the system.
The systems are designed for metropolitan supply water but can be used in other situations. For other types of water supply, please contact your local Puretec dealer. Puretec Water Softeners are designed to run economically for many years, dependent on the initial installation and periodic maintenance. Flush system for 5 minutes or more, after any period of non-use, more than 2 weeks.
Note: Water softener salt not supplied.
Installation Note
A water filter system/tap, like any product, has a limited lifespan and if not replaced, will eventually fail. Failure can happen early due to unforeseen circumstances. To avoid possible property damage, this product should be regularly examined for leakage and/or deterioration and replaced when necessary. We strongly recommend that a drain pan, plumbed to an appropriate drain or outfitted with a leak detector, be used in those applications where any leakage could cause property damage. We also strongly recommend that the water supply be turned off, upstream to the water filter system/tap, if no one is home for an extended period of time.
INSTALLATION SHOULD BE COMPLETED BY QUALIFIED TRADESPEOPLE. FAULTY OPERATION DUE TO UNQUALIFIED PERSONS WILL RESULT IN VOIDED WARRANTY COVERAGE.
Warning: Chlorine (free chlorine) tolerance is 1ppm – high chlorine levels permanently damage the softening resin & is not covered under warranty. If chlorine exceeds this limit, we recommend a carbon pre-filter such as the WH2 or CFS Series. Please refer to Puretec for a specific recommendation. In any case, a carbon pre-filter is recommended to protect against chlorine spikes & prolong the resin life.
Installation Record
For future reference, fill in the following data
Product Information
Model Number:|
Serial / Batch Number:|
Purchased from:|
Date of Installation:|
Installer / Plumber Details:|
Water Analysis Information
Hardness:| ppm / mg/L
Iron:| ppm / mg/L
Manganese:| ppm / mg/L
pH:|
TDS (Total Dissolved Salts):| ppm / mg/L
Conductivity:| EC / uS/cm
Chloride:| ppm / mg/L
Sodium:| __ ppm / mg/L
Before Installation
Professional Installation Required
- Installation requires shutting water off to home, cutting home water supply pipe and using a welding torch to add piping and fittings. Specialized tools and skills are required, this must be completed by a qualified tradesperson.
Make Sure Your Water Has Been Thoroughly Tested
- An analysis of your water should be made prior to the selection of your water conditioning equipment. Your dealer will generally perform this service for you, and may send a sample to the factory for analysis and recommendations. Enter your analysis information on page 4 for your permanent record.
- Softeners are designed to reduce hardness but can handle reasonable amounts of soluble iron if consideration is given to content when selecting model and regeneration settings. For best results contact Puretec to discuss.
Install Water Conditioning Equipment Correctly
Select the location of your water softener with care. Various conditions which contribute to proper location are as follows:
- Install as close as possible to a drain.
- Install in correct relationship to other water treatment equipment. Contact Puretec for assistance.
- Install the softener in the supply line BEFORE the water heater. Temperatures above 43.3°C (110°F) will damage the softener and void the warranty.
- DO NOT install the softener in a location where freezing temperatures occur. Freezing may cause permanent damage and will also void the warranty.
- DO NOT install where water hammer conditions may occur without installing an arrestor.
- Allow sufficient space around the installation for easy servicing. Provide a nonswitched 240V power source for the control valve.
- Protect from pressure vacuum with a suitable vacuum breaker.
- Where line pressure exceeds 500 kPa, an approved pressure limiting device must be installed to comply with Australian & New Zealand Plumbing Standards. (Ref. AS/NZS 3500.1:2021, Clause 3.3.4).
- For point of entry installations an approved backflow prevention device must be installed.
Things to Remember While Planning Your Installation
- All installation procedures MUST conform to local plumbing codes.
- If lawn sprinklers, a swimming pool, or geothermal heating/cooling or water for other devices/activities are to be treated by the water softener, a larger model MUST be selected to accommodate the higher flow rate plus the backwashing requirements of the water softener. Contact Puretec for assistance.
WARNING: THESE STEPS ARE CRITICAL FOR THE CORRECT INSTALLATION OF YOUR WATER TREATMENT SYSTEM.
- The control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignment but are not designed to support the weight of a system or the plumbing.
- The unit must be installed on a surface that is firm, level, horizontal in both directions and fully supports the entire base of the softener. The softener can weigh a considerable amount when full and the base must be suitable to support this weight.
- Do not use petroleum jelly, oils, other hydrocarbon lubricants or spray silicone anywhere. A silicon lubricant may be used on the black o-rings but it is not necessary.
- Do not use pipe dope or other sealants on threads. Thread seal tape is the preferred sealant but is not necessary on the nut connection or caps because of o-ring seals.
- All plumbing should be done in accordance with local plumbing codes. The pipe size for the drain line should be a minimum of ⅝”.
- Avoid getting primer and solvent cement on filter system.
- Install grounding strap on metal pipes if required.
- Ensure the system is protected against high pressure and extreme temperatures.
- Chlorine (free chlorine) tolerance is 1ppm – high chlorine levels permanently damage the softening resin & is not covered under warranty. If chlorine exceeds this limit, we recommend a carbon pre-filter such as the WH2 or CFS Series. Please refer to Puretec for a specific recommendation. In any case, a carbon pre-filter is recommended to protect against chlorine spikes & prolong the resin life.
- If pressure exceeds 500 kPa an approved pressure limiting device needs to be fitted.
Specifications
Operating Pressure Min/Max: | 138 – 862* kPa |
---|---|
Operating Temperature Min/Max: | 0 – 48 °C (protect from |
freezing)
Electrical Connection:| 240V / 50 Hz
Inlet/Outlet Connection:| 25 mm
Drain Connection:| ⅝”
Overflow Connection:| ⅝”
Width (mm) (W):| 350
Height (mm) (H):| 1125
Depth (mm) (D):| 490
Dry Weight (kg):| SOL30-EExploded Diagram3 – 29 kg.
SOL40-E3 – 37 kg.
Maximum salt storage capacity:| 50 kg
- Where line pressure exceeds 500 kPa, an approved pressure limiting device must be installed to comply with Australian & New Zealand Plumbing Standards. (Ref. AS/NZS 3500.1:2021, Clause 3.3.4).
Exploded Diagram
Parts Identification
Item| Part no| Description| | Item| Part no| Description|
---|---|---|---|---|---|---|---
1| WTD2030| Riser Pipe| 11| WTD1010| Top Screen|
2| –| Pressure Tank| 12| WTV4200| Volumetric Valve|
3| WTB1035| Cabinet Domestic Softener| 13| WTV5135| Transformer Suits Auto
Valves|
4| –| Brine Well| 14| –| Drain Tube Assembly|
5| | Brine Pick-Up Assembly| 15| WTB2100| Softener Cover|
6| WTB1035| 2pc Overflow Kit| 16| WTV5060| Plastic Fitting Kit|
7| –| Brine Tank Lid| 17| WTV5000| Bypass Assembly (purchased
separately)
|
8| –| Brine Well Blank|
18| KTU6BK| Tubing High Pressure 3/8″ Black|
9| –| Brine Well Lid|
|
10| WTV3030| Pressure Tank Collar UV Shield|
Diagram Identification
Installation Procedure
Unpack the Equipment
Ensure all parts are present and have not been damaged in transport. You should have:
Extra Items Required
- Bag of Salt (refer for the type of salt to be used).
- ⅝” Tubing high pressure for drain and overflow.
Ensure Water Has Been Tested
- Input values into Table on and the analysis has been inspected by Puretec.
- Position the Softener on a level surface. The unit must be installed on a surface or pad that is stable, level and able to support the entire base and wet weight of the unit.
Environmental conditions
- Operating temperature: 0 – 48°C
Water conditions
- Temperature: 0 – 50°C
- Pressure: 138 – 862* kPa
Where line pressure exceeds 500 kPa, an approved pressure limiting device must be installed to comply with Australian & New Zealand Plumbing Standards. (Ref. AS/NZS 3500.1:2021, Clause 3.3.4).
Installing the Bypass (optional – purchased separately)
- Uninstall the plastic fittings by turning the knob counter clockwise.
- Connect the bypass assembly followed by the plastic fittings. Hand tighten the knobs, do not overtighten.
Connecting the Softener
Connect the softener to main plumbing. Do not solder brass adapters while they are inserted in the control module. Pipework must be aligned correctly with the inlet and outlet ports. Failure to do so may cause the misalignment of the cabinet components.
Connecting the Drain Line
Connect extra tube (tubing not supplied) onto the 5/8” drain line (pre installed on the valve) from the valve to the drain. Ensure the drain line is not kinked. The line must not travel more than 2.4 m and no more than 6 m long from the valve, otherwise increase the diameter of the drain line. Connect drain and overflow to sewer or other approved salty water disposal point as approved by your local authority. Ensure drain line has an adequate air gap of 2 times the pipe diameter or 25 mm, whichever is larger.
Connecting the Overflow
Programming
- Plug into an uninterrupted electrical outlet.
- Note: the system transformers are not weather resistant and should be adequately protected. All electrical connections must be connected accordingly to local codes.
- Proceed to ‘Programming’ section.
Programming – E3
GENERAL OPERATION
When the system is operating one of two displays will be shown. Pressing NEXT will alternate between the displays. One of the displays is always the current time of day. The second display is one of the following: days remaining or gallons remaining. Days remaining is the number of days left before the system goes through a regeneration cycle. Capacity remaining is the number of gallons that will be treated before the system goes through a regeneration cycle. The user can scroll between the displays as desired.
If the system has called for a regeneration that will occur at the present time of regeneration, the words REGEN TODAY will appear on the display. When water is being treated (i.e. water is flowing through the system) the word ‘Softening’ or ‘Filtering’ flashed on the display if a water meter is installed.
SET TIME OF DAY
The user can also set the time of day. Time of day should only need to be set after expended power outages or when daylight savings begins or ends. If an extended power outage occurs, the time of day will flash on and off which indicates the time of day should be reset.
- Step 1: Press SET CLOCK
- Step 2: Current Time (hour): Set the hour of the day using or buttons.
- Press NEXT to go to step 3.
- Step 3: Current Time (minutes) : Set the minutes of the day using or buttons. Press NEXT to exit Set Clock.
- Press REGEN to return to the previous step.
OTHER SETTINGS
- Step 1: Press NEXT and simultaneously for 5 seconds.
- Step 2: Hardness : Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons. The default is 13 with value ranges from 1 to 150 in 1 grain increments. The conversion factor to mg/l or ppm is 17 (divide mg/l or ppm by 17 = grains/gallon).
- Step 3: Day Override: When gallon capacity is set to off, sets the number of days between regeneration. The default is set to 28 days. When gallon capacity is set to AUTO or to a number, sets the maximum number of days between regeneration. If value set to ‘OFF’ regeneration initiation is based solely on gallons used. If value is set as a number (allowable range from 1 to 28) a regeneration initiation will be called for on that day even if sufficient number of gallons were not used to call for a regeneration. Set Day Override using or buttons:
- Number of days between regeneration (1 to 28); or
- ‘OFF’
- Press NEXT to go to step 4. Press REGEN to return to previous step.
- Step 4: Next Regeneration Time (hour): Set the hour of the day for regeneration using or buttons. AM/PM toggles after 12. The default time is 2:00 am. Press NEXT to go to step 5. Press Regen to return to previous step.
- Step 5: Next Regeneration Time (minutes): Set the minutes of day for regeneration using or buttons. The default setting is ‘00’
- Press NEXT to exit Installer Displays/Settings.
- Press REGEN to return to previous step.
REGENERATION MODE
- Typically a system is set to regenerate at a time of low water usage. An example of a time with low water usage is when a household is asleep. If there is a demand for water when the system is regenerating, untreated water will be used.
- When the system begins to Regenerate, the display will change to include information about the step of the regeneration process and the time remaining for that step to be completed.
- The system runs through the steps automatically and will reset itself to provide treated water when the regeneration has been completed.
MANUAL REGENERATION
- Sometimes there is a need to regenerate the system sooner than when the system calls for it, usually referred to as a manual regeneration. Theremay be a period of heavy water usage because of guests or a heavy laundry day.
- To initiate a manual regeneration at the preset delayed regeneration time, when the regeneration time option is set to ‘NORMAL’ or ‘NORMAL + on0’, press and release ‘REGEN’. The words ‘REGEN TODAY’ will flash on the display to indicate that the system will regenerate at the present delayed regeneration time. If you pressed the ‘REGEN’ button in error, pressing the button again will cancel the request.
- Note: If the regeneration time option is set to ‘on 0’ there is no set delayed regeneration time so ‘REGEN TODAY’ will not activate if ‘REGEN’ button is pressed.
- To initiate a manual regeneration immediately, press and hold the ‘REGEN’ button for three seconds. The system will begin to regenerate immediately. The request cannot be cancelled.
Note: For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating.
POWER LOSS
Your Puretec electronic control valve maintains the time for up to 8 hours using the internal PCB battery if power is interrupted. Nonvolatile memory stores the stats & programming & are not affected by power outages. After 8 hours of backup use, replace the battery with a type 2032, 3-volt lithium coin cell battery. If the time flashes on & off after a power loss the time of day should be reset & the flat battery replaced. In the unlikely event of a power loss during backwash, when power is restored, a dry-reset should be performed (refer to page 19 ), followed by a manual backwash/regeneration (refer to above) if convenient.
Start-up
Now programming is completed you are ready to start the system.
- Fill the brine tank with ‘water softener’ salt to approximately half full (salt not included). This will require approximately 50 kg (this is only required initially).
- Add approximately 15 litres of water to the salt in the brine tank. This is only required for the initial setup.
- Note: The water level will drop significantly after the first backwash, and may disapppear below the salt line. This is normal and no extra water will be required.
- Open the nearest tap downstream of the filter system (after the filter system).
- Allow water to flow through the system slowly, and allow all air to escape out of the closest tap. Wait until the water is flowing out of the tap and then increase the flow slowly up to full flow. Allow to run for 5 – 10 minutes.
- Close the opened tap and check for leaks.
- Conduct a full manual regeneration.
- Your system is ready for use.
Regeneration
MODEL | CAPACITY OF SYSTEM (L) WITH DIFFERENT HARDNESS LEVELS |
---|---|
100 mg/L | |
SOL30-E3 | 10150 |
SOL40-E3 | 15400 |
E3 Valve: (Regeneration Time: 90 mins)
This will adjust regeneration automatically once you have entered the correct hardness level in the programming section.
Replenishment of Salt Supply
The salt storage capacity of the brine tank is approximately 50 kg. During each regeneration a small amount of salt is consumed, thus requiring periodic replenishment for a continuous supply of softened water (the frequency and salt dosage level is dependent on the regeneration schedule). We recommend to maintain the salt level in the brine tank to 1/2 to 2/3 full. The water level in the brine tank is maintained automatically and does not require manual intervention.
NOTE
- The water level is usually below the salt level & therefore cannot be seen (this is not a problem). Always replenish salt before the supply is exhausted.
- No extra water is required when topping up the salt level.
Type of Salt to Use
- Any type of water softener salt may be used, but for best results, we recommend using coarse solar salt called “water softener salt” or alternatively “pool salt”.
Media Replacement
Resin ordering code: RMK-SOL30 for SOL30-E3 and RMK-SOL40 for SOL40-E3. Customer Service Helpline at 1300 140 140 (AU) and 0800 130 140 (NZ) for more details. The nuts and caps are designed to be unscrewed or tightened by hand or with the special plastic wrench. If necessary a pliers can be used to unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts or caps. Do not place screwdriver in slots on caps and/or tap with achammer.
Replace the Backup Battery
The backup battery (CR2032 coin) keeps the time in case of a power outage. The battery should be replaced annually or after extended periods without power. Replacement batteries can also be ordered using code: BA-CR2032 through your local Puretec dealer.
- Turn off the power to the unit and remove the valve cover.
- Using a non conductive item (like the plastic end of a pen), poke the battery from underneath the battery mount and slide the old battery out.
- Insert the new battery into the battery mount, ensuring is fully seated and in the correct orientation (as shown).
- Replace the valve cover and switch the unit back on.
- Reset the time if needed by following the time programming instructions in this user guide.
Bypass Valve Operation
optional accessory (purchased separately)
- Normal Operation
- Bypass Operation
- Diagnostic Mode
- Shut Off Mode
Troubleshooting Guide
‘Dry’ Reset Procedure
From time to time, the valve may display an error code for various reasons. The first troubleshooting step is to perform a ‘dry’ reset.
| Remove the faceplate, opening the tabs on either side of the valve. This will expose the Power Circuit board with a number of wires connected.
On the bottom right hand corner is a 4 pin adaptor labelled ‘12VAC PWR’, disconnect the adaptor and reconnect after 5 seconds. The valve will then whir twice, and should return to the normal screen.
If the error message is still present, refer to the troubleshooting guide.
---|---
PROBLEM | POSSIBLE CAUSE | SOLUTION |
---|---|---|
No display/blank screen on valve. | A. Transformer not connected. | A. Connect |
transformer.
B. No power at outlet/source.| B. Use working outlet/repair outlet.
C. Switched outlet/improper voltage.| C. Use uninterrupted outlet/ensure
source is
delivering proper voltage.
D. Dead battery.| D. Replace battery (CR2032).
E. Defective transformer.| E. Replace transformer.
F. Defective PC Board.| F. Replace PC Board.
Valve does not display correct time of day.| A. Power outage(s).| A. Reset
time of day, replace battery
(CR2032).
B. Time of day set incorrectly.| B. Reset to correct time of day.
C. Switched outlet.| C. Use uninterrupted outlet.
D. Tripped breaker switch.| D. Reset breaker switch.
E. Defective PC Board.| E. Replace PC Board.
Valve regenerates at wrong time of day.| A. Power outage(s).| A. Reset time of
day, replace battery
(CR2032).
B. Time of day set incorrectly.| B. Reset to correct time of day.
C. Time of regeneration set incorrectly.| C. Reset regeneration time.
D. Control valve set for immediate
regeneration.
| D. Contact Puretec for assistance.
E. Control valve set for delayed and/or
immediate regeneration.
| E. Contact Puretec for assistance.
Time of day flashes on and off.| A. Power outage(s).| A. Reset time of day,
replace battery (CR2032)
and then perform a ‘dry’ reset.
Valve does not regenerate when performing a manual regeneration.| A. No power
to valve.| A. Refer to ‘No display/blank screen on valve’.
---|---|---
B. Broken drive gear or drive cap assembly.| B. Replace drive gear or drive
cap assembly.
C. Broken piston rod.| C. Replace piston rod.
Valve does not regenerate automatically, but does when performing a manual
regeneration.| A. Bypass valve in bypass position/faulty.| A. Turn bypass to
normal operation/replace
bypass.
B. Meter loosely/not connected to PC Board.| B. Connect meter into the three pin connector
labelled METER on PC Board.
C. Restricted/stalled meter turbine.| C. Remove meter and check for rotation or
foreign material.
D. Incorrect programming.| D. Contact Puretec for assistance.
E. Defective meter.| E. Replace meter.
F. Defective PC Board.| F. Replace PC Board.
Hard/Untreated water delivered to service.| A. Bypass valve is in bypass
operation/faulty.| A. Turn bypass to normal operation/replace
bypass.
B. Media is exhausted due to high water
usage.
| B. Check program settings or diagnostics for
abnormal water usage.
C. Fouled media bed.| C. Clean/replace media.
D. Meter not registering/faulty.| D. Remove meter and check for rotation or
foreign material/replace meter.
E. Water quality fluctuation.| E. Test water and contact Puretec for
assistance.
F. No regenerant or low level of regenerant.| F. Refill regenerant tank.
G. Valve fails to draw regenerant.| G. Refer to ‘Valve fails to
draw in regenerant’.
H. Insufficient regenerant level in regenerant
tank.
| H. Contact Puretec for assistance.
I. Leak from seal/spacer stack assembly.| I. Clean/replace spacer stack
assembly.
Control valve uses too much regenerant.| A. Incorrect refill setting.| A.
Contact Puretec for assistance.
B. Incorrect program setting.| B. Contact Puretec for assistance.
C. Valve regenerating frequently.| C. Check for leaking fixtures or system
undersized.
Regenerant being delivered to service| A. Low water pressure| A. Check incoming water pressure – water pressure must remain at minimum of
25 psi
---|---|---
B. Incorrect injector size| B. Replace injector with correct size for
application
C. Restricted/kinked drain line| C. Check drain line for restrictions or debris, or
unkink drain line
Excessive water in regenerant tank.| A. Incorrect program settings.| A.
Contact Puretec for assistance.
B. Plugged injector.| B. Clean/replace injector.
C. Loose/damaged drive cap assembly.| C. Tighten/replace drive cap assembly.
D. Leak from seal/spacer stack assembly.| D. Clean/replace spacer stack
assembly.
E. Restricted/kinked drain line.| E. Check drain line for restrictions or
debris,
or unkink drain line.
F. Plugged backwash flow controller.| F. Clean/replace backwash flow
controller.
G. Plugged refill flow controller.| G. Clean/replace refill flow controller.
Valve fails to draw in regenerant.| A. Plugged injector.| A. Clean/replace
injector.
B. Regenerant piston failure.| B. Clean/replace regenerant piston.
C. Leak in regenerant line.| C. Inspect regenerant line for air leak.
D. Restricted/kinked drain line.| D. Check drain line for restrictions or
debris,
or unkink drain line.
E. Drain line too long or too high.| E. Shorten length and or height.
F. Low water pressure.| F. Check incoming water pressure – water pressure must
remain at minimum of 25
psi.
Water running to drain.| A. Power outage during regeneration.| A. Upon power being restored control will finish the remaining regeneration
time. Reset time of day, replace battery
(CR2032).
B. Foreign material present in valve.| B. Remove drive cap, piston and spacer assemblies. Clean and relubricate components, assemble the valve and run a
manual backwash.
C. Leak from seal/spacer stack assembly.| C. Clean/replace spacer stack
assembly.
D. Piston assembly failure.| D. Clean/replace piston assembly.
E. Loose/damaged drive cap assembly.| E. Tighten/replace drive cap assembly.
Error Code – E1
Control unable to sense motor movement.
| A. Motor not inserted fully into engage position, motor wires broken or
disconnected.| A. Disconnect power, make sure the motor is fully engaged,
check for broken wires, make sure two pin connector is connected to the two
pin connection on the PC Board labelled MOTOR. Connect power and perform a
‘dry’ reset.
---|---|---
B. PC Board not correctly installed.| B. Ensure PC Board is correctly clipped
into drive bracket and perform a ‘dry’ reset.
C. Board unable to read middle reduction gear.| C. Check foil on reduction
gear; clean any foreign material on the foil.
D. Missing/damaged reduction gears.| D. Replace missing gears.
E. Defective PC Board.| E. Replace PC Board.
Error Code – E2
Control valve motor ran too short and was unable to find the next cycle position and stalled.
| A. Foreign material lodged in valve.| A. Clean/replace piston/spacer stack
assembly. Perform a ‘dry’ reset.
B. Mechanical binding.| B. Check piston, spacer stack assembly, drive bracket
and main drive gear interface. Perform a ‘dry’ reset.
C. Main drive gear too tight.| C. Loosen main drive gear. Perform a ‘dry’
reset.
D. Incorrect voltage being delivered to valve.| D. Check voltage of power
source. Perform a ‘dry’ reset.
E. Incorrect programming.| E. Contact Puretec for assistance.
Error Code – E3
Control valve motor ran too long and was unable to find the next cycle position.
| A. Motor failure during regeneration.| A. Check motor connections. Perform a
‘dry’ reset.
B. Foreign material lodged in valve.| B. Clean/replace piston/spacer stack
assembly. Perform a ‘dry’ reset.
C. Drive bracket not correctly installed.| C. Snap drive bracket in correctly.
Perform a ‘dry’ reset.
Error Code – E4
Control valve motor ran too long and timed out
trying to reach home position.
| A. Drive bracket not correctly installed.| A. Snap drive bracket in
correctly. Perform a ‘dry’ reset.
Valve does not indicate that water is flowing.| A. Bypass valve is in bypass
operation/faulty.| A. Turn bypass to normal operation/replace bypass.
B. Meter not connected.| B. Connect meter to three pin connection labelled
MOTOR on PC Board.
C. Restricted/stalled meter turbine.| C. Remove meter and check for rotation
or foreign material/replace meter.
D. Defective meter.| D. Replace meter.
E. Defective PC Board.| E. Replace PC Board.
Warranty
Any claim under this warranty must be made within 6 years of the date of purchase of the product. This product is warrantied to be free of defect of material and workmanship for 6 years from date of purchase. 6 year warranty is 1 year parts and labour, plus 5 years parts only. Excludes consumables. Puretec is renowned for its quality and after-sales support so if you have any issues please call 1300 140 140 (AU) or 0800 130 140 (NZ). To make a warranty claim, contact us directly or the place of original purchase. All costs relating to a warranty claim must be approved by Puretec prior to any work being carried out.
Puretec will pay your reasonable, direct expenses of claiming under this warranty. You may submit details and proof of your expense claim to place of purchase for consideration. The warranty only applies if the product was used and/or installed in accordance with the user guide and/or installation instructions. This warranty is given in lieu of all other express or implied warranties and manufacturer shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law. Applicable to all above, is that the warranties need to be approved by Puretec to ensure product was not incorrectly used, installed or claimed. False and incorrect claims will be pursued at Puretec’s discretion, including chargeable inspection and labour costs incurred. All installation and service work should be completed by qualified tradespeople. Faulty operation due to unqualified persons will result in voided warranty coverage.
Warranty/Australia
This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road, Lonsdale SA 5160, telephone no. 1300 140 140 and email at sales@puretec.com.au. This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Warranty/New Zealand
This warranty is given by Puretec NZ LP, Reg. No 50081773, PO Box 875 Cambridge 3450 NZ, telephone no. 0800 130 140 and email at sales@puretec.co.nz. This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Consumer Guarantees Act. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
CONTACTS
AUSTRALIA
- P 1300 140 140
- E sales@puretec.com.au
- W puretec.com.au
NEW ZEALAND
- P 0800 130 140
- E sales@puretec.co.nz
- w puretec.co.nz
Copyright © Puretec Pty Ltd 2023
ATS5200.103
Licence No. WM 74593
Pro-Switch Pty Ltd
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>