The Q-NEX Networked Media Processor integrates the Ethernet connection into the device control system, allowing users to remotely control the device. It is mainly designed for assisting school’s IT admin to well manage various electronic facilities in a school, and freeing teachers from complicated operation of a multimedia classroom.
2.Components of NMP

Networked Media Processor*1

Wireless Mic*1

Returnstar Interactive Technology Group Co., Ltd.

Control Panel*1

Touch Panel*1 (Optional) -1-

2.1 NMP front view

2.3 Control panel features

Wireless microphone channel RF: wireless microphone radio frequency indicator DOWN: switch channel down UP: switch channel up AF: wireless microphone audio frequency indicator POWER-VOL: wireless microphone volume knob
2.2 NMP rear view interfaces

RJ45 3* 3HDMI matrix Display power supply Electronic projection screen
power supply NMP power supply External device Single pole
double throw power relay Power fuse Electric lock control
-2-

External speaker output Audio output Audio input Mic output Mic input Smart touch USB ports
(1&2 for USB Host, 3 for USB Device) USB2.0 ports IR learner port Control Panel connection RS232

Computer: indicator on means HDMI out A switched to HDMI in 1, recommend PC as input.
Visualizer: indicator on means HDMI out A switched to HDMI in 2, recommend visualizer as input
HDMI 3: indicator on means HDMI out A switched to HDMI in 3
Display: indicator on means power on the device connected to Display
Light: indicator on means power on the device connected to External, recommend light
Main power: indicator in blue/red means power on/off MIC: to control volume of mic when the indicator is on, to
control volume of speaker when the indicator is off VOL.-: the indicator is on when volume is down to the least VOL indicator light:more indicators on as volume increases IC Card Areatap the IC card to unlock the panelcan
power on NMP when it’s off VOL.+:the indicator is on when volume is up to the max. Mute: indicator on means the speaker is mute Lock: indicator on means the panel is locked
-3-

2.4 Touch panel features
-4-

2.5 Handheld mic features
Communication channel

2.6 Lapel mic features

Frequency

Current frequency
Battery status

2.7 Pairing Touch Panel with Wireless Mic
Pairing steps: 1. Power on microphoneand enter pairing mode. For Handheld microphone: Press power button 3 times to enter pairing mode

Battery status

Power button

LCD screen Power
a.Press once to power on, long press to power off.
b.When the handheld microphone is on, press the power button to switch to the next channel.
c.When the handheld microphone is on, continuously click the power button three times to enter the pairing mode.

Lapel mic port

Power button

Antenna

LCD screen

Volume adjust

Channel pairing: press three

times to enter the pairing mode, the LCD screen

displays IR—; press to

switch channels

For Lapel microphone ­ press round button 3 times to enter pairing mode

-5-

-6-

-7-

2. Then click on touch Panel or swipe a IC card to turn on NMP, the microphones will automatically pair with the receiver built in the NMP.

3. Get ready before installation
3.1 Require an Admin account of Q-NEX Console from Q-NEX team. Log in https://mg.qnextech.com/. and bind in NMP devices to a created virtual organization in the system for identification.
3.2 Prepare the power cable for power out of Display: · Uncovered copper wire length>=10mm · Wire cable with insulation paste>=25mm · Tighten the single copper wire

When it is successfully paired, the indicator in front of NMP will turn green as below:

Note: 1) Don’t turn on Q-NEX NMP before setting the wireless microphones in pairing mode, otherwise, the pairing process will fail! 2) Both handheld and lapel microphones are paired with NMP accordingly already before leaving factory, so you DON’T have to pair them when it is FIRST TIME to unbox Q-NEX NMP.

3.2.1 Pry open the shrapnel inside the hole with a screwdriver, in the meantime, insert the thread. Release the screwdriver, the thread will be fastened inside the WAGO. At last, pull the wire to check if it is fixed tightly.

3.2.2 After placing the wires, use the Wire Protection Clip to fasten. Then put on the Shell Base and Shell Cover.

3.3 Prepare the power cable for SPDT switch of External:

Device

L

L

N

Power

3.4 RS232 connection for projector:

For the other end, wiring according to the wiring instructions of the controlled equipment.
G Ground Rx Receive Tx Transmit

3.5 Speaker connection

+ red – black – black + red

3.6 Electric lock connection Please connect the required interface according to your electronic lock type.
+: Power output 12V800mA -: Power ground (negative level) I: Door switch interface D: Door lock status interface C: Relay common end, load capacity DC3A/30V O: Relay normally open, load capacity DC3A/30V

-8-
4. Wiring and setup
Please follow the instructions below to connect the cables
Note: Installation and repair should only be performed by authorized personnel.
4.1 Basic installation
Connect the NMP power cable to “POWER IN”.
For Control Panel
Connect the control panel to the NMP “PANEL” port:
If the power indicator on control panel is red, that shows the connection is well done. Now touch the main power button, the power indicator light turns in blue, which means it is booted successfully.

-9-

-10-

-11-

For Touch Panel
(Connect to NMP with CAT Cable)
(1) Screw the wall mount bracket to the desktop stand.
(2) Connect the Touch Panel to network and power up. There are three ways for connection:
· Connect Touch Panel to NMP by network cable, and power through 12V adapter.
· Connect Touch Panel and NMP to the same switch, and power Touch Panel through 12V adapter.
· Connect both Touch Panel and NMP to one PoE switch, then no power supply is required for Touch Panel.

(3) Fasten the wall-mounted bracket into the slots of Touch Panel and make sure it is fixed.
(4) Initial settings
Make sure that NMP is connected to the network (refer to NMP Quick Guide). Log in to the Q-NEX Dashboard -Devices-Processor Manager and check the IP address of this NMP.

Note: · The LAN ports NMP 211-G don’t support POE. · Touch Panel must be on the same LAN as NMP.

It will enter the homepage of Touch Panel after connecting successfully.

Warning
Do not power Touch Panel through adapter and POE at the same time, it will cause Touch Panel to be short-circuited and burned. This kind of damage is not covered by the warranty.

Input the IP address on the Touch Panel and click Connect.

-12-

-13-

-14-

-15-

Connect NMP to the Ethernet :
If the yellow and green LED light of Ethernet port is flickering, which means the network connection is successful.
Add NMP to Console By web Log in to Q-NEX dashboard (check your email for the initial administrator account / password), enter the Device/Processor Manager page, and click on the “Add Device” to add a new NMP into the system:
-16-
Note: Keep the gross output power of both “Display”and
“Screen” port under 1,200 W. The current-carrying capacity of the”External”switch
should not exceed 1200W Power control of control panel or touch panel:
SCREEN: Replace the plug of projection screen with WAGO connector, connect to SCREEN port. (Note: Projection screen only)
UP
N
DOW N
-20-

Put in a device name (can be “Classroom One”, for example) and device ID indicated on NMP (product S/N). Select a group where the NMP is classified (for example, “Grade One” in a school). Set the startup linkage parameters as required, and click Save:

Add NMP to Console By APP

1

Scan the QR code on the NMP through the scan button on the device page and follow the steps to add the new NMP.

2

3

When the NMP device info is successfully submitted, and verified by Q-NEX system online, the “Status” will turn green.

-17-
Projection screen up and down can be controlled via Q-NEX Console, mobile APP or Touch Panel after successful connection.

-18-
Both control panel and touch panel only control the input source switching of HDMI out A, press the button to switch directly to the corresponding channel, and the signal light is on.

4.3 Video matrix switch
NMP supports HDMI output to three displays. Connect display devices, like TV, projector, and IFP, to HDMI OUT, and connect HDMI devices, such as PC, document camera, IQShare etc., to HDMI IN.

Please operate on Q-NEX APP or Q-NEX Console to switch the input source of HDMI out B and HDMI out C.

4.2 Power control
DISPLAY: Replace the plug of the display devices (projector and projection screen, TV, IFP, etc.) with WAGO connector, Connect the WAGO connector to the DISPLAY port of NMP.
To realize power control of devices with RS232 connection (e.g., projector), please connect the device through the RS232 of NMP as well.
EXTERNAL: For other devices that need to control power, such as lights, please connect the device to the EXTERNAL power switch control port according to the installation of a single-pole double-throw switch:

SPDT switch L

N
Warning: Do not input power to “External”, otherwise it will cause NMP irreparable fatal failure.

Light

-19-

Touch USB: Route touch signals from different HDMI inputs to a touch display (should be HDMI A). For example, if an interactive flat panel (as HDMI A) can work with a PC for 10 touches, but only one touch with a document camera, then when switching signal from PC to document camera, the interactive flat panel will accordingly enable 10 touches to one touch.

Note: The Touch USB feature works only when the touch display is compatible with the input devices for touch.

Input device

Touch USB HDMI

Touch USB Display

HDMI

HDMI Input device

Touch USB

4.4 Audio control
NMP has a built-in power amplifier, 2*(40w+40w), that can be connected to passive speakers. Replace the speaker cable with a Phoenix audio connector and plug into the speaker interface. Up to two pairs of passive speakers can be connected.

-21-

-22-

-23-

Volume adjustment or mute can be operated via control panel or touch panel. Sound muted when MUTE lights up.
Touch panel can also adjust treble and bass, switch the audio source of HDMI out A as well.

Through 3.5mm line in, NMP can support devices with audio output such as mobile phones, operation can be done via control panel-AUDIO.

4.5 Microphone control
4.5.1 Wireless microphone connection:
Put the wireless microphone close to the NMP and turn it on. After frequency pairing is successful, there will be a beep and the corresponding MIC indicator on the front of the NMP will light up.
4.5.2 Wired microphone connection: The wired microphone can be connected to the NMP through a 6.5mm mic cable. Sound of wired and wirless microphone get mixed and output.
4.5.3 Microphone volume adjustment:
For Control Panel The microphone is under control when it lights up. At this time,the operations of increasing the volume, decreasing the volume and muting are only for the microphone.

For Touch Panel Touch panel can adjust microphone volume, treble and bass.
4.6 Air-conditioner control
Connect infrared transmitter to “IR” port of NMP, and aim the transmitter at the air conditioner, and ensure there should be no blocks in between the transmitter and the air conditioner.

-24-
4

Select infrared control edit module of a certain NMP to identify

the new A/C control code, follow the instruction as below

Click the “New A/C control code” then the “start ”

button

While analyzing, aim the A/C remote control at the infrared

learning hole on NMP, and press the power button

After identified successfully, fill in the A/C brands, models,

and save Select the

air-conditioner

control

code

from

pull-up

menu1,

and save.

Now control the air conditioner on Q-NEX Console or touch

panel.

-25-
5 Q-NEX Console

2

3

5 Touch Panel

Login Q-NEX console -> Dashboard -> Devices -> Processor manager.

-26-

4.7 IR remote control settings

IR remote control module is available for unrecognized air

2

conditioners or other devices using infrared remote control.

Connect infrared transmitter to “IR” port of NMP, and aim the

transmitter at the device, and ensure there will be no blocks in

between the transmitter and the device.

Login Q-NEX console -> Dashboard -> Devices -> Processor manager.

Select infrared control edit module of a certain NMP to learn the new remote control code, follow the instruction as below: click the “New remote control code” Choose the type of IR control device Click “start to learn” While analyzing, aim the remote control at the infrared
learning hole on NMP, and then press the function button After identified success, add information of control code and
save. Select the target remote control code, save and done. Rmote control on Q-NEX Console or touch panel.
1

-27-
3
6

-28-

-29-

-30-

-31-

7 Q-NEX Console 7 Touch Panel
-32-

5. Common problems and solutions
Problem: The microphone button will flash when you long press it. It means entering the pairing state of the WX-U32 microphone. Solution: It is non-fault problem. No need to operate, just wait a few seconds and use it as normal.
If you encounter any problems during installation and use, please contact us: info@qnextech.com

As of the date of manufacture, the product has been tested and found to comply with specifications for CE marking.
-33-

www.QnexTech.com info@QnexTech.com 6th Bldg. High-Tech Base. Fuzhou Fujian Prov. China
-34-

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals