HERITAGE BATHROOMS SDBN05 Temperature Adjustment Valve
Please leave these instructions with the end user
- Product Code: SDBN05 (D2)
Specifications
Dynamic Water Pressure
-
Min: 0.2 bar
-
Max: 5.0 bar
-
Maximum Static Pressure: 10.0 bar
Inlet Water Temperature
- Cold Water Supply Min: 5°C Max: 25°C
- Hot Water Supply 65°C Recommended
IMPORTANT
The inlet hot water must be at least 10°C above the required blend
temperature.
Inlet Dimension
Tools You’ll Need
Prior to Installation
All products manufactured and supplied by Heritage are safe to use provided
that they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and current
by-laws. For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of
future maintenance. Before installing this product the water supply must be
thoroughly flushed in order to remove any swarf, solder etc. Full access must
be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
This product must not be modified in any way as this will invalidate the
guarantee.
If in doubt, contact a registered plumber, your Local Water Authority or the
Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Cavity Dimensions (mm)
-
Minimum
Fitting Depth: 45mm -
Maximum
Fitting Depth: 75mm -
Concealing Plate
Adjustment Range: 30mm
Pack Contents
Valve Configuration
-
Remove the inlet elbows and filters. Remove the plastic inserts from the valve inlets and insert the flow regulators. Replace the elbows, ensuring the
filters are fitted.
IMPORTANT
If installed in with a combination boiler flow regulators must be fitted.
-
Screw the shrouds valve.
Installation
-
Install suitable batons (if required) into the cavity. Take the finished wall surface into consideration when fitting the valve into the cavity. Mark the position of the valve; drill and plug holes to suit.
-
Secure the valve using the screws supplied (solid walls only) or a suitable alternative.
-
Connect the inlet pipes ensuring the olives are fitted.
-
Plumb your chosen outlets into the valve. Turn on the water supply and check the valve for any leaks.
-
Draw around the concealing plate as a template, measuring in by 10mm to give clearance. Finish the wall surface. Using a silicon sealant, push on the concealing plate and hold firmly until set.
-
Fit the handles and shrouds.
Temperature Adjustment
-
Turn the handle to the maximum temperature setting, then remove it. Turn the shower on.
-
Turn the spindle to increase or decrease the temperature. Check the temperature and adjust until you achieve the desired result
-
Fit the temperature handle back in the maximum hot position.
General Cleaning
Heritage products are made from premium materials, with hand polished, PVD,
EPD or electroplated finishes.
Your product should be regularly cleaned with warm water, a mild pH-neutral
liquid soap, and polished with a soft cloth. Any residues from soap,
toiletries etc. should be rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the
surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges,
steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in
some cloths, so it is also important to avoid leaving cloths on surfaces.
Operation
Wall Outlet Installation
Choose the location for the wall outlet and create a 25-30mm hole in the wall. Ensure your shower accessories have enough reach from that position. Finish the wall surface.
Servicing Intervals
To reduce the build up of lime scale and to ensure this shower works to its
maximum performance we recommend this shower is serviced every 6-12 months
depending on the hardness of your water.
Maintenance – Cartridge Cleaning
-
IMPORTANT Isolate the water supply before starting!
-
Gently remove the concealing plate from the wall.
-
Unscrew shrouds. Remove the cartridges and piston.
-
Remove any O-rings and soak all components in de-scaler and wash off in clean water. Examine all seals and replace if needed. Use WRAS approved silicon based grease on all seals.
-
Reverse the installation steps, ensuring the temperature stop is aligned correctly.
-
Follow the Temperature Adjustment Steps if required.
Troubleshooting
Troubleshooting|
---|---
Symptom| Cause| Remedy
No flow or low flow rate
| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too
low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| Refer to the
specification for the minimum distance required.
Are the water supply pressures balanced?| If pressures are unbalanced, a
pressure reducing valve should be used for optimum performance.
Hot or cold water being drawn off elsewhere causing pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets
when using the shower.
Airlock or partial blockage in the supply pipework.| Flush through pipework
and filters to ensure removal of debris and any airlocks.
Hot/Cold water supply has failed| Check the hot and cold feeds.
The shower will not work if either fails.
Maximum Water Temperature too Hot/Cold| Maximum Water
Temperature needs adjusting.| Refer to the Temperature Setting section to set
your desired maximum temperature.
Outlet Water Temperature too Hot/Cold
| Filter/pipe blockage| Flush through pipework and filters to ensure removal
of debris and any airlocks.
Installtion conditions outside operating parameters.| Refer to the
specification for the minimum distance required.
Hot water temperature is less than 10°C above the required blend temperature|
Adjust hot water temperature or wait for water to reheat if a stored water
system is used.
Instantaneous water not igniting because the water flow rate is too low.|
Increase water flow rate through the system. Refer to the Maintenance section
to clean/check the cartridge and filters for any damage.
Contact your boiler manufacturer.
Instantaneous water not igniting because the water pressure is too low.| Refer
to the specification for system requirements.
Increase water pressure through the system.
Contact your boiler manufacturer.
Only hot/cold water from Shower Valve
|
Inlet water supplies are reversed.
| Check the water inlet connections are the correct way around: Hot on the
left, Cold on the right when viewed from the front. Rework pipework as
necessary.
Filter/pipe blockage| Flush through pipework and filters to ensure removal of
debris and any airlocks.
Water dripping from shower| This is normal for a short time after
using the shower.| This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip, possibly due to the cartridge| Remove cartridge
and clean, refer to the ‘Maintenance’ section before starting any maintenance.
Shower does
not turn on
| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
Our Guarantee
The confidence we have in the quality of our products and services enables us
to offer a free peace-of-mind product guarantee from 2 years up to a lifetime
guarantee against any manufacturing faults, with proof of purchase. In
addition, our attentive customer service team are available to help solve any
problems which may arise quickly and effectively so you can enjoy your
bathroom.
To see the specific guarantee for this product, scan the QR Code or visit the
following URL: https://www.heritagebathrooms.com/service-centre/guarantee
Bristan Group Ltd.
- UK: Heritage Bathrooms, B78 1SG.
- EU: Masco Europe S.à.r.l., 14 Rue Strachen 6933 Mensdorf, Luxembourg.
Customer Service: +44330 026 8503
References
- Water Regulations Approval Scheme Ltd - Approvals Directory
- Heritage® Guarantee | Service Centre | Heritage®
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>