i Connector – SMART IOTA GATEWAY THC

deviteq STHC iConnector Smart IoT Gateway - 1 THC is a Smart IoT Gateway, aka i Connector, a main component in any IoT application. i Connector has a role to connect the real World’s things like sensors, meters, ,machines…to server system for data logging, data analytics, monitoring & controls…i Connector support multiple Industrial Field bus like Modbus, Ethernet IP, Proficient, C Clink, Wireless sensor network…It connects to server system via LAN/WAN as Ethernet, WiFi or Cellular.
3-IN-1 DEVICE
i Connector is a 3-in 1 device, comprises Data logger + Logic Controller + Internet Gateway
NO NEED PROGRAMMING
Don’t need to learn any Programming language, just configure it remotely by Globalists platform
JUST 2-STEP FOR USING
Just install and configure it remotely on Globalists, then you can start use it!
** MULTIPLE FIELD BUS PROTOCOLS
Support multiple Field bus protocols like Modbus, Ethernet IP, Proficient, Clink…
SINCE 2014!**
Industrial customers have been using i Connectors since 2014 because of its quality!

i Connector – SMART IOTA GATEWAYdeviteq STHC iConnector Smart IoT Gateway -
2

SPECIFICATION

Host Communication Cellular type| LTE Cat 4, 3G-Dual band (2100/900) or LTE Cat M1/NB1 with Global band (B1, B2, B3, B4, B5, B8, B9, B10, B12, B13, B17, B18, B19, B20, B25, B26, B27, B28, B66 ) and 2G-Quad band fall back, standard internal antenna, optional external antenna
---|---
Host Communication Ethernet type| 01 x RJ45 port, Mbps
Host Communication WiFi type| 802.11b/g/n, 2.4Ghz,internal antenna
GPS| option, only available on GARS version or 3G-Pena band version
Host communication supports| TCP/IP, UDP/IP, FTP, HTTPD, SNIP…
Field bus communication| Modulus x 01 port, 31 slaves, max 19.2 kbps
Vietnam Type Approval Verification| QC 54:2011/BUTT, QC 15:2015/BUTT (DAVIT B00122019)
Optional| Integrated wireless co-coordinator with external antenna or internal antenna
Optional| Internal buzzer (to replace Relay 1)
Power supply| 7..48VDC, avg 200mA, peak 1.5A
Back-up battery| Lithium-ion for cellular versions
On-board memory & sensors| MB Flash, PCB temperature sensor
Electrical connectors| M12, 4-pin, coding A or 9mm Power Plug and USB port
SIM slot| 01 x micro-SIM (cellular versions only)
Included accessories| mounting bracket for wall mount
Operating Temperature/Humidity| -20 .. + 60 deg C / 95%RH, non-condensing
Housing/Protection| Aluminum+Poly carbonate. IP67 protection.
Dimension| H106xW73xD42
Net weight| 190 grams
Relay outputs| 02 x relay SPST NO contact, 125VAC@0.3A or 24VDC@1A (depends on item code)

i Connector 4G CAT WITH WIRELESS CO-COORDINATOR  THC-MISGOVERN-WS433-CL-04 TYPICAL APPLICATIONdeviteq STHC iConnector Smart IoT Gateway -
4

CONNECT WIRELESS SENSORS TO GLOBIOTS Platformdeviteq STHC iConnector Smart
IoT Gateway - 5 PIN ASSIGNMENT & WIRING BUILT-IN WIRELESS CO-COORDINATORdeviteq STHC iConnector Smart IoT Gateway -
6 DIMENSION DRAWINGS OF STANDARD VERSION
(Unit: mm)deviteq STHC iConnector Smart IoT Gateway -
7 DIMENSION DRAWINGS BUILT-IN WIRELESS CO-COORDINATOR VERSION
(Unit: mm)

deviteq STHC iConnector Smart IoT Gateway - 8

ORDERING INFORMATION

ITEM CODE DESCRIPTIONS
STHC-ISG02DB-NC i Connector 3g Dual-Band, internal antenna, with 02 relays,

no M12 cables
STHC-ISG02DB-WS433-CL-04| i Connector 3g Dual-Band, internal GSM antenna, RS485/MODULUS with built-in wireless co-coordinator, external antenna 0 dbi with M12-Male connector
STHC-ISGWF-WS433-CL-04| i Connector WIFI, internal WIFI antenna, RS485/MODULUS with built-in wireless co-coordinator, external antenna 0 dbi with M12-Male connector
STHC-SWEETISH-WS433-CL-04| Smart Out-of-Box IoT Gateway, i Connector, Data logger + Controller + Gateway, WIFI 2.4ghz and Ethernet 10mbps, with Wireless Sub-GHz RF receiver
SIMMOBI-3G| Mobifone Data SIM CARD, only SMS receiving mode
SIMMOBI-10K-01Y| 12-month data plan for SIM CARD, unlimited data, GPRS/EDGE/UMTS/HSPA
SPECIAL ORDER
STHC-ISG04A-WS433-CL-04| i Connector 4G Cat 4, Asia bands, internal GSM antenna, RS485/MODULUS with built-in wireless coordinator, external antenna 0 dbi with M12-Male connector
STHC-ISGM1-NB1-2G-NC| i Connector CAT M1, NB1, 2G, Global bands, internal antenna, with 02 relays, no M12 cables
STHC-ISGM1-NB1-WS433-CL-04| i Connector CAT M1, NB1, 2G, Global bands, internal antenna, with built-in wireless co-coordinator, external antenna 0 dbi with M12-Male connector and with M12-F to DC jack power cable
STHC-ISG02DB-WS433-CL-05| i Connector 3G Dual Band, internal GSM antenna, integrated wireless co-coordinator with Glasnost external antenna 0 dbi, 9mm DC Power Jack and USB port for configuration
STHC-ISG02DB-WS433-CL-06| i Connector 3G Dual Band
, internal GSM antenna, integrated wireless co-coordinator with internal antenna , 9mm DC Power Plug and USB port for configuration, internal buzzer
STHC-ISG02-NC/GPS| i Connector 3G Penta Band with GPS, internal antennas, with 02 relays, no M12 cables
STHC-ISG02DB-NC/EXTANT| i Connector 3G Dual Band, SMA connector for external GSM antenna (order external antenna separately), no relay, no M12 cables
STHC-ISG02-NC/GPS/EXTANT| i Connector 3G Penta Band with GPS, SMA connectors for external GSM/GPS antennas (order external antennas separately), no relay, no M12 cables
STHC-ISG02-WS433-CL-04| i Connector 3G Penta Band, internal GSM antenna, RS485/Modulus with built-in wireless co-coordinator, external antenna 0 dbi with M12-Male connector
ACCESSORIES
RS485-FM12-USB-1| RS485/USB multi-purpose Configuration cable with connector m12 male, female and flying leads, with Power adapter 12VDC/2.0A
EXANT-JCG008| IP67 GSM Antenna for Cellular i Connector with SMA connector, without GPS
EXANT-JCB008L| IP67 Combination GSM+GPS Antenna for Cellular i Connector with SMA connectors, with GPS
2M-MM12CAB4x0.25| M12 4pin Male assembly connector with Soldering terminals and coding A and Control Cable Cu/PVC/OS/PVC 4×0.25mm2, L=2m, Rohs, Shield 80%
2M-FM12CAB4x0.25| M12 4pin Female assembly connector with Soldering terminals and coding A and Control Cable Cu/PVC/OS/PVC 4×0.25mm2, L=2m, Rohs, Shield 80%
5M-MM12CAB4x0.25| M12 4pin Male assembly connector with Soldering terminals and coding A and Control Cable Cu/PVC/OS/PVC 4×0.25mm2, L=5m, Rohs, Shield 80%
5M-FM12CAB4x0.25| M12 4pin Female assembly connector with Soldering terminals and coding A and Control Cable Cu/PVC/OS/PVC 4×0.25mm2, L=5m, Rohs, Shield 80%
10M-MM12CAB4x0.25| M12 4pin Male assembly connector with Soldering terminals and coding A and Control Cable Cu/PVC/OS/PVC 4×0.25mm2, L=10m, Rohs, Shield 80%
10M-FM12CAB4x0.25| M12 4pin Female assembly connector with Soldering terminals and coding A and Control Cable Cu/PVC/OS/PVC 4×0.25mm2, L=10m, Rohs, Shield 80%
Notes|
Purchase M12-female cable to power and RS485 connecting for i Connector
** Purchase M12-male cable for using Relays port
*** Purchase configuration cable RS485-FM12-USB-1 for off-line configuration of i Connector

DAVITEQ TECHNOLOGIES INC
No.11 Street 2G, Nam Hung Vuong Res., An Lac Ward, Binh Tan Dist., Ho Chi Minh City, Vietnam
+84.28.6268.2523 / 6268.2524
info@daviteq.com
www.daviteq.com
OCT-2022 

Doc No: STHC-DS-EN-13

Documents / Resources

| deviteq STHC iConnector Smart IoT Gateway [pdf] Owner's Manual
STHC, iConnector Smart IoT Gateway, STHC iConnector Smart IoT Gateway, Smart IoT Gateway, IoT Gateway, Gateway
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals