sinope LM4110-ZB Tank Monitor Installation Guide
- June 9, 2024
- sinope
Table of Contents
- sinope LM4110-ZB Tank Monitor
- YOUR TANK MONITOR
- MATERIALS REQUIRED FOR INSTALLATION
- INSTALLING THE BATTERIES AND ACTIVATING THE MONITOR
- MONITOR ACTIVATION
- INSTALLATION OF THE MONITOR ON THE TANK
- CONNECT YOUR TANK MONITOR TO A COMPATIBLE ZIGBEE GATEWAY
- DISCONNECT YOUR TANK MONITOR FROM THE ZIGBEE GATEWAY
- CLEANING INSTRUCTIONS
- RISK ANALYSIS ON POTENTIAL MISUSE OF THE TRANSMITTER
- TECHNICAL SPECIFICATIONS
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
sinope LM4110-ZB Tank Monitor
YOUR TANK MONITOR
MATERIALS REQUIRED FOR INSTALLATION
-
Propane tank
Pre-installed R3D tank gauge Rochester Gaugess -
Fuel tank
FLRG-48 gauge Sinopé
FLRG-48
Model : Part number
- R3D-LP 5-95% 5909S02733
- R3D-LP 10-80% 5909S02772
IMPORTANT
Tanks that do not have R3D gauges can be upgraded. Contact your propane
supplier for details.
INSTALLING THE BATTERIES AND ACTIVATING THE MONITOR
-
Remove the shipping plate.
-
Unscrew the 2 screws using a square / flat screwdriver.
-
Separate the 2 parts of the monitor.
-
Install the batteries in the top part of the monitor.
Note: Install batteries as marked on the battery housing compartment.
WARNING
The installation of the batteries must be performed at a minimum distance of 3
meters (10 feet) from the propane tank.
MONITOR ACTIVATION
-
If you do not have an account yet, download the Neviweb app for iOS or Android to create an account and add your device.
Get the app -
Tap , then select “Add Device”.
-
Follow the steps of the installation wizard.
-
Put the top part of the monitor back on the base and tighten firmly (9 lbs-ft or 12.2 Nm torque required) to make sure the monitor is waterproof.
INSTALLATION OF THE MONITOR ON THE TANK
The monitor can be installed using the magnetic base on several places on the tank. However, it must be cleared from the wall. Also position it so that the filling valve is free.
The tank monitor should be installed away from metal surfaces (aluminum or steel coatings, aluminum railing).
Insert the remote sensor into the R3D remote-ready dial until it snaps into
place. Make sure the dial is clean before installing the remote sensor.
The tank monitor can also be attached with screws (not included) or with
plastic cable ties.
CONNECT YOUR TANK MONITOR TO A COMPATIBLE ZIGBEE GATEWAY
-
Initiate the connectivity session of your compatible Zigbee gateway by referring to its user guide.
-
Connect your tank monitor to the network by briefly pressing the button under the device’s antenna.
-
Once connected, it is possible to check the network status by briefly pressing the button.
Light| Status
---|---
Green light blinks| Connection in progress
Green light on for 10 s| Successful connection
Red light on for 10 s| Connection failure*
-
Refer to the “Support” section of our Website at www.sinopetech.com
- When all your devices are connected, close the connectivity session of your Zigbee gateway.
DISCONNECT YOUR TANK MONITOR FROM THE ZIGBEE GATEWAY
To disconnect your device from the Zigbee gateway, press and hold on the
button under the antenna for 10 seconds.
The LED will flash red 3 times to confirm the disconnection.
CLEANING INSTRUCTIONS
Use a damp cloth for cleaning.
RISK ANALYSIS ON POTENTIAL MISUSE OF THE TRANSMITTER
Risk | Assessment | Mitigation |
---|---|---|
Mechanical damage | Dropping the transmitter and using the cable as a lifting |
mechanism for carrying the transmitter may damage the housing, magnet, sensor
and cable assembly.
The damage may impair the proper operation of the transmitter.| Handle the
transmitter with care using the housing when carrying it for field
installation. Do not use the cable assembly to hold the transmitter. Do not
drop the transmitter and install according to the installation manual.
Water infiltration| Water infiltration can damage the transmitter if the
housing is not well screwed when the batteries are changed.| Both housing
screws must be equally torqued. A torque of 9 Lbs-in (12.2 Nm) is recommended.
It is recommended to alternate between both screws while tightening them.
Electrical malfunction| Incorrect or reverse termination of the battery will
prevent all operations of the transmitter. In addition, the wrong battery type
used may shorten the operational life span of the transmitter.| Install
correctly according to this installation manual and per the markings on the
battery compartment. Also, install batteries of the type as described in the
installation manual.
Reduced transmitter range| Covering the transmitter with any metal apparatus
will reduce the effective transmission range.| Do not cover the transmitter.
TECHNICAL SPECIFICATIONS
-
Power supply
Type: 3 AA lithium batteries (Energizer Ultimate Lithium) Lifespan: 10 years -
Environnement
Indice de protection : IP65
Classification de zone : Classe 1 Division/Zone 2, Groupe D/IIA, T4 -
Operating voltage: 5 VDC nom., 80 mA max
-
Operating temperature: -40 °C to 50 °C (-40 °F to 122 °F)
-
Storage temperature: -40 °C to 50 °C (-40 °F to 122 °F)
-
Relative humidity of condensation: 0 to 100%
-
Altitude: Up to 3000 meters
Transmission
- Protocol: Zigbee 3.0
- Frequency: 2.4 GHz
- Transmission power: +20 dBm
- Receiver sensitivity: -108 dBm
Transmitter Module IC: 5123A-GM210P / FCC ID:QOQGM210P
This device complies wîth lndustry Canada license exempt RSS standard[s].
Operation is subject to the following two conditions:
- This device does not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy, and if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the
equipment OFF and ON, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- lncrease the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Neviweb® is a registered trademark of Sinopé Technologies Inc. in Canada and the United States. Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google Inc.
3-year limited warranty and service
SINOPE TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3-year period from the date of
purchase, under normal use and service, when proof of purchase of such is
provided to the manufacturer. This warranty does not cover any transportation
costs that may be incurred by the consumer. Nor does it cover a product that
has been improperly installed, misused or accidentally damaged. The obligation
of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty, will be to
supply a new unit and this releases the manufacturer from paying the
installation costs or other secondary charges linked to replacing the unit or
the components. No serviceable parts inside the product. Contact Sinope
Technologies.
For more information, visit our Website:
www.sinopetech.com